Rotary Switches Multi-Deck Rotary Switches SERIES 53, 57 and 59 1.125 Diameter, 1/4 Amp FEAtuRES Smallest Diameter Rotar y Switch with this Number of Positions and Current Capacity Militar y Qualified MIL-DTL-3786/36 Gold-plated Contact System Compatible with Logic Circuitr y DIMENSIONS in inches (and millimeters) Military Style Ser. 531.281 (32,54) + .046 (1,17) DIM. A Ser. 57 & 59 .437 .437 .020 (0,51) .020 .020 1.125 .010 (28,58 0,25) DIM. B REF. STUD (11,10 (11,10 PROJECTION 0,51) 0,51) .250 .020 (6,35 0,51) Rear views 1.000 (25.4) SER. 57 & 59 shown with circuit C 1.156 (29.36) SER. 53 L diagrams .010 (0,25) 45 .250 + .001 .002 DIA. C OF BUSHING (6,35 + 0,03 SEE L 0,05) C CIRCUIT KEYWAY .219 .004 MILITARY NUMBERS MARKED HERE L DIAGRAM (5.56 0,10) BUSHING KEYWAY C OF POSITION L .066 .002 (1,68 0,05) WIDE NO. 1 BY .036 .003 (0,91 0,08) DEEP FROM A .375 (9,53) DIA. INTEGRAL ASSEMBLY NUT. DO NOT REMOVE. 3/8-32 UNEF-2A THREAD Approx. Approx. Non-t urn Washer Detail D No. of Dimension Dimension Weight No. of Dimension Dimension Weight .375 .005 Decks A B Grams Decks A B Grams (9,53 0,13) 1 .916 (23,27) .032 (0,81) 50 7 3.164 (80,37) .281 (7,14) 110 2 1.249 (31,72) .032 (0,81) 60 8 3.497 (88,82) .281 (7,14) 120 3 1.582 (40,18) .032 (0,81) 70 9 3.830 (97,28) .281 (7,14) 130 .125 4 1.915 (48,64) .032 (0,81) 80 10 4.163 (105,74) .281 (7,14) 140 .003 5 2.248 (57,10) .032 (0,81) 90 11 4.496 (114,20) .281 (7,14) 150 (3,18 .032 .003 6 2.831 (71,91) .281 (7,14) 100 12 4.829 (122,66) .281 (7,14) 160 0,08) (0,81 0,08) STyLE M.187 (4,75) Mounting Hardware: Two mounting nuts, .094 (2,39) thick by .562 (14,27) across flats, one inter nal tooth lockwasher STyLE HS.125 (3,18) and one non-tur n washer (see detail D for dimensions), are supplied with switch010 (0,25) Grayhill par t number and date code mar ked on detent cover label. Customer par t number mar ked on request. Militar y par t number mar ked when required. 5 9 r o t a r y sw i t c h e s d o e s n o t ex t e n d t o a l l The line drawings shown above are applicable St ANDARD StyLE possible combinations listed in the Choices to the Style M and Style HS. The only difference MILIt ARy Qu ALIFIED and Limitations char t. The limitations on the between the two is the length of the tab of the The Ser ies 53, 57 and 59 rotar y switches are qualification are descr ibed in the char t shown non-tur n washer. The shor ter tab for the HS is all militar y type switches. Grayhill manufactures below. explained in the following paragraph. these switches in two styles: M and HS. Style M is unsealed and is not qualified Style HS is S t a n d a r d va r i a t i o n s , s u c h a s s h a f t a n d / o r The Ser ies 53, 57 and 59 Style HS rotar y switches shaft and panel sealed and is qualified. The bushing length, etc., that do not affect switch are qualified to MIL-DTL-3786/36. The Style HS non-qualified Style M can be regarded as our perfor mance can also be mar ked as qualified is shaft and panel sealed. The panel is sealed by Standard Style for types of switches. Although product. For complete details contact Grayhill. an O-r ing at the base of the bushing. The shaft it is not qualified, Style M is constr ucted of the Militar y qualified Ser ies 53, 57 and 59 Style HS is sealed by an O-r ing inside the bushing. These same militar y grade mater ials and will provide rotar y switches may be ordered by the M number seals do not alter the dimensions shown in the c o m p a r a b l e p e r fo r m a n c e i n a l l a r e a s . Fo r listed in MIL-DTL-3786/36 or by the Grayhill par t line drawings when the switch is mounted. example, the Style M switches, in addition to number. Militar y style switches will be mar ked the electr ical ratings listed elsewhere in these to the specification. A non-tur n washer, supplied with the mounting pages, will meet the following requirements of h a r d wa r e, m ay b e u s e d w i t h t h e S t y l e H S MIL-DTL-3786: switches. It is suggested that the non-tur n washer Style HS Switches are MIL-DtL-3786/36 Moisture Resistance: Medium and High Shock be mounted in the following manner to preser ve Qualified for the Following Characteristics Vibration (10 to 500 cps) Ther mal Shock (-65 the seal: from the front of the panel into a hole C to 125 C) Salt Spray Explosion Ter minal Max. No. Max. No. Max. No. that does not go through the panel. Series of Decks Poles/Deck t otal Poles/Switch Strength (pull, 2 lbs. minimum) and Stop Strength (15 pound-inches minimum). 53 5 8 24 T h e q u a l i fi c a t i o n o f t h e S e r i e s 5 3 , 5 7 a n d 57 5 4 20 59 5 5 20 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 www.grayhill.com3 4 5 4 6 5 7 6 8 7 Rotary Switches 9 8 10 9 11 10 12 11 13 14 12 15 Multi-Deck Rotary Switches CIRCuIt DIAGRAMS: Series 53 Switch is Viewed From Shaft End and Shown in Position No. 1 Rear View Note: All common ter minals are located above base ter minals as shown. 1.350 .015 C3 (34,29 0,38) C2 C2 15 15 1516 15 16 14 16 14 14 16 14 17 17 17 OVER TERMINALS 17 13 13 18 13 18 13 18 18 C4 12 12 19 12 12 19 19 19 11 11 11 20 11 20 20 20 C3 10 10 10 21 10 21 21 21 9 9 9 22 9 22 22 22 8 23 8 23 8 23 8 23 SEE 7 7 7 24 45 7 24 24 24 DETAIL C2 6 6 1 6 1 1 6 1 C1 5 5 5 2 5 2 2 2 4 3 C 4 3 4 3 4 3 C C C1 L L L C1 C1 1 C OF BUSHING 7 /2 L KEYWAY ONE POLE TWO POLE THREE POLE FOUR POLE C OF L POSITION 15 Angle C9 C10 NO. 1 C4 C5 C6 18 19 of throw C8 17 20 C11 C5 15 16 1516 14 17 SEE NOTE 14 17 16 21 13 18 13 18 15 22 C4 12 12 19 7.5 19 C7 11 C3 11 14 23 20 20 C7 C12 Note: Common location for a single pole per 10 10 21 21 13 24 deck switch. For common location on 9 22 9 22 12 1 multipole switches see circuit diagrams. 23 8 C 8 C6 C3 OF POSITION 1 23 C6 C1 L C8 11 2 7 7 24 24 6 10 3 6 1 1 5 2 5 2 4 3 9 4 4 3 C C 37.5 C2 L 8 5 C2 t erminal Detail L C5 7 6 C1 C2 C1 C4 C3 C OF BUSHING L KEYWAY .034 .003 FIVE OR SIX POLE SEVEN OR EIGHT POLE NINE THRU TWELVE POLE (0,86 0,08) .068 .005 (1,73 0,13) CIRCuIt DIAGRAMS: Series 59 Switch is Viewed From Shaft End and Shown in Position No. 1 Rear View Note: All common ter minals are located above base ter minals as shown. C3 12 13 12 12 13 13 11 14 11 14 11 14 C2 15 15 15 10 10 10 1.190 .015 16 16 16 9 9 9 (30,23 0,38) 17 17 17 8 8 8 OVER TERMINALS C2 18 18 18 7 7 7 C4 19 19 19 6 6 6 45 20 5 20 20 5 5 1 C1 4 4 1 4 1 2 C1 3 3 2 2 3 C 18 C C OF BUSHING L L SEE L C1 18 Angle KEyWAy DETAIL ONE POLE TWO POLE THREE OR FOUR POLE of throw C OF POSITION L NO. 1 C7 C4 C6 12 12 13 13 14 11 14 C8 11 15 10 10 15 C3 C5 16 16 9 9 C5 C9 SEE NOTE 8 8 17 17 18 C4 18 7 7 19 6 6 19 Note: Common location for a single pole per C10 5 20 5 20 deck switch. For common location on C2 1 C3 4 1 4 2 3 2 3 multipole switches see circuit diagrams. C C1 C C1 L C2 L FIVE POLE SIX THRU TEN POLE Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 www.grayhill.com 16 13 17 14 18 15 19 16 20 21 17 22 18 23 19 24 20 1 1 2 3 2 GRAyHILL LA GRANGE ILLINOI S GRAyHILL LA GRANGE ILLINOI S