Sensing Band F03-15 CSM F03-15 DS E 1 4 Ideal for harsh electrical room environments that are dusty and humid. For installation in locations requiring insulated materials. Indicates models that allow free cutting. Ordering Information Name Model number Remarks Liquid Leakage Sensing Band F03-15-1M Length: 1m F03-15-2M Length: 2m F03-15-5M Length: 5m F03-15-10M Length: 10m F03-15-15M Length: 15m F03-15-20M Length: 20m F03-15-25M Length: 25m F03-15-50M Length: 50m F03-15-75M Length: 75m F03-15-100M Length: 100m Sensing Band stickers F03-25 30 Stickers per bag Note: 1. Specify the cable length for F03-15 from the list above. 2. The cables can be cut. Specifications Sheath Flexible, transparent vinyl chloride Core SUS304 stainless steel Ambient operating temperature 15 to 50 C Weight Approx. 48 g (1 m) Dimensions (Unit: mm) Sensing Band Sensing Band Stickers Appearance F03-25 Appearance (Stainless steel wire Structure Electrode pairs 0.3 mm x 12-wire braided cable) Structure 252 (0.5) (5) 8 (3) 151 25 (1) Flexible, transparent vinyl chloride Adhesive tape 333 (3 pairs/m) Material: SUS304 1F03-15 Chemical Resistivity for F03-16PE/-16PT Material Sheath Core Material Sheath Core Polyethylene Fluoroplastic SUS316 Polyethylene Fluoroplastic SUS316 Water AA A Toluene CB B Acetone CA A Phenol BBA Ammonia AA A Butanol BA--- Ethanol BA A Fluorine AAC Hydrochloric acid AA C Hexane CA --- Hydrogen peroxide solutionAA A Benzene CA A Xylene BA A Methanol BAA Cyclohexane CA --- Sulfuric acidCA B Trichloroethylene CA A Phosphoric acidABB Note: 1. A: Not affected at all or only very slightly affected. B: Slightly affected but, depending on the conditions, sufficient for use. C: Affected but may still be used. (Replace the Sensing Band immediately after detection.) 2. The F03-16PE Sensing Band is made from the following materials. Core: SUS316 Insulated sheath: Polyethylene 3. In order to prevent secondary fire damage, consider the effect of the atmosphere of the environment and the solution to be detected on the Sensing Band. 4. If the Sensing Band changes shape or color when a liquid is detected, replace the Sensing Band. Connecting the Sensing Band Bending the Sensing Band Interval Between Stickers To change the direction of the Sensing Band, bend the Sensing Band When securing the Sensing Band with Stickers, attach the Stickers at in one or two places where the core is not exposed. intervals of 20 to 30 cm in places where the core is not exposed. Sensing Band 20 to 30 cm Sticker Note: 1. When using the F03-26PES (adhesive-tape model), be sure to wipe all moisture, oil, and dust from the surface to which the Sticker is to be attached. Failure to do so may result in insufficient adhesion, and the Sticker may peel away from Bent in 2 places Bent in 1 place the surface. Note: Bend the Sensing Band approximately 4 cm (i.e., twice the dis- 2. When using the F03-26PEN (screw model), before installing tance between places where the core is exposed) away from the Sensing Band, it is necessary to perform stud welding. places where a Sticker is attached. If the Sensing Band is bent For details on the pitch of the studs, refer to the information at places further away than this, the Sensing Band may come on the dimensions of Sensing Band Stickers. away from the surface. 3. Commercially available screwdrivers can be used. It is rec- ommended, however, that either a 210-350/01 screwdriver Stripping and Connecting Terminals or a 209-132 operating tool to connect jumpers, both manu- factured by Wago Japan, is used. Contact