G3TB I/O Solid State Relay I/O SSR Used as Interface between Logic Circuitry and Load A variety of AC/DC input and output modules are classified by color. Operation can be monitored easily by LED indicator. Dielectric strength of 4,000 V between input and output terminals. Refer toSolid State Relays Common Precaution. Lineup includes models with UL and CSA certification (model numbers ending in -US). RoHS Compliant List of Models Input Modules Logic level Logic level Minimun Isolation Indicator Rated input voltage Model Supply voltage Supply current packing unit 100 to 240 VAC G3TB-IAZR02P Photocoupler Yes 4 to 32 VDC 25 mA 20 pcs 5 to 24 VDC G3TB-IDZR02P Output Modules Minimun Isolation Zero cross function Indicator Rated output voltage Rated input voltage Model packing unit G 3 Yes 5 to 24 VDC G3TB-OA203PZ Yes T No 4 to 24 VDC G3TB-OA203PZM 3 A at 100 to 240 VAC B Yes 5 to 24 VDC G3TB-OA203PL No No 4 to 24 VDC G3TB-OA203PLM Photocoupler 20 pcs Yes 5 to 24 VDC G3TB-ODX03P 3 A at 5 to 48 VDC No 4 to 24 VDC G3TB-ODX03PM Yes 5 to 24 VDC G3TB-OD201P 1.5 A at 48 to 200 VDC No 4 to 24 VDC G3TB-OD201PM Ratings Input Module Input Output Item Voltage level Item Output Operating Input Logic level Output breakdown Rated voltage Must operate Must release voltage current supply voltage current Model voltage Model voltage voltage G3TB-IAZR02P 100 to 240 VAC 80 to 264 VAC 5 mA max. 80 VAC max. 10 VAC min. G3TB-IAZR02P 4 to 32 VDC 32 VDC 25 mA G3TB-IDZR02P 5 to 24 VDC 4 to 32 VDC 5 mA max. 4 VDC max. 1 VDC min. max. max. G3TB-IDZR02P 4 to 32 VDC Output Module Input Item Voltage level Rated Operating Input current Must operate Must release Model voltage voltage voltage voltage G3TB-OA203PZ 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-OA203PZM 4 to 24 VDC 3 to 32 VDC 3 VDC max. G3TB-OA203PL 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-OA203PLM 4 to 24 VDC 3 to 32 VDC 3 VDC max. 5 mA max. 1 VDC min. G3TB-ODX03P 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-ODX03PM 4 to 24 VDC 3 to 32 VDC 3 VDC max. G3TB-OD201P 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-OD201PM 4 to 24 VDC 3 to 32 VDC 3 VDC max. Output Item Applicable load Model Rated load voltage Load voltage range Load current Inrush current G3TB-OA203PZ G3TB-OA203PZM 45 A 100 to 240 VAC 75 to 264 VAC 0.05 to 3 A *1, 2 (60 Hz, 1 cycle) G3TB-OA203PL *1. The minimum current value is measured at G3TB-OA203PLM 10C min. G3TB-ODX03P *2. The applicable output load current varies 5 to 48 VDC 4 to 60 VDC 0.01 to 3 A *1, 2 18 A (10 ms) G3TB-ODX03PM depending on the ambient temperature.Refer to G3TB-OD201P reference data theLoad Current vs. Ambient 48 to 200 VDC 40 to 200 VDC 0.01 to 1.5 A *1, 2 9 A (10 ms) G3TB-OD201PM Temperatur rating characteristic for details. 1G3TB I/O Solid State Relay Characteristics Input Module Output Module Model Model G3TB- G3TB- G3TB- G3TB- G3TB - G3TB- G3TB - G3TB- G3TB-IAZR02P G3TB-IDZR02P Item Item OA203PZ OA203PZM OA203PL OA203PLM ODX03P ODX03PM OD201P OD201PM Operate time 20 ms max. 1 ms max. 1/2 of load power source Operate time 1 ms max. 0.5 ms max. cycle + 1 ms max. Release time 20 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. 2 ms max. Output ON 0.4 V max. voltage drop Output ON 1.6 V (RMS) max. 1.6 V max. 2.5 V max. voltage drop Leakage current 100 A max. Leakage current 5 mA max. (at 200 VAC) 1 mA max. Insulation 100 M min. (at 500 VDC) resistance Insulation 100 M min. (at 500 VDC) resistance Dielectric 4,000 VAC, 50/60 Hz for 1 min between strength input and output Dielectric 4,000 VAC, 50/60 Hz for 1 min between input and output strength 10 to 55 to 10 Hz, Vibration 0.75-mm single amplitude Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5mm double amplitude) (1.5mm double amplitude) resistance 2 2 Shock resistance 1,000 m/s Shock resistance 1,000 m/s Storage 30C to 100C Storage 30C to 100C (with no icing or condensation) temperature (with no icing or condensation) temperature Ambient Ambient 30C to 80C (with no icing or condensation) 30C to 80C operating operating Minimum load current: 10 to 80C (with no icing or condensation) temperature temperature Refer to the Load Current - Ambient Temperature Rating for the minimum load current. Ambient Ambient operating 45% to 85%RH operating 45% to 85%RH humidity humidity Weight Approx. 22 g Weight Approx. 32 g Engineering Data Load Current vs. Ambient Te mperature Characteristics G3TB-OA203PZ G3TB-OA203PLM G3TB-OA203PZM G3TB-ODX03P G3TB-OD201P G 3 G3TB-OA203PL G3TB-ODX03PM G3TB-OD201PM T 5 5 B 2 4 4 1.5 3 3 1 2 2 0.5 1 1 Minimum load current Minimum load current Minimum load current 0.1 0.1 0.1 0.01 0.05 0.01 0 0 0 -30 -20 0 20 40 60 80 100 -30 -20 0 20 40 60 80 100 10 -30 -20 0 20 40 60 80 100 10 10 Ambient temperature (C) Ambient temperature (C) Ambient temperature (C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3TB-OA203PZ G3TB-OA203PL G3TB-ODX03P G3TB-OD201P G3TB-OA203PZM G3TB-OA203PLM G3TB-ODX03PM G3TB-OD201PM 50 30 15 28 14 26 13 24 12 40 22 11 20 10 30 18 9 16 8 14 7 12 6 20 10 5 8 4 6 3 10 4 2 2 1 0 0 0 10 30 50 100 200 500 1,000 5,000 10 30 50 100 300 500 1,000 3,000 10 30 50 100 300 500 1,000 3,000 Energized time (ms) Energized time (ms) Energized time (ms) 2 Inrush current (A. Peak) Load current (A) Load current (A) Inrush current (A. Peak) Inrush current (A. Peak) Load current (A)