12 ~ 18W AC-DC Single Output Interchangeable Wall-mounted type GE18 series Features : Interchangeable AC plugs (plug kit sold seperately) Universal AC input / Full range No load power consumption< 0.3W/230VAC for 5~24V(<0.5W/230VAC for 48V) Meet energy star(CEC) level V for 5~24V(level for 48V) Meet EISA 2007 (Energy Independence and Security Act) Class power (without earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Pass LPS Approvals: UL / CUL / TUV / CB / FCC / CE / C-Tick 2 years warranty TUV geprUfre Rheinland Product Safety Sicherheit AC INLET PLUG TYPE Australian type U.K type European type US type Mix four type ORDER NO. AC plug-AU AC plug-UK AC plug-EU AC plug-US AC plug-MIX SPECIFICATION POWER SUPPLY MAIN BODY ORDER NO. GE18 0I 5-P1J GE18 0I 7-P1J GE18 0I 9-P1J GE18 1I 2-P1J GE18 1I 5-P1J GE18 1I 8-P1J GE18 2I 4-P1J GE18 4I 8-P1J SAFETY MODEL NO. FRA018-S05- I FRA018-S07- I FRA018-S09- I FRA018-S12- I FRA018-S15- I FRA018-S18- I FRA018-S24- I FRA018-S48- I DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V RATED CURRENT 2.4A 1.73A 2.0A 1.5A 1.2A 1.0A 0.75A 0.375A CURRENT RANGE 0 ~ 2.4A 0 ~ 1.73A 0 ~ 2.0A 0 ~ 1.5A 0 ~ 1.2A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.375A RATED POWER (max.) 12W 13W 18W 18W 18W 18W 18W 18W OUTPUT RIPPLE & NOISE (max.) Note.3 50mVp-p 75mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p 300mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 3.0% 3.0% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION Note.6 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 3.0% 3.0% SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 72% 75% 75% 78% 80% 80% 81% 81% INPUT AC CURRENT 0.7A / 100VAC 0.4A / 230VAC INRUSH CURRENT (max.) COLD START 40A / 100VAC 80A / 230VAC LEAKAGE CURRENT (max.) 0.25mA / 240VAC 110% ~ 200% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 115% ~ 135% OVER VOLTAGE Protection type : Clamp by zener diode -10 ~ +50 (Refer to output load derating curve) WORKING TEMP. WORKING HUMIDITY 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03% / (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, CSA C22.2, TUV EN60950 -1 approved WITHSTAND VOLTAGE I/P-O/P:4242VDC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B HARMONIC CURRENT Compliance to EN61000-3-2,3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A LIFE 2 years : 100% load 30 , 8 hours / day MTBF 100Khrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 81*43*40.5mm (L*W*H) PACKING 134g 60pcs / 12.32kg / CARTON PLUG Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock Other type available by customer requested DC OUTPUT CONNECTOR See page2 CABLE 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. NOTE 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12 twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load 7.Main body unit and AC inlet plug should be ordered seperately it needs to be used along with any of the AC inlet plug. File Name:GE18-SPEC 2009-03-26 MeanWell Direct Tel: +44 (0)118 970 3858 E-mail: sales meanwelldirect.co.uk I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I12 ~ 18W AC-DC Single Output Interchangeable Wall-mounted type GE18 series Mechanical Specification Unit:mm AWM2468 18AWG*2C 1500 50mm ID 2.1 x OD 5.5 11 0.5mm 81 Plug Assignment Standard plug: P1J (option) P1J P/N OUTPUT CENTER + Derating Curve Static Characteristics 100 90 100 80 75 70 50 60 50 40 -10 10 20 30 40 50 90 95 100 115 120 140 160 180 200 220 240 264 Ta ( ) File Name:GE18-SPEC 2009-03-26 MeanWell Direct Tel: +44 (0)118 970 3858 E-mail: sales meanwelldirect.co.uk LOAD (%) 40.5 43 36.5 LOAD (%)