Product Information

BC190/820

BC190/820 electronic component of Fluke

Datasheet
Battery Chargers Switch Mode Power Supply

Manufacturer: Fluke
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Shipping Restricted
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Chemistry
Output Voltage
Termination Style
Series
Brand
Number Of Batteries
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1273185 electronic component of Fluke 1273185

HEAVY DUTY TEST LEAD SET
Stock : 1

1547885 electronic component of Fluke 1547885

Fluke METER CASE,LEATHER,LARGE
Stock : 1

1576734 electronic component of Fluke 1576734

Fluke FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS
Stock : 1

1610115 electronic component of Fluke 1610115

AC280 Suregrip Hook Clips
Stock : 0

1LAC-A electronic component of Fluke 1LAC-A

LOW VOLTAGE DETECTOR AMERICAS PACIFIC AVAILABLE IN 12 PA
Stock : 0

114519 electronic component of Fluke 114519

AC/DC CURRENT PROBE, SCOPEMETER(R)
Stock : 1

1503 electronic component of Fluke 1503

Insulation Resistance Testers
Stock : 0

1630 electronic component of Fluke 1630

Fluke 1630 Earth Ground Clamp Meter
Stock : 1

190-102/AM electronic component of Fluke 190-102/AM

Oscilloscope (DSO) + DMM - 2 Ch, 100 MHz -- 6" Color TFT LCD -- 8 bit, 1.25Gs/S Portable Scopemeter® ...
Stock : 1

1623-2-KIT electronic component of Fluke 1623-2-KIT

Basic GEO Earth Ground Tester Kit
Stock : 1

Image Description
FLK-VT04-CHARGER electronic component of Fluke FLK-VT04-CHARGER

Battery Chargers POWER SUPPLY,USB SOCKET PLUG & GO 5VDC 1 AMP 5 W - REPLACEMENT
Stock : 0

GC220A24-R7B electronic component of Mean Well GC220A24-R7B

Battery Chargers 217.6W 27.2V 8A Battery Charger
Stock : 18

PA-120N-13P electronic component of Mean Well PA-120N-13P

Battery Chargers 99.36W 13.8V 7.2A V DETECTOR W/O PFC
Stock : 1

T198531 electronic component of Teledyne FLIR / Extech T198531

Battery Chargers External Battry CHGR E4,E5,E6,E8 Cameras
Stock : 0

CB1210A electronic component of Altech CB1210A

Battery Chargers BatryChrgr 12VDC 10A 115-230-277VAC in DR
Stock : 1

H-TRONIC AL 2000PLUS electronic component of H-TRONIC H-TRONIC AL 2000PLUS

Charger: for rechargeable batteries; Li-FePO4,acid-lead, gel; 2A
Stock : 0

GP X411 AA/AAA + 4X R6 2700MAH RECYKO electronic component of GP Batteries GP X411 AA/AAA + 4X R6 2700MAH RECYKO

Charger: for rechargeable batteries; Ni-MH; Size: AA, AAA
Stock : 1

H-TRONIC HTDC 5000 electronic component of H-TRONIC H-TRONIC HTDC 5000

Charger: for rechargeable batteries; acid-lead, gel; 5A; 80W
Stock : 1

VT04-CHARGER electronic component of Fluke VT04-CHARGER

Battery Chargers POWER SUPPLY,USB SOCKET PLUG & GO 5VDC 1 AMP 5 W - REPLACEMENT
Stock : 1

EPL100-12 electronic component of EVERPOWER EPL100-12

Charger: for rechargeable batteries; Li-Ion; 11.1V; 5A
Stock : 8

M C E E T R S T Y I F S I E T D N E T M O E 20 years of ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data New 190 Series II ScopeMeter 500 MHz Oscilloscopesthe first high- performance scopes built for harsh industrial environments Introducing the first high-performance portable oscilloscopes with 2 or 4 independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT III 1000 V/CAT IV 600 V safety rating. Choose from 500 MHz, 200 MHz, 100 MHz or 60MHz bandwidth models. Now plant maintenance engineers can take a 2- or 4-channel scope into the harsh world of industrial electronics. 190 Series IIa new generation of Fluke ScopeMeter Oscilloscopes The 190 Series II include these capabilities: Up to four independent floating isolated inputs, up to 1000 V Up to 5 GS/s real time sampling (Depending on model and channels used) Deep memory: 10,000 points per trace waveform capture (scope mode) CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments Up to seven hours of battery operation using BP291 Isolated USB host port for direct data storage to a USB memory device USB device port for easy PC communication Easy access battery door for quick battery swaps in the field Compact and only 2.2 kg (4.8 lb) Security slot: lock down oscilloscope with Kensington lock while unattended IP 51 rating, dust- and drip-proof Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals Frequency Spectrum using FFT-analysis Automatic capture and REPLAY of 100 screens ScopeRecord Roll mode gives 30,000 points per input channel for low frequency signal analysis TrendPlot paperless recorder mode with deep memory for long-term automatic measurements 5,000 count DMM included in the 2-channel models G M A E N E A T M I S Y T O I L 9 A 0 0 U 1 QOscilloscope modes 190-062 190-102 190-202 190-502 190-104 190-204 Vertical deflection Number of channels 2 2 2 2 4 4 Bandwidth 60 MHz 100 MHz 200 MHz 500 MHz 100 MHz 200 MHz Rise time 5.8 ns 3.5 ns 1.7 ns 0.7 ns 3.5 ns 1.7 ns Number of scope inputs 2 input channels plus external trigger 4 input channels Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination Input coupling AC or DC, with ground level indicator Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth Normal/invert/variable On each input channel, switched separately Input voltage CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details Vertical resolution 8 bit Accuracy (2.1 % of reading + 0.04 x range/div) 5 mV/div to 100 V/div Input impedance 1 M 1 % // 14 pF 2 pF Horizontal Maximum real-time sample 625 MS/s for 1.25 GS/s for 2.5 GS/s (2ch) 5 GS/s (single 1.25 GS/s for 2.5 GS/s (2ch) rate (sampled simultaneously) each channel each channel channel) or 2.5 each channel 1.25 GS/s (4ch) GS/s (on 2ch) Record length Up to 10,000 samples per channel Time base range 10 ns/div 5 ns/div 2 ns/div 1 ns/div. 5 ns/div 2 ns/div to 4 s/div to 4 s/div to 4 s/div to 4 s/div. to 4 s/div to 4 s/div Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord Roll mode (see Recorder mode) Maximum record length 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord Roll mode (see Recorder mode) Timing accuracy (0.01 % of reading + 1 pixel) Glitch capture 8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting) Display and acquisition Display 153 mm (6 in) full-color LCD with LED backlight Display modes Any combination of channels average on/off replay Visible screen width 12 divisions horizontally in scope mode Digital persistence modes off/short/medium/long/infinite and envelope mode Waveform mathematics One mathematical operation on any 2 input channels: add/subtract/multiply X-Y-mode Frequency Spectrum using FFT analysis Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord roll, glitch capture, waveform compare with automatic Pass/Fail testing Replay Trigger and delay Source Input A, B or External (via meter input) Input A, B, C or D Modes Automatic Connect-and-View, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle Connect-and-View Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred. Video triggering (on ch.A) NTSC, PAL, PAL+, SECAM Includes field 1, field 2 and line select High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz Pulse width triggering Pulse width qualified by time (on channel A) Allows for triggering <t, >t, =t, t, where t is selectable in minimum steps of 0.01 div or 50 ns Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay Dual slope triggering Triggers on both rising and falling edges alike N-cycle triggering Triggers on N-th occurrence of a trigger event N to be set in the range 2 to 99 2 Fluke Corporation ScopeMeter 190 Series II2 Fluke Corporation ScopeMeter 190 Series II

Tariff Desc

8504.40.90 BATTERY CHARGERS, cradle type
TC 9603454

8504.40.90 CHARGERS AND ADAPTERS, having ALL of:
a. input voltage NOT less than 90VAC and NOT greater than 264VAC
b. single phase frequency NOT less than 50 Hz and NOT greaterthan 60Hz
c. output voltage NOT less than 18V and NOT greater than 20V
d. output current NOT greater than 7A
TC 100523

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC TO DC OR DC TO DC OR DC TO AC, having ALL of:
a. input voltage NOT less than 10V and NOT greater than 252V
b. output voltage NOT less than 2V and NOT greater than 252V
c. wattage NOT less than 40W and NOT greater than 160W
d. output current NOT greater than 17A
TC 1021920

8504.40.90 CHARGERS, BATTERY, AC TO DC, having an output voltage NOT greater than 10V
TC 1434382

8504.40.90 BATTERY CHARGERS, including BOTH of:
a. lithium-ion AND/OR nickel-metal hydride (Ni-MH) batterycharging ports
b. mobile phone AND computer tablet charging USB port
TC 1436898

8504.40.90 1836821 CHARGE STATION, ELECTRIC MOTOR VEHICLE BATTERIES, output voltage NOT less than 150VDC and NOT greater than 920VDC being EITHER of:
a. car chargers having an operating temperature NOT less than -35C and NOT greater than 55C, including ALL of the following:
i) module power NOT less than 110 kW and NOT greater than 600kW;
ii) charge capability 400 V cars at 150kW;
iii) maximum DC output current per charge post NOT exceeding 500A;
iv) input voltage NOT greater than 450VAC;

b. heavy vehicle chargers having an operating temperatures NOT less than -35C and NOT greater than 50C with OR without automated 4-pole rooftop connection INCLUDING ALL of:
i) module power NOT less than 50kW and NOT greater than 600kW
ii) output current, per 150kW module, NOT greater than 250A
iii) input voltage NOT greater than 450VAC
FLUKE CALIBRATION
Fluke Electronics
FLUKE NETWORKS

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted