Model: SP-250-XXX Total Power 250 Watts Input Voltage 90-264 VAC Outputs Single - 250 Watts - High Density- 1U Profile 5 x 3.3 x 1.5 SPECIAL FEATURES - Power Factor and Harmonic Current Correction - Active Power Factor Correction - Wide Range Input ELECTRICAL SPECIFICATIONS - Remote Sense Input Specifications - UL, cUL, and DEMKO Input Range90-264 VAC - CE Compliant Frequency47-63 Hz - Low profile height fits 1U constraints EMI filterEN55022 Class B, FCC - Custom Modifications Available Part 15 Inrush Current 32A 230 VAC ENVIRONMENTAL SPECIFICATIONS Input Current..2.9 0.95A Humidity: Up to 95% non-condensing Isolation..4242 VDC (Input to Output) Storage Temperature: -40 to +85C Efficiency..80% 120 VAC Active PFC.0.99 Temperature coefficient: 0.01% / C Switching Frequency..134 KHz Leakage<300uA Ambient Operating Temperature: -40 to +60 C Continuous duty, full rating. Derate linearly to 50% of Output Specifications full rating at +85C. DC OutputMaximum continuous output power 250 Watts with 10-CFM fan cooling. 100 Watts Cooling: 250 Watts with 10 CFM forced air-cooling and convection cooled. 100 Watts convection cooled. Line Regulation0.5 % SAFETY APPROVALS UL 60950 Load Regulation1% CUL 60950 DEMKO EN60950 Ripple and Noise1% Pk to Pk Transient Response.2% Maximum deviation returns to initial condition in 1msec max. Autec Power Systems, Inc. Tel: 805-522-0888 Fax: 805-522-8777 Web site www.Autec.com e-mail: autecsales autec.com Model: SP-250-XX OVERALL MECHANICAL DIMENSIONS U-Bracket Construction ELECTRICAL SPECIFICATONS (cont.). 5L x 3.3W x 1.5H Long Term Stability0.01% after 20 minutes (127mm L x 83.82mm W x 38.1mm H) warm-up. (See attached outline drawing) Hold-Up Time..20 msec minimum OVP..Set at 115% to 135%. PIN ASSIGNMENTS Latching method. AC must be recycle to restart the See attached In/output Rating and Pin Assignment Sheet unit. CONNECTOR Short-circuit Protection..The unit will Input Molex 26-40-4050 withstand a continuous short without damage. It will automatically return to regulation upon Output Molex 26-40-4120 removal of the short. NOTES Overload Protection..The overload - Specifications subject to change without notice. protection feature will reduce the output voltage to - All dimensions in inches/mm a safe dissipation level when the output power - Warranty: 1 year rating exceeds 125% of maximum rated power. - Weight: 1.25 lbs. The unit will automatically return to regulation upon removal of the overload. Voltage/Current Rating Chart Part Number Voltage Minimum Maximum SP-250-090 +9.0V 0A 27.8A SP-250-120 +12.0V 0A 20.8A SP-250-150 +15.0V 0A 16.7A SP-250-200 +20.0V 0A 12.5A SP-250-240 +24.0V 0A 10.4A SP-250-280 +28.0V 0A 8.9A SP-250-360 +36.0V 0A 6.9A SP-250-480 +48.0V 0A 5.2A SP-250-580 +58.0V 0A 4.3A *Other voltages are available Autec Power Systems, Inc. Tel: 805-522-0888 Fax: 805-522-8777 Web site www.Autec.com e-mail: autecsales autec.com