Timer Interval Indicator K3HB-P CSM K3HB-P DS E 16 3 Digital Time Interval Meter for Measuring Passing Speed, Time, or Cycle between Two Points. Visual confirmation of judgement results through display colors that switch between red and green. *1 Measures Wide Range of Pulse Interval Times Measures, calculates, and displays pulse intervals between two points. Wide range for pulse interval measurements, from 10 ms to 3,200 s, max. Six Measurement Operations, Including Passing Speed, Time, and Cycle Measurement between Two Points One Digital Time Interval Meter has six measurement functions, to support a variety of pulse interval measurement applications. Select the best function for your application from the following: Passing speed, cycle, time difference, time band, measuring length, and interval. DeviceNet models added to the series. *2 *1 Visual confirmation of judgement results is not supported on models that do not have an For the most recent information on models that have been certified for output or models that do not support DeviceNet. safety standards, refer to your OMRON website. You can change the display color by setting it, but you cannot switch it based on the judgement results. *2 DeviceNet models have a depth of 97 mm. Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-P K3HB-P - 15 1 234 5 2. Sensor Power Supply/Output Type Code 1. Input Sensor Code NB: NPN input/voltage pulse input None: None PB: PNP input CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC10%, 80 mA) (See note 1.) 5. Supply Voltage L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply 100-240 VAC: 100 to 240 VAC (12 VDC10%, 80 mA) (See note 2.) 24 VAC/VDC: 24 VAC/VDC L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) Optional Board A: Sensor power supply (12 VDC 10%, 80 mA) FLK1A: Communications (RS-232C) + Sensor power supply Sensor Power Supply/Output Boards (12 VDC10%, 80 mA) (See note 2.) FLK3A: Communications (RS-485) + Sensor power supply K33- (12 VDC10%, 80 mA) (See note 2.) 2 Note: 1. CPA can be combined with relay outputs only. 2. Only one of the following can be used by each Digital Indicator: RS-232C/RS- Relay/Transistor Output Boards 485 communications, a linear output, or DeviceNet communications. 3. Relay/Transistor Output Type Code K34- None: None 3 C1: Relay contact (H/L: SPDT each) C2: Relay contact (HH/H/LL/L: SPST-NO each) Event Input Boards T1: Transistor (NPN open collector: HH/H/PASS/L/LL) T2: Transistor (PNP open collector: HH/H/PASS/L/LL) BCD :BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL) K35- DRT: DeviceNet (See note 2.) 4 A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code None: None 1: 5 inputs (HOLD/RESET), NPN open collector 2 : 8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), NPN open collector 3: 5 inputs (HOLD/RESET), PNP open collector 4 : 8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), PNP open collector There is no bank selection forNon andDeviceNe types ofTransistor Output Type Cod. Note: The following combinations are not possible. Communications (FLK A) + DeviceNet (DRT) Communications (FLK A) + BCD output (BCD) Linear current/voltage (L A) + DeviceNet (DRT) 1K3HB-P Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model Y92A-49N K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings Supply voltage 100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC range Power consumption 100 to 240 VAC: 18 VA max. (max. load) (See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC 10%, 80 mA (for models with external power supplies only) Event inputs Hold input NPN open collector or no-voltage contact signal (See note 2.) ON residual voltage: 2 V max. Reset input ON current at 0 : 4 mA max. Bank input Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. Output ratings Relay output 250 VAC, 30 VDC, 5 A (resistive load) (depends on Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations the model) Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V no output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green)) Main functions Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, teaching, dis- play value selection, display color selection, key protection, bank selection, display refresh period, maximum/mini- mum hold, reset Ambient operating temperature 10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature 25 to 65C (with no icing or condensation) Altitude 2,000 m max. Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De- Accessories viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 2