Product Information

L261

L261 electronic component of AEMC

Datasheet
TRMS SIMPLE LOGGER, 600V AC/DC

Manufacturer: AEMC
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 666.7682 ea
Line Total: USD 666.7682

11 - Global Stock
Ships to you between
Thu. 05 Oct to Wed. 11 Oct
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
16 - Global Stock


Ships to you between Thu. 05 Oct to Wed. 11 Oct

MOQ : 1
Multiples : 1

Stock Image

L261
AEMC

1 : USD 729.7086

     
Manufacturer
AEMC
Product Category
Unclassified
Brand
AEMC
Data Logger Type
AC & DC Voltage
No. Of Channels
1Channels
Reading Capacity
240000
Data Logger Functions
Voltage (TRMS)
Input Voltage
0 V to 600 V
Sample Rate
64 Samples / Cycle
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
MN103 electronic component of AEMC MN103
AC CURRENT PROBE, MULTIMETER 10A TO 100A
Stock : 21
MN114 electronic component of AEMC MN114
AC CURRENT PROBE
Stock : 14
2118.73 electronic component of AEMC 2118.73
KELVIN PROBE
Stock : 17
2118.79 electronic component of AEMC 2118.79
KELVIN CLIP, MICRO OHMMETER, 10FT
Stock : 2
1017.84 electronic component of AEMC 1017.84
KELVIN CLIP
Stock : 2
BR07 electronic component of AEMC BR07
RESISTANCE DECADE BOX, 1 OHM-11.11111MOHM
Stock : 2
6416 electronic component of AEMC 6416
Test Leads BASICTEST LEAD SET
Stock : 1
SR661 electronic component of AEMC SR661
AC AMMETER, CLAMP, 100mA to 2kA
Stock : 20
4000D-24 W/6 LEAD electronic component of AEMC 4000D-24 W/6 LEAD
AC AMMETER, HANDHELD, 0.2A-4000A, 24"
Stock : 1
2960.21 electronic component of AEMC 2960.21
RECHARGEABLE BATTERY PACK 9.6V (REPLACEMENT FOR MODELS 1060, 5050, 5060, 5070, 4630, 6470/6470-B, 6471, 6472 & 6505) 28M9652
Stock : 2
Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

PH1-03-UA electronic component of Adam PH1-03-UA

Single Row 3 Position GOLD FLASH .235" Solder TAIL .100" PIN Header
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

Special DATA LDAOGGERSTA LOGGERS product features Simple LoggerSimple Logger II TRMS V II TRMS Clamp-On Currentoltage 600Vca /dc Model L261 & 850Vdc Model L481 One channel loggers for voltage measuring, monitoring and troubleshooting SPECIFICATIONS IP 40 Rated MODELS L261 L481 ELECTRICAL Channels One FEATURES Input Connection Two recessed 4mm safety banana jacks TRMS voltage recording up to 600Vca /dc Measurement Range 0 to 600Vac /dc -850 to 850Vdc (Model L261) Resolution 0.1V Bipolar voltage recording up to 850Vdc Accuracy (50/60Hz) 0 to 5V: unspecified 0 to 5V: unspecified 5 to 50V: 5 to 50V: (Model L481) (0.5% of Reading + 1V) (0.5% of Reading + 1V) AC: 64 samples per cycle and 50 to 600V: 50 to 850V: DC: 8 samples per sec (Model L261) (0.5% of Reading + 0.5V) (0.5% of Reading + 0.5V) Programmable storage rates from Input Impedance 40M 8 every second to 1 every day Sample Rate 64 samples/cycle Maximum of 8 per second 4 user selectable storage modes Storage Rate Programmable from 8 every second to 1 every day Stores up to 240,000 measurements in Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM ) and Alarm non-volatile memory Recording Length 15 minutes to 8 weeks, programmable using DataView Powered by standard Alkaline batteries Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory and Lightweight, compact, fits anywhere will be retained even if the battery is low or removed. 5 LED indicators quickly and clearly Communication USB 2.0 optically isolated display logger status Power Source 2 x 1.5V AA-cell Alkaline batteries (included) Includes FREE DataView software Battery Life 100 hours to >45 days for data storage, real-time display, (dependent on sample rate and recording length) analysis and report generation MECHANICAL Optically isolated USB 2.0 Dimensions 4.94 x 2.75 x 1.28 (125 x 70 x 32mm) communication cable included Weight (with battery) 6.4 oz (181g) EN 61010-1 300V CAT IV 600V CAT III Case UL94-V0 Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz) APPLICATIONS ( MODEL L261) Shock IEC 68-2-27 (30G) Surge and Sag recording Drop IEC 68-2-32 (1m) Long term supply monitoring Industrial, commercial and residential monitoring Monitor voltage harmonics Find intermittent voltage problems PRODUCT INCLUDES Machine monitoring APPLICATIONS ( MODEL L481) Set of two color-coded 5 ft voltage leads, color-coded alligator clips (red/black), Rail voltage monitoring USB type A to 5 pin Mini-B, and USB Long term supply monitoring stick supplied with DataView software and user manual. Find intermittent voltage problems Machine monitoring Windmill monitoring CATALOG NO. DESCRIPTION 2126.05 Simple Logger II Model L261 (1-Channel, TRMS, 600Vca /dc , DataView software) 2126.25 Simple Logger II Model L481 (1-Channel, 850Vdc , DataView software) www.aemc.com Technical Assistance (800) 343-1391 DATAVIEW Software for Data Loggers Data Analysis and Reporting Software for Data Loggers Typical DataView Functional Displays Configure all data logger functions of the Simple Logger II Models Displa y and analyze real-time data on your PC Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more Create and store a complete libr ary of configur ations that can be uploaded to the logger as needed Zoom in and out and pan through sections of the graph to analyze the data Download, display and analyze recorded data Display waveforms, trend graphs, harmonics (AC models) and text summaries Quick and simple configuration of all functions and Create custom views and reports settings from one dialog box. Print reports using standard or custom templates you design Free software upgrades are available on our website www.aemc.com Configure all alarm functions with straightforward selections. Real-time display of all active inputs on computer through DataView software. Real-time view of trend, waveform and status screens. www.aemc.com Technical Assistance (800) 343-1391