DIN Rail Mount Datasheet DRC Series 7.6 Amp AC Semiconductor Motor Controller Load voltage range up to 600 VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output C-UL-US Listed, IEC Rated, CE & RoHS Compliant, Horsepower Rated Built-in Overvoltage Protection Ultra-efficient thermal management design (Patented) Start / Stop Reversing Solicon DRC3 Series are Solid State Contactors intended for instantaneous change of direction is commanded, then it will frequently switching on and off three phase loads up to 5 HP, 600 delay the direction change by 100msec in order to prevent VAC 7.6 Amps. They are available in both contactor versions simultaneous forward and reverse operations. DRC3P and reversing contactor versions DRC3R. All the models of Solicon DRC3 Series combine the benefits and The Solicon Contactor DRC3P is available in either instantaneous advantages of a solid state contactor with the functionality and turn-on (for Motor Control) or zero voltage turn-on (for Resistive simplicity of use of an electromechanical contactor thanks to the Loads). It is available in either 2 or 3 controlled leg versions. The proprietary thermal management technology (Patented) and 2 legs control version is particularly suitable for motor control complete electrical insulation (no grounding required) the circuits where the neutral conductor is not utilized. embedded auxiliary contacts, normally open and/or normally closed, are intended to be used at 18-280VAC. Five different The Solicon Reversing Contactor DRC3R includes an interlock control voltages are available in order to cover most applications. control that allows only off, forward and reverse operation in a All models include overvoltage protection. safe mode while providing high space saving it switches instantaneously upon application of the control voltage unless an PRODUCT SELECTION Control Voltage Without Auxiliary Contact 1 NO+NC Auxiliary Conctat 2 NO Auxiliary Contact 230 VAC DRC3P48A400, DRC3R48A400 DRC3P48A411 DRC3P48A420, DRC3R48A420 120 VAC DRC3P48B400, DRC3R48B400 DRC3P48B411 DRC3P48B420, DRC3R48B420 48 VAC/DC DRC3P48C400, DRC3R48C400 DRC3P48C411 DRC3P48C420, DRC3R48C420 24 VAC/DC, 24 VAC DRC3P48D400, DRC3R48D400 DRC3P48D411 DRC3P48D420, DRC3R48D420 24 VDC DRC3R48E400 DRC3R48E420 AVAILABLE OPTIONS Operating Voltage Load Current per Phase 40: 400 VAC 4: 7.6 Amp FLA (3R function only) (x2 Controlled Legs Switching Mode 48: 480 VAC & 3R function) (3P function only) 60: 600 VAC 4.8 Amp FLA Blank: Zero Voltage Turn-On (3P function only) Series (x3 Controlled Legs only) R: Instantaneous Turn-On DRC 3P 48 D 4 00 R 2 Function Control Voltage Auxiliary Contacts, Controlled Legs 3P: Contactor A: 208-265 VAC N.O. - N.C. (3P function only) 3R: Reversing Contactor B: 90-140 VAC 00: Not included Blank: 3 Controlled Legs C: 36-55 VAC/DC 11: 1 Solid State Auxiliary 2: 2 Controlled Legs D: 18-30 VAC/DC Contact, Normally Open (3P function only) 1 Solid State Auxiliary 18-30 VAC Contact, Normally Closed (3R function only) (3P function only) Required for valid part number E: 18-30 VDC 20: 2 Solid State Auxiliary (3R function only) Contacts, Normally Open For options only and not required for valid part number FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2018 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount Datasheet (1) OUTPUT SPECIFICATIONS Description DRC3P48x4x DRC3P48x4x2 DRC3P60x4x DRC3P60x4x2 DRC3R40x4x DRC3R48x4x Operating Voltage (47-63Hz) Vrms 48-530 48-530 48-600 48-600 48-415 48-510 Transient Overvoltage Vpk (2)(3) 1200 1200 1200 1600 1200 1200 Maximum Off-State Leakage Current Rated Voltage mArms 3.0 3.0 1.0 1.0 5.5 5.5 Maximum Off-State dv/dt Maximum Rated Voltage V/sec 500 500 500 500 500 500 Load Current, General Use UL508 /AC51 40C Arms (4) 5 7.6 5 7.6 7.6 7.6 Load Current, Motor Controller UL508 /AC-53a 480VAC Arms (4) 4.8 7.6 4.8 7.6 7.6 7.6 Minimum Load Current Arms 0.15 0.15 0.15 0.15 0.15 0.15 Maximum Surge Current Apk 1 Cycle 60Hz 750 750 750 750 750 625 Maximum Surge Current Apk 1 Cycle 50Hz 716 716 716 716 716 597 2 2 Maximum I t for Fusing (8.33msec) A sec 2330 2330 2330 2330 2330 1621 2 2 Maximum I t for Fusing (10msec) A sec 2560 2560 2560 2560 2560 1779 Maximum On-State Voltage Drop Rated Current Vpk 1.35 per channel 1.35 per channel 1.35 per channel 1.35 per channel 1.5 per channel 1.5 per channel Minimum Power Factor (with Maximum Load) 0.5 0.5 0.7 0.7 0.5 0.5 Ratings according to UL 508/IEC60947-4-2 HP/kW : 240 VAC 1/.75 2/1.5 1/.75 2/1.5 2/1.5 2/1.5 Ratings according to UL 508/IEC60947-4-2 HP/kW : 400 VAC 2/1.5 3/2.2 2/1.5 3/2.2 3/2.2 3/2.2 Ratings according to UL 508/IEC60947-4-2 HP/kW : 480 VAC 3/2.2 5/3.7 3/2.2 5/3.7 - 5/3.7 Motor Ratings 600 VAC HP/kW - - 3/2.2 5/3.7 - - (1) INPUT SPECIFICATIONS Description Option A Option B Option C Option D Option E Control Voltage Range (5) 208-265 VAC 90-140 VAC 36-55 VAC / VDC 18-30 VAC / VDC 18-30 VDC Minimum Turn-On Voltage (6) 208 VAC 90 VAC 36 VAC / VDC 18 VAC / VDC 18 VDC Must Turn-Off Voltage 40 VAC 10 VAC 4 VAC / VDC 4 VAC / VDC 4 VDC Minimum Input Current (for on-state) mA 6.1 7.5 12 12.5 12.5 Maximum Input Current mA 8 13 20 32 32 Nominal Input Impedance Ohms 33k 12.5k 3k 0.93k 0.93k Maximum Delay to Turn-On msec (7) 30 30 30 20 100 30 Maximum Turn-Off Time msec (8) 40 40 40 30 20 (1) SOLID STATE AUXILIARY CONTACTS Description Normally Open Sufx 2x,1x Normally Closed Sufx x1 Operating Voltage Range (47-63Hz) Vrms (9) 18-280 18-280 Transient Overvoltage Vpk 600 600 Maximum Load Current Arms 1 1 Minimum Load Current mA 5 5 Maximum Surge Current Apk 1 Cycle 60Hz 40 40 Maximum Surge Current Apk 1 Cycle 50Hz 38 38 2 2 Maximum I t for Fusing (8.33msec) A sec 6.7 6.7 2 2 Maximum I t for Fusing (10msec) A sec 7.2 7.2 Maximum Off-State Leakage Current Rated Voltage mArms 0.1 5 mA Minimum Off-State dv/dt Maximum Rated Voltage V/sec 500 500 Maximum Delay to Turn-On msec (7) 30 80 Maximum Turn-Off Time msec 40 40 (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) (10) 3750 Vrms 9 Minimum Insulation Resistance ( 500 VDC) 10 Ohms Maximum Capacitance, Input/Output 20 pF Ambient Operating Temperature Range (11) -30 to 80 C Ambient Storage Temperature Range -40 to 100 C Weight (typical) 2 Controlled Legs (6.9 oz 197 g ) / 3 Controlled Legs (8.0 oz 228 g ) Housing Material UL94 V-0 Housing Color Black and Light Gray LED Status Indicator (color) (12) Forward (Green) / Reverse (Amber) Short Circuit Current Rating (13) 100kA MTBF (Mean Time Between Failures) at 40C ambient temperature (14) 1,398,000 hours (159 years) MTBF (Mean Time Between Failures) at 60C ambient temperature (14) 390,000 hours (44 years) Pollution Degree 2 Protection Degree (15) IP20 Humidity 85% non-condensing Control and Auxiliary Contact Terminal Screw Torque Range (in-lb/Nm) 12 / 1.36 Load Terminal Screw Torque Range (in-lb/Nm) 15 / 1.7 2 Input Terminal Wire Capacity 18-12 AWG (IEC 1-4 mm ) (stranded /solid) 2 Output Terminal Wire Capacity 18-10 AWG (IEC 1-6 mm ) (stranded /solid) Do not forget to visit us at: www.crydom.com Copyright 2018 Crydom Inc. Specifications subject to change without notice.