Digital Fiber Amplifier Unit E3X-DA-S/MDA CSM E3X-DA-S MDA DS E 15 5 Advanced Fiber Amplifier Units Features a Power Tuning function that optimizes light reception at the press of a button. APC circuits to suppress LED aging degradation used with 4- element LEDs. 2-channel models achieve the thinne st* profile in the industry, at only 5 mm per channel. 2-channel models also offer AND/OR control output. The E3X-MDA0 with two channels supports an EtherCAT Sensor Communications Unit or CompoNet Sensor Communications Unit. * (Based on July 2012 OMRON investigation.) Note: As of the end of March 2017, orders of the E3X-DA SE-S/ Be sure to read Safety Precautions on DA -S/DA AT-S/DA RM-S/DA TW-S are no longer page 15. accepted. As of the end of March 2019, orders of the E3X-DA AN-S/ DAH -S/DAB -S/DAG -S are no longer accepted. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Models available for a wide variety of applications at manufacturing sites Industry Leading Two Amplifiers Loaded in a Small Body 2-channel models Two amplifiers are loaded in a 10 mm-wide body. Checking LCD substrates seating and alignment Space usability can be approximately doubled. In addition, approximately 40% of the energy can be saved. (compared to the value per channel of the former model) 2-channel models 20mm E3X-MDA 10mm Advanced Analog High-speed and High-resolution Analog Output Supports Wide Variety of Applications Output Models Analog Control Output High-speed and High Resolution The voltage in the range of 1 to 5 V is output according to the incident Detection modes can be switched in accordance with applications. level (digital display). Wide variety of applications is possible including High-speed response of 80 s (super-high-speed mode) supports the positioning control or difference detection with multiple levels. positioning controls that require high-speed control. Sheet Displacement ON/OFF Analog 1E3X-DA-S/MDA Ordering Information Fiber Amplifier Units Amplifier Units with Cables (2 m) Refer to Dimensions on page 17. Model Item Appearance Functions NPN output PNP output Single-function models --- E3X-DA11SE-S 2M * E3X-DA41SE-S 2M * Standard models E3X-DA11-S 2M * E3X-DA41-S 2M * Green LED E3X-DAG11-S 2M * E3X-DAG41-S 2M * Mark-detecting models Timer, Response speed change (multiple color light Blue LED E3X-DAB11-S 2M * E3X-DAB41-S 2M * sources) Infrared LED E3X-DAH11-S 2M * E3X-DAH41-S 2M * External-input models Remote setting, counter, differential operation E3X-DA11RM-S 2M * E3X-DA41RM-S 2M * Twin-output models Area output, self-diagnosis, differential operation E3X-DA11TW-S 2M * E3X-DA41TW-S 2M * Advanced models ATC function models ATC (Threshold value automatic correction) E3X-DA11AT-S 2M * E3X-DA41AT-S 2M * Analog output models Analog output models E3X-DA11AN-S 2M * E3X-DA41AN-S 2M * 2-channel models AND/OR output E3X-MDA11 2M E3X-MDA41 2M * As of the end of March 2017, orders of the E3X-DA SE-S/DA -S/DA AT-S/DA RM-S/DA TW-S are no longer accepted. As of the end of March 2019, orders of the E3X-DA AN-S/DAH -S/DAB -S/DAG -S are no longer accepted. Amplifier Units with Wire-saving Connectors Refer to Dimensions on page 18. Model Item Appearance Functions NPN output PNP output Single-function models --- E3X-DA6SE-S *1 E3X-DA8SE-S *1 Standard models E3X-DA6-S *1,2 E3X-DA8-S *1,2 Green LED E3X-DAG6-S *1,2 E3X-DAG8-S *1,2 Mark-detecting models Timer, Response speed change (multiple color light Blue LED E3X-DAB6-S *1,2 E3X-DAB8-S *1,2 sources) Infrared LED E3X-DAH6-S *1,2 E3X-DAH8-S *1,2 External-input models Remote setting, counter, differential operation E3X-DA6RM-S *1,2 E3X-DA8RM-S *1,2 Advanced models Twin-output models Area output, self-diagnosis, differential operation E3X-DA6TW-S *1,2 E3X-DA8TW-S *1,2 ATC function models ATC (Threshold value automatic correction) E3X-DA6AT-S *1 E3X-DA8AT-S *1 2-channel models AND/OR output E3X-MDA6 *2E3X-MDA8 *2 *1. As of the end of March 2017, orders of the E3X-DA SE-S/DA -S/DA AT-S/DA RM-S/DA TW-S are no longer accepted. As of the end of March 2019, orders of the E3X-DA AN-S/DAH -S/DAB -S/DAG -S are no longer accepted. *2. These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-CN02 Connector without a Cable for the Wire-saving Connector. Amplifier Units with Connectors for EtherCAT or CompoNet Sensor Communications Units Refer to Dimensions on page 19. Applicable Sensor Item Appearance Functions Model Communications Unit E3X-ECT AND/OR output 2-channel model E3X-MDA0 E3X-CRT Ratings and Specifications Control output/input Functions Response Interfer- Differen- Type Light source ON/OFF Analog Power time Input Timer ence pre- tial detec- counter ATC output output tuning vention tion Single-function models 1 ms --- --- Only Red LED --- --- --- --- --- 50 s to main Standard models 4ms E3X-DA G-S Green LED Mark- 50 s to Only detecting 3X-DA B-S Blue LED --- --- --- --- --- 4ms main models E3X-DA H-S Infrared LED Twin-output 50 s to Only models 4ms main (1 line) --- External-input 80 s to --- Ad- Main + models 4ms vanced Red LED sub ATC function 130 s to models (2 lines) --- --- models 4ms 80 s to Only Analog output --- --- 4ms main (1 line) Main + main 130 s to 2-channel models Red LED (2 inde- --- --- --- --- --- 4ms pendent lines) 2