MENT1220 Universal 220 Watt Series Medical Switch-Mode Power Supply 3Year Warranty Universal Input 100Vac 240Vac 12V to 48V Single Output Models up to 220W Desktop Style/Non-vented case - No internal fan Ribbed Case Surface to improve cooling Energy Star 2.0, Level V Certified to Medical (UL/IEC/EN60601-1) and ITE (UL/IEC/EN60950-1) Standards IPX1 Rated Enclosure Class I and Class II input versions available. Modified and Custom Designs Specifications All Specifications are typical at nominal input, full load at 25C unless otherwise stated. A C Input 100-240VAC, +/-10%, 47-63 Hz single phase MTBF >100,000 hours (calculated) Input Current 115VAC: 4A max, 230VAC: 1.5A max Hold-up Time 21 ms min. 100VAC Inrush Current 75A max. 264VAC, Cold Start Overvoltage Protection 130% of nominal output voltage Input Fuses Internal 6.3A Primary Current Fuses are provided Overload Protection 110-150% of full rated load, auto-recovery PFC, Harmonics IEC61000-3-2 Short Circuit Protection Hiccup Mode, auto-recovery Earth Leakage Current <350A typical 264VAC, 50Hz Switching Frequency 50-120kHz, variable Efficiency 88% typical Medical Safety Standards EN/IEC/UL60601-1 No Load Power <0.5W ITE Safety Standards EN/IEC/UL60950-1 Transient Response 5ms max. for 50% load step Isolation: Input-Output: 4KVac, Input-GND: 1.5KVac Max deviation is 5% Output-GND: 700Vdc Output Voltage See chart Operating Temp. 0 - 70C, derate above 40C to 60% of full rated load at 70C Line Regulation: +/-0.5% max Storage Temperature -20 to +85C Load Regulation +/-3% max Relative Humidity 5% to 95%, non-condensing Minimum Load Not required Altitude 0 to 10,000 ft Ripple and Noise 1% pk-pk max., 20MHz BW, differential mode Case Material Black 94V-0 rated Polycarbonate Turn-on Time 3 sec. maximum 115VAC Case Dimensions Desktop Style: 8.4 x 4.25 x 1.85 Output Connections See chart and outline drawing Weight 1200g 1 of 3 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: info slpower.com www.slpower.com MENT1220 Universal 220W Series Medical Switch-Mode Power Supply 3Year Warranty OUTPUT PARAMETERS Model Number Output Volts Output Current (max) Max Watts Ripple (Vp-p max) MENT1220A1251F01 12V 15.0A 180W 120mV MENT1220A1551F01 15V 13.0A 195W 150mV MENT1220A1851F01 18V 11.7A 210W 240mV MENT1220A2451F01 24V 9.2A 220W 240mV MENT1220A2851F01 28V 7.9A 220W 280mV MENT1220A3251F01 32V 6.9A 220W 320mV MENT1220A4851F01 48V 4.6A 220W 480mV Model Number Key MENT 1 220 A VV 51 F 01 Model Configuration:01 = Standard. 02 and higher indicates a modified model. Input Connector: = IEC320 C14 grounded. See below for other options (consult factory for availability) Output Connector:51 - Molex 39-01-2060 or equivalent. Other options available, consult factory. Output Voltage:12 = 12Vdc,15 = 15Vdc,18 = 18Vdc,24 = 24Vdc,28 = 28Vdc,32 = 32Vdc,48 = 48Vdc Model Configuration: = Model Configuration Output Power:220 = 220 Watts of Outputs1 = Single Output Product Family: = Medical, = External,N = Model Series Designator EMI/EMC Compliance Conducted Emissions FCC Part 15, Subpart B, EN55011 Class B Radiated Emissions FCC Part 15, Subpart B, EN55011 Class B Voltage Fluctuations EN61000-3-3, Line Flicker Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz.. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 crit. A, 100Vac 60Hz, 40%/5 cycles with 70% full load. Line Frequency Harmonics EN61000-3-2, Class A Input Receptacle Options Output Connector = IEC320 C8 = IEC320 C14 = IEC320 C18 Ungro u n d e d G r o u n d e d U n g r o u n d e d See outline drawings below for connector information and pinout. 2 of 3 SL Power Electronics Corp 6050 King Drive Ventura, CA 93003 Phone 805.486.4565 Fax 858.712.2040 Email: info slpower.com www.slpower.com