17 January 2014 Page 1 FEATURES 42W Constant Voltage LED Driver LEDWV-42 Series High Efficiency (Up to 89%) Class 2 Output (See Notes) Active Power Factor Correction (Typical 0.95) Waterproof (IP66) and Damp Location Certified Short Circuit, Overload and Over Temperature Protection UL/cUL 8750, EN61347, SELV Equivalent & CE Certified RoHS Compliant SPECIFICATION Model LEDWV-042S012PS (1) LEDWV-042S024PS (1) LEDWV-042S036PS (1) LEDWV-042S048PS (2) Rated Voltage 12V (9) 24V (9) 36V (9) 48V (9) No Load Voltage 16V 28V 40V 52V Rated Power 42W 42W 42W 42W Ripple & Noise (10) 3V 4V 4V 4V Current Range 0-3500mA 0-1750mA 0-1160mA 0-875mA Line Regulation 2% Load Regulation 3% Overshoot/Undershoot 10% Turn-on Delay (Typ.) 0.6S (110Vac), 0.3S (220Vac) Voltage Range 90 ~ 305 Vac Frequency Range 47Hz / 63Hz Efficiency (3) 84.0% 86.0% 87.0% 89.0% Inrush Current 70A Max. (At 230Vac input 25 Cold Start. Duration=100 s) AC Current (Typ.) 0.6A 100 VAC 0.3A 220 VAC THD 20% Max. Short Circuit Hiccup mode, no damage shall occur and the power supply shall restart when the fault condition is removed Overload Hiccup mode, at 140% (Typ.) of rated load the power supply shall restart when the fault condition is removed Hiccup mode, when the case temperature reaches 110 the power supply shut down when the case temperature cools to 75 , the power Over Temperature supply will restart. Operational -35C ~ 70C (See derating Curve) Temperature Range Storage - 40 ~ +85C Operational 10% RH to 100% RH Humidity Storage 5% RH to 100% RH UL8750, UL1012, UL1310 Class 2, CSA C22.2 NO. 223-M91 Class 2 CE (EN 61347-1, EN61347-2-13) Safety Standards No load Power 6 W Dissipation Conducted & EN 55015 Class B Radiated EMI Harmonic Current EN 61000-3-2 EN 61000-3-3, EN 61000-4-2 (4), EN 61000-4-3 (5), EN 61000-4-4 (6), EN 61000-4-5 (7), EN 61000-4-6 (8), EN 61000-4-8, EN 61000- EMS 4-11, EN 61547 ANSI/IEEE C62.41: Class A Operation (See notes below) 321,000 hours (Measured at 110Vac input, 80% Load and 25C ambient temperature (MIL-HDBK-217F)) MTBF Life Time 120,000 Hours (Measured at 110Vac input, 80% Load and 60C case temperature- see curve below) Dimension (L*W*H) 95 70 32 (mm) - 3.74 2.76 1.26 (inch) Weight 350 g Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Others Safety & EMC Environment Protections Input Output 17 January 2014 Page 2 Notes 1. Class 2 US and Canada 2. Class 2 US only 3. Typical at 220VAC 4. Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge 5. Radio-Frequency Electromagnetic Field Susceptibility Test-RS 6. Electrical Fast Transient / Burst-EFT: level 3, criteria A 7. Surge Immunity Test: AC Power Line: line to line 2 kV, line to earth 4 kV 8. Conducted Radio Frequency Disturbances Test-CS 9. Output voltage tolerance +/-5% 10. Max. Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10uF electrolytic capacitor. Mechanical Specification LEDWV-042SxxxPS Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777