Product Information

3UG4501-1AW30

3UG4501-1AW30 electronic component of Siemens

Datasheet
Level Controllers LIQUID LEVEL MONITOR, 5-100 KOHMS,120V

Manufacturer: Siemens
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 112.268 ea
Line Total: USD 112.27

9 - Global Stock
Ships to you between
Fri. 03 May to Thu. 09 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
2 - Global Stock


Ships to you between Thu. 09 May to Mon. 13 May

MOQ : 1
Multiples : 1
1 : USD 247.066
10 : USD 241.822
25 : USD 239.0965
50 : USD 237.636
100 : USD 236.348
1000 : USD 236.3365

9 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1
1 : USD 112.268
5 : USD 110.76

     
Manufacturer
Product Category
Series
Product Type
Type
Mounting Style
Analogue / Digital
Display Type
Output Type
Size
Features
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
3UG4511-1AP20 electronic component of Siemens 3UG4511-1AP20

Module: voltage monitoring relay; phase sequence; DIN; SPDT; IP20
Stock : 12

3UG4511-1BP20 electronic component of Siemens 3UG4511-1BP20

Module: voltage monitoring relay; phase sequence; DIN; DPDT; IP20
Stock : 6

3UG4501-2AA30 electronic component of Siemens 3UG4501-2AA30

Module: level monitoring relay; conductive fluid level; DIN
Stock : 0

3UG4501-2AW30 electronic component of Siemens 3UG4501-2AW30

Module: level monitoring relay; conductive fluid level; DIN
Stock : 0

3UG4511-1AN20 electronic component of Siemens 3UG4511-1AN20

Module: voltage monitoring relay; phase sequence; DIN; SPDT; IP20
Stock : 0

3UG4511-1AQ20 electronic component of Siemens 3UG4511-1AQ20

Module: voltage monitoring relay; phase sequence; DIN; SPDT; IP20
Stock : 0

3UG4511-1BN20 electronic component of Siemens 3UG4511-1BN20

Module: voltage monitoring relay; phase sequence; DIN; DPDT; IP20
Stock : 0

3UG4511-1BQ20 electronic component of Siemens 3UG4511-1BQ20

Module: voltage monitoring relay; phase sequence; DIN; DPDT; IP20
Stock : 0

3UG4511-2AN20 electronic component of Siemens 3UG4511-2AN20

Module: voltage monitoring relay; phase sequence; DIN; SPDT; IP20
Stock : 0

3UG4511-2AP20 electronic component of Siemens 3UG4511-2AP20

Module: voltage monitoring relay; phase sequence; DIN; SPDT; IP20
Stock : 0

Image Description
3UG4511-1BP20 electronic component of Siemens 3UG4511-1BP20

Module: voltage monitoring relay; phase sequence; DIN; DPDT; IP20
Stock : 6

3UG4512-1BR20 electronic component of Siemens 3UG4512-1BR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 14

3UG4614-1BR20 electronic component of Siemens 3UG4614-1BR20

Module: voltage monitoring relay; DIN; DPDT; OUT1:250VAC/3A; IP20
Stock : 14

3UG4622-1AA30 electronic component of Siemens 3UG4622-1AA30

Module: current monitoring relay; AC/DC current; DIN; SPDT; 24VAC
Stock : 4

3UG4651-1AW30 electronic component of Siemens 3UG4651-1AW30

Module: speed monitoring relay; speed; 24÷240VAC; DIN; SPDT
Stock : 6

VSB-24STB electronic component of Fujitsu VSB-24STB

VSB-24STB MINIATURE PCB RELAY
Stock : 761

VKP-11F42 electronic component of TE Connectivity VKP-11F42

General Purpose Relays SPST OPEN 40A 12VDC
Stock : 6

VKP-15F72 electronic component of TE Connectivity VKP-15F72

Power relay VKP (open and sealed)
Stock : 0

SM3A21-24VDC electronic component of Elcomp SM3A21-24VDC

SM3A21-24VDC MINIATURE PCB RELAY
Stock : 50

401670036 electronic component of Omron 401670036

DIP Switches/SIP Switches MTKM-0750-0500
Stock : 0

Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Overview Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Net- work and voltage faults can be detected early and rectified be- fore far greater damage ensues. Depending on the version, the relays monitor phase sequence, phase failure with and without N conductor monitoring, phase unbalance, undervoltage or overvoltage. Phase unbalance is evaluated as the difference between the greatest and the smallest phase voltage relative to the greatest phase voltage. Undervoltage or overvoltage exists when at least one phase voltage deviates by 20 % from the set rated system voltage or the directly set limit values are overshot or undershot. The rms value of the voltage is measured. With the 3UG46 17 or 3UG46 18 relay, a wrong direction of rota- tion can also be corrected automatically. Function 3UG45 11 monitoring relays 3UG45 12 monitoring relays The 3UG45 11 phase sequenced relay monitors the phase se- The 3UG45 12 line monitoring relay monitors three-phase net- quence in a three-phase network. No adjustments are required works with regard to phase sequence, phase failure and phase for operation. The device has an internal power supply and unbalance of 10 %. Thanks to a special measuring method, a works using the closed-circuit principle. If the phase sequence phase failure is reliably detected in spite of the wide voltage at the terminals L1-L2-L3 is correct, the output relay picks up af- range from 160 ... 690 V AC and feedback through the load of up ter the delay time has elapsed and the LED is lit. If the phase se- to 90 %. The device has an internal power supply and works us- quence is wrong, the output relay remains in its rest position. ing the closed-circuit principle. No adjustments are required. When the mains voltage is switched on, the green LED is lit. If the Note: When one phase fails, connected loads (motor windings, phase sequence at the terminals L1-L2-L3 is correct, the output lamps, transformers, coils, etc.) create a feedback voltage at the relay picks up. If the phase sequence is wrong, the red LED terminal of the failed phase due to the network coupling. Be- flashes and the output relay remains in its rest position. If a phase cause the 3UG45 11 relays are not resistant to voltage feedback, fails, the red LED is permanently lit and the output relay drops. such a phase failure is not detected. Should this be required, then the 3UG45 12 monitoring relay must be used. Note: The red LED is a fault diagnostic indicator and does not show the current relay status. The 3UG45 12 monitoring relay is suitable for line frequencies of 50/60 Hz. Phase failure Correct phase sequence L1-L2-L3 L2-L3 L1-L2-L3 L1-L2-L3 11/14 11/14 ON 11/12 11/12 21/24 21/24 21/22 21/22 LED rd OFF ON OFF Wrong phase sequence Phase loss Wrong phase sequence L3-L2-L1 L3-L2-L1 11/14 11/14 11/12 11/12 OFF 21/24 21/24 21/22 21/22 LED rd OFF FLASH OFF Phase sequence Siemens 2010 59 NSB0 01566a NSB0 01565a NSB0 01568a NSB0 01567aMonitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring 3UG45 13 monitoring relays 3UG46 14 monitoring relays The 3UG45 13 line monitoring relay monitors three-phase net- The 3UG46 14 line monitoring relay has a wide voltage range works with regard to phase sequence, phase failure, phase un- and an internal power supply. The device is equipped with a dis- balance and undervoltage of 20 %. The device has an internal play and is parameterized using three buttons. It monitors three- power supply and works using the closed-circuit principle. The phase networks with regard to phase unbalance from 5 ... 20 %, hysteresis is 5 %. The integrated response delay time is adjust- phase failure, undervoltage and phase sequence. The hystere- able from 0 ... 20 s and responds to undervoltage. If the direction sis is adjustable from 1 ... 20 V. In addition the device has a re- is incorrect, the device switches off immediately. Thanks to a sponse delay and ON-delay from 0 ... 20 s in each case. The in- special measuring method, a phase failure is reliably detected in tegrated response delay time responds to phase unbalance and spite of the wide voltage range from 160 ... 690 V AC and feed- undervoltage. If the direction is incorrect, the device switches off back up to 80 % through the load. When the mains voltage is immediately. Thanks to a special measuring method, a phase switched on, the green LED is lit. If the phase sequence at the failure is reliably detected in spite of the wide voltage range from terminals L1-L2-L3 is correct, the output relay picks up. If the 160 ... 690 V AC and feedback up to 80 % through the load. phase sequence is wrong, the red LED flashes and the output The 3UG46 14 monitoring relay can be operated on the basis of relay remains in its rest position. If a phase fails, the red LED is either the open-circuit or closed-circuit principle and with man- permanently lit and the output relay drops. ual or auto RESET. Note: With the closed-circuit principle selected The red LED is a fault diagnostic indicator and does not show the current relay status. The 3UG45 13 monitoring relay is suitable Wrong phase sequence for line frequencies of 50/60 Hz. L3-L2-L1 Phase failure and undervoltage 11/14 11/12 L1-L2-L3 L2-L3 L1-L2-L3 Hysteresis 5 % 21/24 -20 % 3~ n 21/22 11/14 Phase failure 11/12 L1-L2-L3 L2-L3 L1-L2-L3 21/24 21/22 11/14 NSB0 01569a LED rd 11/12 OFF ON OFF ON OFF 21/24 Phase loss Delay 21/22 Wrong phase sequence Undervoltage L3-L2-L1 < Hysteresis x-y 11/14 11/12 11/14 11/12 21/24 21/22 21/24 LED rd 21/22 OFF FLASH OFF Delay Phase sequence onDelay Unbalance Hysteresis > Asy 2 % 0 % 11/14 11/12 21/24 21/22 Delay onDelay Siemens 2010 60 NSB0 01570a NSB0 01571a NSB0 01576a NSB0 01578a NSB0 01577a

Tariff Desc

8536.49.00 TC 17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC 8909066 having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 low profile, OTHER THAN reed relays, being EITHER of the following
a) height NOT exceeding 21.24mm
b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following
a) one, two or three contacts
b) maximum continuous contact current rating of NOT less than 15A
c) maximum contact voltage rating of NOT less than 380V
d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts having ANY of the following:
a) spring loaded terminals
b) plug-in screw terminals
c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following
a) maximum switching current NOT exceeding 5A AC or DC
b) switching voltage NOT exceeding 250V AC or DC
c) body dimensions NOT exceeding 31mm x 36mm x 19mm

8536.49 TC 8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics
a) trip time NOT exceeding 5 s at 6 times full load current
b) manual reset
c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following
a) normally closed main poles
b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8536.49.00 solid state having an operating voltage NOT exceeding 600VAC or 300VDC but NOT including protective monitoring TC 9320885

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted