NEMA Contactors & Starters 33-79 Freedom February 2007 Catalog Number Selection Catalog Number Selection Table 33-91. Freedom Catalog Numbering System A N 1 4 A N 0 A 3 E 0 0 5 33 Device Type C396 Electronic Overload FLA Range (FNVR & FVR Only) A = Starter C = Contactor Frame A NEMA Size 00 Frame G NEMA Size 2 P05 = 0.1 0.5A 008 = 1.6 8.0A 002 = 0.4 2.0A 032 = 6.4 32A Standard 005 = 1.0 5.0A 045 = 9.0 45A 008 = 1.6 8.0A E = IEC N = NEMA Frame B NEMA Size 0 Frame K NEMA Size 3 P05 = 0.1 0.5A 110 = 22 110A 002 = 0.4 2.0A Device Assembly Configuration Frame N NEMA Size 4 005 = 1.0 5.0A 150 = 30 150A 008 = 1.6 8.0A 70 = Multi-Speed 032 = 6.4 32A 1 = Non-reversing Frame S NEMA Size 5 5 = Reversing 300 = 60 300A Frame D NEMA Size 1 Frame T NEMA Size 6 P05 = 0.1 0.5A 600 = 120 600A OLR Type 002 = 0.4 2.0A Frame U NEMA Size 7 4 = Starter w/C396 Electronic Overload 005 = 1.0 5.0A 10C = 200 1000A 5 = Contactor only no overload relay 008 = 1.6 8.0A 6 = Starter w/C306 Bi-Metal OLR 032 = 6.4 32A Frame V NEMA Size 8 7 = Starter w/C316 Bi-Metal OLR 15C = 300 1500A 8 = Starter w/IT. SSOLR C396 Electronic OLR Designation (FVNR & FVR Only) Contactor Frame Size 3E = Standard C396 OLR, SEL Reset, SEL Class NEMA Continuous C306 Bi-Metallic OLR Designation Size Amp Rating NEMA Enclosure C = NEMA Size 00, 0 A = 00 9 N = Open B = NEMA Size 1, 2 B = 0 18 N/R = NEMA Size 3, 4 D = 1 27 For Starters B = NEMA Size 5 G = 2 45 C = Starter NEMA Size 6 K = 3 90 B = Mounting Option NEMA Size 7, 8 N = 4 135 S = 5 270 0 = Horizontal T = 6 540 V = Vertical AC Coil Suffix U = 7 810 For Contactors Only V = 8 1215 Suffix Coil Volts and Hertz 2 = 2-pole A = 120/60 or 110/50 3 = 3-pole B = 240/60 or 220/50 4 = 4-pole C = 480/60 or 440/50 5 = 5-pole D = 600/60 or 550/50 E = 208/60 H = 277/60 J = 208 240/60 K = 240/50 L = 380 415/50 N = 550/50 T = 24/60, 24/50 U = 24/50 V = 32/50 W = 48/60 Y = 48/50 For Contactor Only orders, add B to end of Catalog Number if NEMA Size 00 2, 6. 3E, 4E feature set only. Uses CT with C396 45 mm OLR, 3E, 4E feature set only. Not required. NEMA Sizes 00 and 0 only. NEMA Sizes 00 and 0 only. Sizes 1 8 are 24/60 only. CA08102001E For more information visit: www.eaton.comNEMA Contactors & Starters 33-85 Freedom February 2007 Starters 3-Phase Non-reversing and Reversing, Full Voltage, Bi-Metallic Overload Product Selection When Ordering Supply Catalog Number Heater pack number (see selection 33 Size 3 table, Pages 33-117 33-118) or full load Vertical current. Size 0 Reversing Non-reversing Size 1 Starter Starter Reversing Starter Table 33-101. Type AN16/AN56 NEMA Manual or Automatic Reset Overload Relay Non-reversing and Reversing NEMA Continuous Service-Limit Maximum UL Horsepower 3-Pole 3-Pole Vertical Price Size Ampere Current Non-reversing Reversing Reversing U.S. 1-Phase 3-Phase Rating Rating 115V 230V 208V 240V 480V 600V Catalog Price Catalog Catalog (Amperes) Number U.S. Number Number 00 9 11 1/3 1 1-1/2 1-1/2 2 2 AN16AN0 C AN56AN0 C 0 18 21 1 2 335 5 AN16BN0 C AN56BN0 C AN56BNV0 1 27 32 2 3 7-1/2 7-1/2 10 10 AN16DN0 B AN56DN0 B AN56DNV0 2 45 52 3 7-1/2 10 15 25 25 AN16GN0 B AN56GN0 B AN56GNV0 3 90 104 25 30 50 50 AN16KN0 AN56KN0 AN56KNV0 4 135 156 40 50 100 100 AN16NN0 AN56NN0 AN56NNV0 5 270 311 75 100 200 200 AN16SN0 B AN56SN0 B 6 540 621 150 200 400 400 AN16TN0 C AN56TN0 C 7 810 932 200 300 600 600 AN16UN0 B AN56UN0 B 8 1215 1400 400 450 900 900 AN16VN0 B AN56VN0 B Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection, Pages 33-117 33-118. Underscore ( ) indicates coil sufx required, see Table 33-102. Maximum horsepower rating of starters for 380V 50 Hz applications: NEMA Size 00 0 1234 5678 Horsepower 1-1/2 5 10 25 50 75 150 300 600 900 The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller. Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN56VND0CB. Table 33-102. AC Sufx Code Magnet Coils AC or DC Coil Volts and Hertz Code Sufx Starter coils listed in this section also have a 50 Hz rating as shown in the 120/60 or 110/50 A adjacent table. Select required starter 240/60 or 220/50 B 480/60 or 440/50 C by Catalog Number and replace the 600/60 or 550/50 D magnet coil alpha designation in the 208/60 E Catalog Number ( ) with the proper 277/60 H Code Sufx from the adjacent table. 208 240/60 J 240/50 K For Sizes 00 2 and 5 8, the magnet coil alpha designation will be the next 380 415/50 L NEMA Size 0 550/50 N to last digit of the listed Catalog Num- Cat. No. AN56BN0AC 24/60, 24/50 T ber. EXAMPLE: For a 380V, 50 Hz coil, 24/50 U change AN16BN0 C to AN16BN0LC. 32/50 V For all other sizes, the magnet coil 48/60 W alpha designation will be the last digit 48/50 Y of the listed Catalog Number. NEMA Sizes 00 and 0 only. NEMA Sizes 00 and 0 only. Sizes 1 8 are For DC Magnet Coils, see Accessories, 24/60 only. Pages 33-98 33-99. Technical Data Pages 33-89 33-91 Overload Relay . Page 33-113 Dimensions Pages 33-106 33-108 Special Modications . Page 33-100 Accessories Pages 33-92 33-100 Heater Packs . Pages 33-117 33-118 Discount Symbol 1CD1 CA08102001E For more information visit: www.eaton.com