TR11 Series UL1077 Recognized Supplementary Protector/ Circuit Breaker for Equipment Applications: Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to E209569 up to 12 Amps overload conditions. Operating Characteristic Current Rating (A) 0.1 - 16A Standard Current Rating (A) 0.1, 0.25, 0.5, 0.9, 1.0, 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.7, 3.0, 3.3, 4.0, 5.0, 6.0, 6.5, 7.0, 8.0, 9.0, (min) 60 10.0, 12.0, 15.0, 16.0 30 20 Rated Voltage 240V AC, 50/60Hz, 50V DC / 24V DC (VDE) (As per EN 60934) Initial insulation resistance (500V DC) > 100 M ohms. 10 (As per EN 60934) Dielectric strength 1.5 KV for One minute. 5 6 I - AC up to 9.0A n Overload Switching Capacity (As per EN 60934) 4 I - DC up to 12.0A n 1 60A AC/DC Max. - from 10.0A to 12.0A (S) 50 Maximum Breaking Capacity 8x I AC/DC for <6.0A n 60A AC/DC MAX. for > 6.0A 20 Power Loss 1 - 2 Watts 10 Operating Temperature Maximum 60C Ambient 5 Operational Life at 2xI 1000 Cycles n Rated Conditional Short Circuit 1000 Amps PC 1,240V AC, 24V DC, Ref.: EN60934 2 Current Capacity I (PC1) SC: 1KA, C1, 240V AC 50V DC nc1 Ref.: EN60934 Ref.: CSA22.2 No.235-04, UL-1077 1 Tripping Current Code TC TC 2Ref.: CSA22.2 No. 235-04 0.5 Overload Rating OL0 240V AC, 50V DC, Ref.: CSA22.2 No. 235-04 Application Type General Industrial Ref.: CSA22.2 No. 235-04 Method of Tripping Thermal TO Trip Free 0.2 Type of Actuation Reset Type R 0.1 Application Standards CSA 22.2 No. 235-04, UL-1077, EN 60934 1.05 1.32 23485 10 Weight aprox. 11g Multiple of Rated Current Approvals 0.1 - 16.0A 0.5 - 12.0A 240V AC 50V DC 240V AC 24V DC Rated current < 6 A > 6 A ORDERING INSTRUCTIONS Ambient 23C Temperature Time Current Characteristics: PRODUCT CURRENT RATING TYPE 0.1 TO 16.0A The standard characteristic is valid for MOUNTING NUT ambient temperatures of +23C. If the device is to be used in an ambient temperature other than +23C, allowances must be made when selecting the current rating according to the following guidelines: Ambient temp.C -20 -5 0 +10 +20 +30 +40 +50 +60 Correction Factor 0.8 0.88 0.9 0.96 1 1.05 1.12 1.2 1.3 * Example: Normal Continuous Current 1.8A Ambient Temperature 40C Correction Factor 1.12 Recommended Current Rating 1.8 x 1.12 = 2.016 Select the nearest 2.0A Terminal configuration option X is available up to 12A special order only. Consult Altech for ordering. * Note: TR11-C Series stocked contact Altech for availability. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 80 Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers Trip time TR-11 Dimensions & Mounting Options Central Mounting Wing Clips Wing Clip Types Snap Fitting Body Mounting PCB Mounting Slider Printing for Current Rating Slider Color with Trip Band Accessories Dimensions in mm (to convert to inches multiply by 0.03937) Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 81 Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers