Product Information

TGP110

TGP110 electronic component of Aim-TTi

Datasheet
GENERATOR, PULSE , 10MHZ

Manufacturer: Aim-TTi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 559.3483 ea
Line Total: USD 559.35

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1

Stock Image

TGP110
Aim-TTi

1 : USD 559.3483

     
Manufacturer
Product Category
Brand
Signal Generator Type
No. Of Channels
Bandwidth
Manufacturer Warranty
Plug Type
Svhc
External Depth
External Height
External Width
Safety Category
Supply Voltage Max
Supply Voltage Min
Supply Voltage Range
Weight
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
CPX400SP electronic component of Aim-TTi CPX400SP

PSU, 1CH, 60V, 20A, PROGRAMMABLE
Stock : 30

PFM-CASE electronic component of Aim-TTi PFM-CASE

CASE, SOFT, FOR PFM3000
Stock : 0

EL561R electronic component of Aim-TTi EL561R

POWER SUPPLY, 1CH, 56V, 1.1A, ADJUSTABLE
Stock : 0

EX2020R electronic component of Aim-TTi EX2020R

Power supply: laboratory; Channels:1; 0÷20VDC; 0÷20A; Plug: EU, UK
Stock : 2

PL068P electronic component of Aim-TTi PL068P

POWER SUPPLY, 1CH, 6V, 8A, ADJUSTABLE
Stock : 0

PL068P(G) electronic component of Aim-TTi PL068P(G)

POWER SUPPLY, 1CH, 6V, 8A, ADJUSTABLE
Stock : 1

LDH400P electronic component of Aim-TTi LDH400P

ELECTRONIC DC LOAD, 400W, 16A, 500V
Stock : 1

PL155-P(G) electronic component of Aim-TTi PL155-P(G)

Power supply: programmable laboratory; Ch: 1; 0÷15VDC; 0÷5A; 1mV
Stock : 0

PL303QMD-P(G) electronic component of Aim-TTi PL303QMD-P(G)

Power supply: programmable laboratory; Ch: 3; 0÷30VDC; 0÷3A; 0÷3A
Stock : 0

MX100QP electronic component of Aim-TTi MX100QP

Power supply: programmable laboratory; Ch: 4; 0÷35VDC; 0÷6A; 0÷6A
Stock : 4

Image Description
ST10003B electronic component of US Sensor ST10003B

US Sensor Inrush Current Limiters
Stock : 0

TG330 electronic component of Aim-TTi TG330

FUNCTION GENERATOR/COUNTER, 1CH, 3MHZ
Stock : 2

B57238S259M electronic component of TDK B57238S259M

Inrush Current Limiters CORRECT MFG PN 871-B57238S0259M000
Stock : 1

B57364S209M electronic component of TDK B57364S209M

Inrush Current Limiters CORRECT MFG PN 871-B57364S0209M000
Stock : 3

B57236S100M electronic component of TDK B57236S100M

Inrush Current Limiters CORRECT MFG PN 871-B57236S0100M000
Stock : 3

33510B electronic component of Keysight 33510B

SIGNAL GENERATOR, 2CH, FUNCTION, 20MHZ
Stock : 0

TGP3151 electronic component of Aim-TTi TGP3151

PULSE GENERATOR, 1-CH, ARB/FUNC, 50MHZ
Stock : 0

TG315 electronic component of Aim-TTi TG315

FUNCTION GENERATOR, 1CH, 3MHZ
Stock : 0

TG1006 electronic component of Aim-TTi TG1006

FUNCTION GENERATOR, 1CH, DDS, 10MHZ
Stock : 1

MM35 0R560-DIN electronic component of Ametherm MM35 0R560-DIN

Inrush Current Limiters 35mm .5ohms 60A DUAL DIN BLADE TERM
Stock : 3

CYAN MAGENTA YELLOW BLACK CYAN MAGENTA YELLOW BLACK TGP110 10MHz pulse generator with delay An essential instrument Wide pulse range The generation of pulses for the stimulus and control of elec- The TGP110 can generate pulse widths in the range 50ns to 5s. tronic systems is beyond the capability of all but the most so- There are eight overlapping decade ranges with vernier control phisticated of function generators. within each range. The architecture of a dedicated pulse generator enables it to The period range is 100ns to 10s, equivalent to a repetition rate generate pulses of a set width regardless of the repetition rate range of 10MHz to 0.1Hz. Delay is independently adjustable offering duty cycles which can extend down to 1 in 100 million. over the same range as pulse width. AIM & THURLBY THANDAR INSTRUMENTS In addition to continuous operation, single or multiple pulses A complement switch inverts the mark-space polarity. can be generated in response to trigger or gating signals with TGP110 precisely defined timing relationships. Squarewave and double pulse A dedicated pulse-waveform output amplifier provides flat top In square mode, squarewaves are generated at a frequency set pulses with fast rise and fall times at variable amplitude. by the period controls alone. This provides a convenient means of generating variable period edges where the pulse width is Variable delay unimportant, for example. The TGP110 offers selectable delay between the sync output In double pulse mode, a second pulse is generated within every and pulse output. In triggered mode this also sets the delay be- period at a set delay after the start of the first pulse. The delay is tween a trigger signal and the start of the pulse. independently adjustable. PERIOD, PULSE WIDTH, DELAY INPUTS Each parameter is variable within 8 overlapping decade ranges with a GATE/TRIG INPUT vernier providing continuously variable control within each range. Frequency range: DC - 10MHz PERIOD Signal range: TTL threshold max. input 10V. Range: 100nsec to 10sec (10MHz to 01Hz). Min. pulse width: >30nsec. Jitter: <0.1%. Input Impedance: Typically 10k . PULSE WIDTH Range: 50nsec to 5sec OUTPUTS Jitter: <0.1%. DELAY 50 OUTPUT Range: 50nsec to 5sec Amplitude: Two switch selectable ranges of 01V - 10V and 1V - 10V from 50 . (50mV to 500mV and 500mV to 5V into 50 ). Adjustable within ranges by a single TRIGGER, GATE turn vernier. Rise/Fall Times: RUN Typically 10nsec into 50 load. Maximum 15ns. Aberrations: Typically <5% for output set at >20% of range maxi- Normal operational mode in which pulses are generated continuously at 0.1Hz to 10MHz. mum, into 50 . TRIGGERED AUX OUTPUT DC to 10MHz pulse train in synchronism with external trigger pulses Duplicates 50 output but at a fixed CMOS/TTL level. pulse width determined by pulse width controls. Trigger can be gener- SYNC OUTPUT ated manually from front panel button. Amplitude: A positive going pulse at CMOS/TTL level. GATED Timing: Leading edge starts >20nsec before the TTL/50 01Hz to 10MHz pulse train, parameters set by period and pulse width output transition. controls, starts synchronously with leading edge of gate input. Last pulse Duration: Typically 30nsec. is completed at the end of gating period. Gating signal can be generated COMPLEMENT SWITCH manually from front panel button. Inverts the AUX and 50 outputs. PULSE MODES GENERAL NORMAL PULSE Power: 230V or 115V AC nominal 50/60Hz, adjustable inter- One pulse is generated each period. The delay setting is ignored. nally operating range 14% of nominal 20VA max. SQUAREWAVE Size: 140 x 220 x 230mm (HxWxD) 10MHz pulse generator with delay 01Hz to 10MHz squarewave, frequency set by the period controls. Weight: 1.6kg (3.5lb) Pulse width and delay settings ignored. Operating Range: + 5C to 40C, 20-80% RH. Mark : Space ratio: 1:1 10%. Storage Range: - 40C to 70C DOUBLE PULSE Safety: Complies with EN61010-1. 0.1Hz to 10MHz frequency range A second pulse is generated after a delay set by the delay controls the EMC: Complies with EN55081-1 and EN50082-1. delay is related to the leading edge of the first pulse. 50ns minimum pulse width fully variable pulse delay DELAYED PULSE A pulse is generated after a delay set by the delay controls the delay is Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves related to rising edge of the trigger signal. the right to alter specifications without prior notice. Squarewave, double pulse and delayed pulse modes Free-run, gated and triggered modes Designed and built in Europe by: 50 output, variable 0.1V to 10V TTL and sync outputs Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE29 7DR England Tel: +44 (0)1480 412451 Fax: +44 (0) 1480 450409 Email: info aimtti.com Web: www.aimtti.com 82100-0066 Iss. 1ACYAN MAGENTA YELLOW BLACK CYAN MAGENTA YELLOW BLACK TGP110 10MHz pulse generator with delay An essential instrument Wide pulse range The generation of pulses for the stimulus and control of elec- The TGP110 can generate pulse widths in the range 50ns to 5s. tronic systems is beyond the capability of all but the most so- There are eight overlapping decade ranges with vernier control phisticated of function generators. within each range. The architecture of a dedicated pulse generator enables it to The period range is 100ns to 10s, equivalent to a repetition rate generate pulses of a set width regardless of the repetition rate range of 10MHz to 0.1Hz. Delay is independently adjustable offering duty cycles which can extend down to 1 in 100 million. over the same range as pulse width. AIM & THURLBY THANDAR INSTRUMENTS In addition to continuous operation, single or multiple pulses A complement switch inverts the mark-space polarity. can be generated in response to trigger or gating signals with TGP110 precisely defined timing relationships. Squarewave and double pulse A dedicated pulse-waveform output amplifier provides flat top In square mode, squarewaves are generated at a frequency set pulses with fast rise and fall times at variable amplitude. by the period controls alone. This provides a convenient means of generating variable period edges where the pulse width is Variable delay unimportant, for example. The TGP110 offers selectable delay between the sync output In double pulse mode, a second pulse is generated within every and pulse output. In triggered mode this also sets the delay be- period at a set delay after the start of the first pulse. The delay is tween a trigger signal and the start of the pulse. independently adjustable. PERIOD, PULSE WIDTH, DELAY INPUTS Each parameter is variable within 8 overlapping decade ranges with a GATE/TRIG INPUT vernier providing continuously variable control within each range. Frequency range: DC - 10MHz PERIOD Signal range: TTL threshold max. input 10V. Range: 100nsec to 10sec (10MHz to 01Hz). Min. pulse width: >30nsec. Jitter: <0.1%. Input Impedance: Typically 10k . PULSE WIDTH Range: 50nsec to 5sec OUTPUTS Jitter: <0.1%. DELAY 50 OUTPUT Range: 50nsec to 5sec Amplitude: Two switch selectable ranges of 01V - 10V and 1V - 10V from 50 . (50mV to 500mV and 500mV to 5V into 50 ). Adjustable within ranges by a single TRIGGER, GATE turn vernier. Rise/Fall Times: RUN Typically 10nsec into 50 load. Maximum 15ns. Aberrations: Typically <5% for output set at >20% of range maxi- Normal operational mode in which pulses are generated continuously at 0.1Hz to 10MHz. mum, into 50 . TRIGGERED AUX OUTPUT DC to 10MHz pulse train in synchronism with external trigger pulses Duplicates 50 output but at a fixed CMOS/TTL level. pulse width determined by pulse width controls. Trigger can be gener- SYNC OUTPUT ated manually from front panel button. Amplitude: A positive going pulse at CMOS/TTL level. GATED Timing: Leading edge starts >20nsec before the TTL/50 01Hz to 10MHz pulse train, parameters set by period and pulse width output transition. controls, starts synchronously with leading edge of gate input. Last pulse Duration: Typically 30nsec. is completed at the end of gating period. Gating signal can be generated COMPLEMENT SWITCH manually from front panel button. Inverts the AUX and 50 outputs. PULSE MODES GENERAL NORMAL PULSE Power: 230V or 115V AC nominal 50/60Hz, adjustable inter- One pulse is generated each period. The delay setting is ignored. nally operating range 14% of nominal 20VA max. SQUAREWAVE Size: 140 x 220 x 230mm (HxWxD) 10MHz pulse generator with delay 01Hz to 10MHz squarewave, frequency set by the period controls. Weight: 1.6kg (3.5lb) Pulse width and delay settings ignored. Operating Range: + 5C to 40C, 20-80% RH. Mark : Space ratio: 1:1 10%. Storage Range: - 40C to 70C DOUBLE PULSE Safety: Complies with EN61010-1. 0.1Hz to 10MHz frequency range A second pulse is generated after a delay set by the delay controls the EMC: Complies with EN55081-1 and EN50082-1. delay is related to the leading edge of the first pulse. 50ns minimum pulse width fully variable pulse delay DELAYED PULSE A pulse is generated after a delay set by the delay controls the delay is Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves related to rising edge of the trigger signal. the right to alter specifications without prior notice. Squarewave, double pulse and delayed pulse modes Free-run, gated and triggered modes Designed and built in Europe by: 50 output, variable 0.1V to 10V TTL and sync outputs Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE29 7DR England Tel: +44 (0)1480 412451 Fax: +44 (0) 1480 450409 Email: info aimtti.com Web: www.aimtti.com 82100-0066 Iss. 1A

Tariff Desc

8533.29.00 19 No - Resistors -Other Free 19 No --ELECTRICAL RESISTORS (INCLUDING RHEOSTATS AND POTENTIOMETERS), OTHER THAN HEATING RESISTORS: Other
AIM-TTI
AIM-TTI INSTRUMENTS
TTI
TTI Aim

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted