Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Description Single pole thermal circuit breaker with press-to-reset, tease-free, trip-free, snap action mechanism. Type 2-5000 is available with optional manual release (-H), type 2-5700 can be supplied as a push-push switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset configuration M-type when fitted with manual release -H S-type with push-push operation). Fitted with flange or threadneck for panel mounting. Options include an additional unprotected circuit tap (-A3). Approved to CBE standard EN 60934 (IEC 60934). Typical applications 1 Motors, transformers, solenoids, battery chargers, power supplies, 2-5000-... 2-5700-... appliances, machinery, extra low voltage systems. Ordering information Technical data Type No. For further details please see: www.e-t-a.de/ti e 2-5000 flange mounting Voltage rating AC 250 V DC 28 V 2-5700 threadneck panel mounting (UL: AC 250 V DC 50 V) Threadneck design type 2-5700 only Current rating range 0.05...25 A iG1 moulded threadneck 3/8-27UNS-2A with metal hexnut and plastic knurled nut (hardware bulk shipped with 5 pcs plus) Typical life AC 250 V / DC 28 V: iG2 moulded threadneck M12x1 with metal hexnut and plastic 0.05...16 A 5,000 operations at 2 x I , inductive N knurled nut (hardware bulk shipped with 5 pcs plus) 17...25 A 5,000 operations at 2 x I , resistive N Terminal design Ambient temperature -20...+60 C (-4...+140 F) P10 blade terminals 6.3-0.8 mm (QC .250) Insulation co-ordination rated impulse pollution K10 screw terminals M4x6 (IEC 60664 and 60664 A) withstand voltage degree Manual release (optional) 2.5 kV 2 H manual release facility (type 2-5000 only) reinforced insulation in operating area DD push to release/push to reset (type 2-5700 only) Current ratings Dielectric strength 0.05...25 A (IEC 60664 and 60664A) test voltage operating area AC 3,000 V 2-5700 - iG1 - P10 - DD - 8 A ordering example Insulation resistance > 100 M (DC 500 V) Interrupting capacity I 0.05...2.5 A 8 x I cn N Please be informed that we have minimum ordering quantities to be observed. 3...5 A 20 x I N 6...12 A 200 A (higher interrupting capacity Preferred types available to special order) 13...25 A 300 A Interrupting capacity I U Preferred types Standard current ratings (A) N N (UL 1077) 0.05...20 A AC 250 V 2,000 A 0.05...25 A DC 50 V 2,500 A 1 2 3 4 5 6 8 10 12 15 16 20 25 (higher values upon request) x x x x x x x x x x x x x 2-5700-IG1-P10- Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 x x x x x x x x x x x 2-5700-IG1-P10-DD Vibration 8 g (57-500 Hz) 0.61 mm (10-57 Hz), x x x x x x x x x x x 2-5700-IG2-P10- to IEC 60068-2-6, test Fc, 10 frequency cycles/axis x x x x x x x x x x x 2-5700-IG2-P10-DD Shock 25 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, Approvals to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Authority Standard Rated voltage Current ratings Mass approx. 29 g VDE IEC/EN 60934 AC 250 V 0.05 A25 A DC 28 V 0.05 A25 A UL UL 1077 AC 250 V 0.05 A20 A DC 50 V 0.05 A25 A CSA C22.2 No 235 AC 250 V 0.05 A20 A DC 50 V 0.05 A25 A CQC GB 17701 AC 250 V 0.05 A25 A DC 28 V 0.05 A25 A 1816 www.e-t-a.de 1Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Dimensions Installation drawings 2-5000-P10 2-5000-P10 operating area 9.5 13.5 .374 .531 A A 1 14 32 14 32 mounting area 19.8 14.5 .780 .571 31 blade terminal DIN 46244-A6.3-0.8 2-5700-P10 1.22 (QC .250) current rating in A operating area 5 40 A 1.57 50 1.97 2-5700-P10 14 32 3 / 8 mounting area 1 1 3 iG1= / -27UNS-2A tightening torque max. 1 Nm 8 .039 .039 iG2=M12x1 tightening torque max. 1.5 Nm 6.5 .256 Standard current ratings and typical internal resistance values A Current Internal Current Internal rating (A) resistance () rating (A) resistance () 0.05 280 3 0.1 14 32 0.08 100 3.5 0.06 blade terminal 0.1 110 4 0.06 DIN 46244-A6.3-0.8 14.5 19.8 (QC .250) .571 .780 0.2 29 4.5 0.05 29 1.14 0.3 14 5 0.05 D-shaped threadneckcurrent rating in A for standard (-DD version without push button marking) 0.4 7 6 0.02 mounting hole 0.5 4.9 7 0.02 5 0.6 3.4 8 0.02 0.7 2.5 10 < 0.02 SW 14 .551 0.8 1.8 12 < 0.02 iG1=9.6-0.1 iG2=12.2-0.1 1 1.2 13 < 0.02 iG1=.378-.004 iG2=.480-.004 1.2 0.8 15 < 0.02 1.5 0.6 16 < 0.02 1.8 0.4 20 < 0.02 Terminal design 2 0.3 22 < 0.02 2.5 0.2 25 < 0.02 -K10 14 32 flat head screw M4x6 ISO1580 mm tightening torque 1.2 Nm This is a metric design and millimeter dimensions take precedence ( ) inch 2 www.e-t-a.de 1816 10.4 iG1=8.8 .409 OFF 22.5 iG2=11.3 5 iG1=.346 .886 .197 iG2=.445 ON 16.5 .650 10.4 46.5 10 1.83 .394 .409 4.5 10.4 12.2 ON .177 .409 .480 18.5 44 18.2 OFF .728 1.73 .717 7 .276 iG1=8.9-0.1 iG2=11.5-0.1 iG1=.350-.004 iG2=.453-.004 25 .984 25 .984 max. 2.5 max. 2.5 max .098 max .098