Models & Ratings Max Output Output Voltage V1 Output Current (1) (2,3) Efficiency Model Number Power Min Nominal Max Min Max 5000 W 0 VDC 60 VDC 63 VDC 0.0 A 83.3 A 93% HPT5K0TS060 5000 W 0 VDC 100 VDC 105 VDC 0.0 A 50.0 A 93% HPT5K0TS100 5000 W 0 VDC 200 VDC 210 VDC 0.0 A 25.0 A 93% HPT5K0TS200 Notes 1. Measured with 480 VAC input and full load. 2 2. Standard models include PMBus, CANopen and RS485 interfaces. RS485 default is full duplex. RS485 half duplex can be configured via I C or factory configured on request. To replace RS485 with RS232 or UART, contact sales. 3. For medical applications with 4000 VAC isolation test add suffix -M. Installation Class 3 surge only. 4. USB interface available to enable RS485 and RS232 communcation with GUI. Part number XP PS MANAGER INT. AC-DC Power Supplies HPT5K0 Series 5000 Watts 3 Phase 180 to 528 VAC Input - 3 Wire & Earth xxx Series High Efficiency - up to 94% Programmable Output Voltage (0-105%) Programmable Output Current (0-110%) Parallel Operation Analog & Digital Interfaces Multiple Digital Protocols - PMBus, CANopen, MODBUS & SCPI Fully Featured Signals & Controls Graphical User Interface (GUI) Dimensions: 5V/2A Standby Supply HPT5K0: 3 Year Warranty 13.00 x 5.00 x 5.00 (330.2 x 127.0 x 127.0 mm) The HPT5K0 series offers users both output voltage and output current programming, via voltage, 2 I C PMBus, RS485 and CANopen in a very high efficiency, high power density 5 kW chassis mount package. Options are available for RS232 or UART. Measuring just 13.0 x 5.0 x 5.0, the HPT5K0 also features active current sharing, remote on/off, remote sense and a power OK signal. The 5V/2A standby output is available whenever the mains supply is present. Input www.xppower.com 1 Characteristic Minimum Typical Maximum Units Notes & Conditions 180 264 VAC 3 kW output power max Input Voltage 342 528 VAC 5 kW output power max, 3 wire & earth 580 VAC For 5 s Input Frequency 47 63 Hz Power Factor 0.96 Complies with EN61000-3-2 for Class A Input Current 10/11 A Per phase, 342 VAC (5 kW)/180 VAC (3 kW) Inrush Current 60 A Per phase, 528 VAC (5 kW) 1.0 528 VAC/60 Hz Earth Leakage Current mA 3.3 528 VAC/60 Hz, single fault Input Protection F16A / 500 V fuse fitted in each phase Loss of phase Shutdown after 0.5s, auto recovery AC-DC Power Supplies HPT5K0 Series 5 Input Derating 4 3 2 1 180 342 528 580 Input Voltage (VAC) Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 0 210 VDC See Models and Ratings table Output Set Tolerance 0.5 % Nominal voltage irrespective of set voltage. +5 V Standby Tolerance 3 % 5V Standby Of nominal, slew rate <40 ms 10-105% & 105-10%. Output Voltage Program 0 105 % Max frequency of voltage program is 0.5 Hz 0-5% load, 0.67 Hz 5-10% load, 1Hz 10-20% load, 3 Hz 20-100% load Output Voltage Adjust 10 % Of set output via potentiometer 105% of nominal max. Output Current Program 0 110 % Of nominal Minimum Load 0A No minimum load required Start Up Delay 1.8 2s Under all load and line conditions Start Up Rise Time 40 ms 20 22 380 VAC at 5000 W and 25 C Hold Up Time ms 40 44 180 VAC at 3000 W and 25 C 0.5 Of nominal voltage Line Regulation % 0.5 5V Standby 1 0-100% or 100-0% load Load Regulation % 2 5V Standby Deviation with a 50-75-50% load change. Output returns to Transient Response 3% within 1% in less than 500 s Of nominal voltage/5V Standby. Measured with 20 MHz Ripple & Noise 1/2.5 % bandwidth limited oscilloscope 0-50 C. Overshoot 5% Turn on & turn off Of nominal voltage, latching. Cycle AC to reset. Overvoltage Protection 110 120 % No protection for 5V Standby Overtemperature Protection Auto resetting thermal protection Set current limit point. Constant current characteristics. Max current limit is 108% 3% of maximum rated current. % Overload Protection 3 For low line (180-264 VAC), constant power characteristic set (of max load) at 3.4 kW until current limit point is reached. 5V Standby: <5 A max Constant current characteristics. Short Circuit Protection 5V Standby: Foldback characteristic < 5 A max. Temperature Coefficient 0.03 of max load %/C Remote Sense Compensates for 1% max of nominal voltage per lead, 2% of total nominal voltage drop. Not fitted on HPT5K0TS200 Output Voltage Programming Output Current Programmes 110 105 100 100 80 80 60 60 40 40 20 20 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Vprog (V) Iprog (V) w ww.xppower.com 2 Output Voltage (% of nominal) Output Power (kWatts) Output Current (% of nominal) 5 s max.