Data Sheet GE HW/HC004/005/006 Series DC-DC Power Module 18-36Vdc & 36-75Vdc Input 1.0V-5Vdc Output 4A - 6A Output Current Features RoHS Compliant Compliant to RoHS EU Directive 2011/65/EU (Z versions) Compliant to RoHS EU Directive 2011/65/EU under exemption 7b (Lead solder exemption). Exemption 7b will expire after June 1, 2016 at which time this produc twill no longer be RoHS compliant (non-Z versions) Delivers up to 6A Output current 5V (4A), 3.3V (5A), 2.5V 1.0V (6A each) High efficiency 89% at 5.0V full load Low Output voltage- supports migration to future IC supply voltages down to 1.0V Applications Low output ripple and noise Wireless Networks Small Size and low profile Distributed power architectures 47.2mm x 29.5mm x 8.5mm Optical and Access Network Equipment (1.86 x 1.16 x 0.335 in) Enterprise Networks Surface mount or Through hole (TH) Latest generation ICs (DSP, FPGA, ASIC) and Remote On/Off Microprocessor powered applications Output overcurrent/Over voltage protection Over temperature protection Options Single Tightly regulated output Remote On/Off logic (positive or negative) Output voltage adjustment trim 10% Surface Mount (-S Suffix) Wide operating temperature range (-40C to 85C) Additional Vout+ pin (-3 Suffix) Meets the voltage insulation requirements for ETSI 300- 132-2 and complies with and is Licensed for Basic Insulation rating per EN 60950 CE mark meets 73/23/EEC and 93/68/EEC directives UL* 60950-1Recognized, CSA C22.2 No. 60950-1-03 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Description The HW/HC series power modules are isolated dc-dc converters that operate over a wide input voltage range of 18 to 36 Vdc (HC) or 36 to 75 Vdc (HW) and provide one precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, e.g. typical efficiency of 87% 3.3V/5A, 86% at 2.5V/6A. Built-in filtering for both input and output minimizes the need for external filtering. These open frame modules are available either in surface-mount (-S) or in through-hole form. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards October 2, 2015 2012 General Electric Company. All rights reserved. Data Sheet GE HW/HC004/005/006 Series DC-DC Power Module 18-36Vdc & 36-75Vdc Input 1.0V-5Vdc Output 4A - 6A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage HC V -0.3 50 Vdc IN Continuous HW V -0.3 80 Vdc IN Transient (100ms) HW V -0.3 100 Vdc IN, trans Operating Ambient Temperature All TA -40 85 C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 C I/O Isolation Voltage (100% factory tested) All 2250 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage HC V 18 24 36 Vdc IN HW VIN 36 54 75 Vdc Maximum Input Current HC IIN,max 1.75 Adc (V =0V to 75V, I =I) HW I 0.85 Adc IN O O, max IN,max 2 2 Inrush Transient All It 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12 H source impedance VIN=0V to 75V, All 5 mAp-p I = I see Figure 9) O Omax Input Ripple Rejection (120Hz) All 50 dB EMC, EN55022 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of complex power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet for further information. October 2, 2015 2012 General Electric Company. All rights reserved. Page 2