LS (ALS) VDE 1a/1c 10A small cubic type LS RELAYS (ALS) power relays FEATURES TYPICAL APPLICATIONS 1. Universal terminal footprint 1. Household appliances Same terminal pitch as our JS relay Refrigerator, Heater, Washing machine, Dishwasher, Rice cooker, etc. 2. Ofce automation equipment, Home 12.0 appliances, etc472 3. Game machines, etc. 2.0 12.2 .079 .480 2. Space-saving and Compact cube type 19.5 (L) 15.5 (W) 15.2 (H) mm .768 (L) .610 (W) .598 (H) inch Comparison with our JS relay: PCB mount area: 86% 3. Excellent heat resistance and tracking performance 85C 185F ambient operating temperature (UL Class B) Compatibility available for UL Class F Uses PTI250 material EN60335-1 GWT compliant (Tested by VDE) 4. Supports all safety standards Compliance with RoHS Directive UL/C-UL and VDE certied ORDERING INFORMATION ALS T W LS relay Contact arrangement and Protective construction 1: 1 Form C, Flux-resistant type 2: 1 Form C, Sealed type 3: 1 Form A, Flux-resistant type 4: 1 Form A, Sealed type Coil insulation class B: Class B insulation F: Class F insulation Nominal coil voltage (DC) 05: 5 V, 06: 6 V, 09: 9 V, 12: 12 V, 18: 18 V, 24: 24 V, 48: 48 V Flame resistance and tracking resistance T: EN60335-1 (Conform) Packing style W: Carton packing Note: Certified by UL/C-UL and VDE All Rights Reserved COPYRIGHT Panasonic Electric Works Co., Ltd.LS (ALS) TYPES Part No. Contact arrangement Nominal coil voltage Sealed type Flux-resistant type 5V DC ALS405TW ALS305TW 6V DC ALS406TW ALS306TW 9V DC ALS409TW ALS309TW 1 Form A 12V DC ALS412TW ALS312TW 18V DC ALS418TW ALS318TW 24V DC ALS424TW ALS324TW 48V DC ALS448TW ALS348TW 5V DC ALS205TW ALS105TW 6V DC ALS206TW ALS106TW 9V DC ALS209TW ALS109TW 1 Form C 12V DC ALS212TW ALS112TW 18V DC ALS218TW ALS118TW 24V DC ALS224TW ALS124TW 48V DC ALS248TW ALS148TW Standard packing: Carton: 100 pcs. Case: 500 pcs. Notes: 1. : Input the following letter. Class B insulation: B, Class F insulation: F 2. Carton packing symbol W is not marked on the relay. 3. Please consult with our sales ofce on a tube packing type. RATING 1. Coil data Nominal operating Nominal operating Nominal coil Pick-up voltage Drop-out voltage Coil resistance Max. applied voltage current power voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) (at 20C 68F) 5V DC 72 mA 69.4 6V DC 60 mA 100 9V DC 40 mA 225 75%V or less of 10%V or more of 130%V of 12V DC nominal voltage nominal voltage 30 mA 400 360mW nominal voltage* (Initial) (Initial) 18V DC 20 mA 900 24V DC 15 mA 1,600 48V DC 7.5mA 6,400 * Pick-up and drop-out voltages increase approximately 0.4% for each 1C 33.8F where the standard temperature is 20C 68F. Therefore, when using the relay where the ambient temperature is high, please take into consideration the rise in pick-up voltage due to ambient temperature and determine a coil nominal voltage that is within the maximum applied voltage range. 2. Specications Characteristics Item Specications Contact material AgNi/AgSnO2 type Contact Arrangement 1 Form A, 1 Form C Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A) Nominal switching capacity (resistive load) 10A 277V AC (N.O.), 6A 277V AC (N.C.) Max. switching power (resistive load) 2,770VA (N.O.), 1,662VA (N.C.) Rating Max. switching voltage 277V AC Max. switching current 10A AC (N.O.), 6A AC (N.C.) 1 Min. switching capacity (reference value)* 100mA, 5V DC Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA) Breakdown voltage (Initial) Between contact and coil 1,500 Vrms for 1 min. (Detection current: 10 mA) Electrical Max. 45C 113F (By resistive method, nominal coil voltage applied to the coil Temperature rise (coil) characteristics contact carrying current: 10A, at 85C 185F) Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms (nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 10 ms (nominal coil voltage applied to the coil, excluding contact bounce time) Release time (at nominal voltage) (at 20C 68F) (Without diode) 2 Functional 98 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive 980 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2 mm 7 Mechanical (at 180 times/min.) Min. 10 Expected life Electrical (at 20 times/min.) (at 20C 68F) 4 5 4 10A 250V AC: 510 (N.O.), 6A 250V AC: 10 (N.O.), 6A 250V AC: 510 (N.C.) (resistive load) 3 Ambient temperature* : 40C to +85C 40F to +185F (class B insulation) 2 Conditions for operation, transport and storage* 40C to +105C 40F to +253F (class F insulation) Conditions Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Max. operating speed 20 times/min. (at nominal switching capacity) Unit weight Approx. 10 g .35 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *3. The pick-up and drop out voltages rise approximately 0.4% for every 1C 33.8F given a standard ambient temperature of 20C 68F. Therefore, when using relays where the ambient temperature is high, please take into consideration the rise in pick-up and drop out voltages and keep the coil applied voltage within the maximum applied voltage. All Rights Reserved COPYRIGHT Panasonic Electric Works Co., Ltd.