DATA SHEET Standard AC Output Modules Form 449-120920 Standard AC Output Modules Features Rugged construction 4000 volts of optical isolation between the field devices and the control logic (transient) Zero voltage turn-on and zero current turn-off OAC5 Module Description AC output modules are used for controlling or switching AC loads. Each module providesup to 4000 volts (transient) of optical isolation between the field devices and the control logic. With the exception of the OAC5A5 module, all AC output modules are equivalent to a single pole, single throw, normally open contact (FORM A, SPST-NO, Make). The OAC5A5 is equivalent to a single pole, single throw, normally closed contact (FORM B, SPST-NC, Break). All AC output modules feature zero voltage turn-on and zero current turn-off. Typical uses and applications for AC output modules include switching the following loads: Part Numbers Relays Part Description Solenoids OAC5 AC Output 12140 VAC, 5 VDC Logic Motor starters Heaters OAC5A AC Output 24280 VAC, 5 VDC Logic Lamps or indicators AC Output 24280 VAC, 5 VDC Logic, higher OAC5H* current rating OAC5A5 AC Output 24280 VAC, 5 VDC Logic, NC OAC15 AC Output 12140 VAC, 15 VDC Logic OAC15A AC Output 24280 VAC, 15 VDC Logic OAC24 AC Output 12140 VAC, 24 VDC Logic OAC24A AC Output 24280 VAC, 24 VDC Logic AC Output 24280 VAC, 24 VDC Logic, higher OAC24H* current rating * Not UL approved Opto 22 43044 Business Park Drive Temecula, CA 92590-3614 www.opto22.com PAGE SALES 800-321-6786 951-695-3000 FAX 951-695-3095 sales opto22.com SUPPORT 800-835-6786 951-695-3080 FAX 951-695-3017 support opto22.com 1 20062012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.Standard AC Output Modules Specifications General One Cycle Surge 80 amps peak Peak Repetitive Voltage 500 Volts Operating Ambient Temperature -30 to 70 C Isolation, Input-to-Output (Transient) 4,000 Vrms Minimum Load Current 20 milliamps Operating Frequency 2565 Hz Turn-on Time 1/2 cycle maximum-zero voltage Turn-off Time 1/2 cycle maximum-zero current DV/DT - Off-State 200 volts/microseconds DV/DT - Commutating Snubbed for rated 0.5 power factor load Output Voltage Drop Maximum Peak 1.6 volts Off-State Leakage 5 milliamps rms Nominal Voltage - 60 Hz 2.5 milliamps rms for OAC5A OAC15A, and OAC24A 120 VAC Module Specifications OAC5A5 3 3 3 3 3 Units OAC5 OAC5A OAC5H OAC15 OAC15A OAC24 OAC24A OAC24H (NC) Line Voltage - Nominal VAC 120 240 240 120/240 120 240 120 240 240 Operating Voltage Range VAC 12140 24280 24280 24280 12140 24280 12140 24280 24280 Current Rating 45 C Ambient amps 3 3 4 3 3 3 3 3 4 70 C Ambient amps 2 2 2 2 2 2 2 2 2 1 UL Motor Load Rating amps 1.5 1.5 -- * 1.5 1.5 1.5 1.5 1.5 -- Logic Voltage - Nominal VDC 5 5 5 5 15 15 24 24 24 2 VDC 2.582.582.582.58916 916 1832 1832 1832 Logic Voltage Range (Vcc) 1 VDC 2.5 2.5 2.5 2.5 9 9 18 18 18 Logic Pickup Voltage Logic Dropout Voltage VDC 1 1 1 1 1 1 1 1 1 Logic Input Current- Normal Logic mA 12 12 12 12 15 15 18 18 18 Voltage (I in schematic dia- out gram) Control Resistance Ohms 220 220 220 220 1K 1K 2.2K 2.2K 2.2K (R in schematic diagram) c 1 Not UL approved 2 Module only 3 Not for use with Opto 22 brains Opto 22 43044 Business Park Drive Temecula, CA 92590-3614 www.opto22.com PAGE SALES 800-321-6786 951-695-3000 FAX 951-695-3095 sales opto22.com SUPPORT 800-835-6786 951-695-3080 FAX 951-695-3017 support opto22.com 2 20062012 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. DATA SHEET Standard AC Output Modules Form 449-120920