V11 TRH70A SERIES 70W SWITCHING ADAPTER Features * Universal Input Range 90~264VAC * Meets EN55032 Class B and CISPR/FCC Class B * Continuous Short Circuit Protection * Over Voltage Protection * Meet CoC Tier 2 & DoE Level VI * No load Power Consumption<150mW * Approved IEC62368-1, UL62368-1, EN62368-1 (Output Cable Length1800mm) (TRH70A120:Output Cable Length720mm) (TRH70A150:Output Cable Length1220mm) (TRH70A180, TRH70A190: Output Cable Length1800mm 16AWG) Ordering information TRH70XXX - E XX -XX Model No. DC Plug Type OVP DC Cable Length and Type 01: 720mm 02: 1220mm 03: 1800mm 11: 720mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 16AWG / UL1185 FOR 12V,15V,18V,19V * 18AWG / UL1185 FOR 24V,28V,36V,48V OUTPUT OUTPUT RIPPLE & VOLTAGE LINE LOAD AVERAGE VOLTAGE CURRENT NOISE ACCURACY REGULATION REGULATION EFFICENCY min. MODEL NOTE 1 NOTE 2 NOTE 3 NOTE 4 NOTE 5 TRH70A120 12V 5.80A 1% 2% 1% 4% 89% TRH70A150 15V 4.65A 2% 1% 3% 89% 1% TRH70A180 18V 3.90A 2% 1% 2% 89% 1% TRH70A190 19V 3.70A 2% 1% 2% 89% 1% TRH70A240 24V 3.00A 2% 1% 2% 89% 1% TRH70A280 28V 2.50A 2% 1% 2% 89% 1% TRH70A360 36V 2.00A 1% 2% 1% 2% 89% TRH70A480 48V 1.50A 1% 2% 1% 2% 89% Specifications are subject to change without notice. 1 V11 Specifications TRH70A Series Derating Curve INPUT SPECIFICATIONS: Voltage ..................................................................... 90~264Vac Frequency ...... 47 to 63Hz Input Current ...............................1.5A max. Inrush Current ..................... Cold Start 25 100A max. 240Vac Leakage Current ..... 3.5mA max. OUTPUT SPECIFICATIONS: Hold-up Time 8ms typ. 115Vac Short Circuit Protection . Continuous(Auto Recovery) Over Voltage Protection .. TVS Component to Clamp Temperature Coefficient ............................ 0.05%/ GENERAL SPECIFICATIONS: NOTE: Isolation Input to output = 3000VAC 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Operating Temperature .............................. -20 ~ 70 (see derating curve) Ripple & Noise measuring 20MHz BW. Storage Temperature .................. -20 ~ 85 2. Voltage setpoint at 60% full load. Humidity ................ 93% RH max. Non condensing 3. Line regulation measured from 100Vac to 240Vac full load. Cooling . Natural Convection 4. Load regulation measured from 60% to full load and from 60% to Switching Frequency .. 65KHz Typical 20% load (60% +/- 40% load). 5. Average Efficiency measured at 25%,50%,75%,100% load and input MTBF MIL-HDBK-217F, GB, at 25 /115VAC . 200Khrs min. Altitude 5000m voltage is 115Vac / 230Vac Dimensions ... 4.724x2.047x1.220 inches (120.00x52.00x31.00mm) Weight 300g AC Inlet .. IEC320/C14 SAFETY AND EMC: Emission and lmmunity EN55032 Class B, FCC Part 15 Class B EN61000-6-3,EN61000-3-2,EN61000-3-3 EN55024, EN61204-3, EN61000-6-1 Safety Class I, IEC62368-1/60950-1, UL62368-1/60950-1 EN62 3 68- 1/ 60 95 0- 1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 DC Plug type: V+ ) V- DC Plug :Right Angle(5.52.1) L12mm 18AWG1800mm Typical at 25C, nominal line and 75% load, unless otherwise Specified 2