Linear Sensor Indicator K3HB-S CSM K3HB-S DS E 11 4 Linear Sensor Indicator for High-speed, High- precision Measurement and Discrimination Easy recognition of judgement results using color display that can be switched between red and green. * Equipped with a position meter that represents measured amounts and relative positions. Develop a variety of measurement and discrimination applications using external event inputs. Series expanded to include DeviceNet models. Short body with depth of only 95 mm (from behind the front panel), or 97 mm for DeviceNet models. UL certification approval (Certification Mark License). CE Marking conformance by third party assessment body. Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66). *Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet. You can change the display color by setting it, but you cannot switch it based on the judgement results. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-S K3HB-S - 12 34 5 1 5 2. Sensor Power Supply/Output Type Code 1. Input Sensor Code None: None SD: DC Process input CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC +/10%, 80 mA) (See note 1.) 5. Supply Voltage L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply 100-240 VAC: 100 to 240 VAC (12 VDC +/10%, 80 mA) (See note 2.) L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power 24 VAC/VDC: 24 VAC/VDC supply (12 VDC +/10%, 80 mA) (See note 2.) A: Sensor power supply (12 VDC +/10%, 80 mA) FLK1A: Communications (RS-232C) + Sensor power supply (12 VDC +/10%, 80 mA) (See note 2.) FLK3A: Communications (RS-485) + Sensor power supply (12 VDC +/10%, 80 mA) (See note 2.) Note: 1. CPA can be combined with relay outputs only. 2. Only one of the following can be used by each Digital Indicator: RS- 232C/RS-485 communications, a linear output, or DeviceNet communications. Optional Board 3. Relay/Transistor Output Type Code Sensor Power Supply/Output Boards None: None C1: Relay contact (H/L: SPDT each) K33- C2: Relay contact (HH/H/LL/L: SPST-NO each) 2 T1: Transistor (NPN open collector: HH/H/PASS/L/LL) T2: Transistor (PNP open collector: HH/H/PASS/L/LL) Relay/Transistor Output Boards BCD : BCD output + transistor output (NPN open collector: HH/H/PASS/L/ LL) K34- DRT: DeviceNet (See note 2.) 3 A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code Event Input Boards None: None 1: 5 inputs (M3 terminal blocks), NPN open collector K35- 2 : 8 inputs (10-pin MIL connector), NPN open collector 4 3: 5 inputs (M3 terminal blocks), PNP open collector 4 : 8 inputs (10-pin MIL connector), PNP open collector There is no bank selection forNon andDeviceNe types ofTransistor Output Type Cod. Note: The following combinations are not possible. Communications (FLK A) + DeviceNet (DRT) Communications (FLK A) + BCD output (BCD) Linear current/voltage (L A) + DeviceNet (DRT) 1K3HB-S Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model Y92A-49N K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC Power consumption 100 to 240 V: 18 VA max. (max. load) (See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input DC voltage/current A/D conversion method Sequential comparison system External power supply 12 VDC 10%, 80 mA (models with external power supply only) Event inputs Timing input NPN open collector or no-voltage contact signal (See note 2.) ON residual voltage: 3 V max. ON current at 0 : 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max. Startup compensa- NPN open collector or no-voltage contact signal tion timer input ON residual voltage: 2 V max. ON current at 0 : 4 mA max. Hold input Max. applied voltage: 30 VDC max. Reset input OFF leakage current: 0.1 mA max. Forced-zero input Bank input Output ratings (de- Relay output 250 VAC, 30 VDC, 5 A (resistive load) pends on the model) Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V no output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green) Main functions Scaling function, 2-input calculation function, measurement operation selection, averaging, previous average value comparison, forced-zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Ambient operating temperature 10 to 55 C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature 25 to 65 C (with no icing or condensation) Altitude 2,000 m max. Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De- viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend- ed. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 2