Solid State Relays G3PA Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting possible for linking terminals. (Except for G3PA-260B-VD and G3PA-450B-VD-2.) Applicable with 3-phase loads. Replaceable power element cartridges. Complies with VDE 0160 (finger protection), with a dielec- tric strength of 4,000 V between input and load. Complies with VDE 0805, IEC 950. Certified by UL, CSA, and VDE (reinforced insulation). Ordering Information List of Models To Order: Select the part number and add the rated input voltage range. (e.g., G3PA-430B-VD-2 DC12-24) Isolation Zero cross function Indicator Rated output load Rated input voltage Model Phototriac Yes Yes 10 A at 24 to 240 VAC 5 to 24 VDC G3PA-210B-VD coupler 20 A at 24 to 240 VAC G3PA-220B-VD 40 A at 24 to 240 VAC G3PA-240B-VD 60 A at 24 to 240 VAC G3PA-260B-VD No 10 A at 24 to 240 VAC G3PA-210BL-VD 20 A at 24 to 240 VAC G3PA-220BL-VD 40 A at 24 to 240 VAC G3PA-240BL-VD 60 A at 24 to 240 VAC G3PA-260BL-VD Yes 10 A at 24 to 240 VAC 24 VAC G3PA-210B-VD 20 A at 24 to 240 VAC G3PA-220B-VD 40 A at 24 to 240 VAC G3PA-240B-VD 60 A at 24 to 240 VAC G3PA-260B-VD 20 A at 180 to 400 VAC 12 to 24 VDC G3PA-420B-VD 30 A at 180 to 400 VAC G3PA-430B-VD 20 A at 200 to 480 VAC G3PA-420B-VD-2 30 A at 200 to 480 VAC G3PA-430B-VD-2 50 A at 200 to 480 VAC G3PA-450B-VD-2 Solid State Relays G3PA 437Replacement Parts Name Carry current Load voltage range Applicable SSR Model VDE certification Power Device 10 A 19 to 264 VAC G3PA-210B-VD DC5-24 G32A-A10-VD DC5-24 Yes Cartridge G3PA-210BL-VD DC5-24 G32A-A10L-VD DC5-24 G3PA-210B-VD AC24 G32A-A10-VD AC24 20 A G3PA-220B-VD DC5-24 G32A-A20-VD DC5-24 G3PA-220BL-VD DC5-24 G32A-A20L-VD DC5-24 G3PA-220B-VD AC24 G32A-A20-VD AC24 40 A G3PA-240B-VD DC5-24 G32A-A40-VD DC5-24 G3PA-240BL-VD DC5-24 G32A-A40L-VD DC5-24 G3PA-240B-VD AC24 G32A-A40-VD AC24 60 A G3PA-260B-VD DC5-24 G32A-A60-VD DC5-24 G3PA-260BL-VD DC5-24 G32A-A60L-VD DC5-24 G3PA-260B-VD AC24 G32A-A60-VD AC24 20 A 150 to 440 VAC G3PA-420B-VD DC12-24 G32A-A420-VD DC12-24 30 A G3PA-430B-VD DC12-24 G32A-A430-VD DC12-24 20 A 180 to 528 VAC G3PA-420B-VD-2 DC12-24 G32A-A420-VD-2 DC12-24 30 A G3PA-430B-VD-2 DC12-24 G32A-A430-VD-2 DC12-24 50 A G3PA-450B-VD-2 DC12-24 G32A-A450-VD-2 DC12-24 Specifications Ratings (at an Ambient Temperature of 25C) Input Model Rated voltage Operating Voltage Input current Voltage level range impedance Must operate voltage Must release voltage G3PA-2B-VD 5 to 24 VDC 4 to 30 VDC 7 mA max. 4 VDC max. 1 VDC min. G3PA-2BL-VD 20 mA max. G3PA-2B-VD 24 VAC 19.2 to 26.4 VAC 1.4 k 20% 19.2 VAC max. 4.8 VAC min. G3PA-4B-VD(-2) 12 to 24 VDC 9.6 to 30 VDC 7 mA max. 9.2 VDC max. 1 VDC min. Output Model Applicable load Rated load voltage Load voltage range Load current Inrush current G3PA-210B(L)-VD 24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.1 to 10 A 150 A (60 Hz, 1 cycle) G3PA-220B(L)-VD 0.1 to 20 A 220 A (60 Hz, 1 cycle) G3PA-240B(L)-VD 0.5 to 40 A 440 A (60 Hz, 1 cycle) G3PA-260B(L)-VD 0.5 to 60 A 440 A (60 Hz, 1 cycle) G3PA-420B-VD 180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0.5 to 20 A 220 A (60 Hz, 1 cycle) G3PA-430B-VD 0.5 to 30 A 440 A (60 Hz, 1 cycle) G3PA-420B-VD-2 200 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to 20 A 220 A (60 Hz, 1 cycle) G3PA-430B-VD-2 0.5 to 30 A 440 A (60 Hz, 1 cycle) G3PA-450B-VD-2 0.5 to 50 A 440 A (60 Hz, 1 cycle) Refer to Engineering Data for further details. 438 Solid State Relays G3PA