Telaire T5100-LED Series Low-Cost Wall Mount CO Transmitter 2 The new Telaire T5100-LED series is a new low cost, Gas permeable, water resistant CO diffusion filter 2 high performing CO transmitter for the building prevents particulate and water contamination of the 2 controls market. It works seamlessly with building sensor. automation systems, and allows you to simply and effectively control fresh air into a ventilated space Locking screw secures cover and sensor to the to regulated standards, providing immediate energy mounting bracket for tamper resistance. savings. Sensors are shipped factory calibrated. Features: Modern enclosure Patented, Absorption Infrared Gas sensing engine Low-cost provides high accuracy in a compact low cost package. Reliable (20 years of low-cost infrared sensor manufacturing) Patented ABC Logic self-calibration system eliminates the need for manual calibration in most Available CO and Temperature output options: applications. 2 Voltage 0-10V or 0-5V (switch selectable) Or current 4-20 mA Lifetime CO calibration guarantee when using ABC 2 Logic. UIP software compatible for customizations Mounting plate with two-piece terminal blocks CE, RoHS, REACH and WEEE compliant provide quick, easy wiring. Lifetime calibration warranty Two enclosure sizes for regional acceptance Amphenol Advanced SensorsControlled Ventilation *C0 accuracy statement excludes standard gas used for Ventilation is an important part of maintaining a comfortable, 2 calibration that has an accuracy of 2%. In addition, there is a healthy, productive environment for people. Improper potential digital to analog error of up to 2%. ventilation can have a negative impact on occupant health and performance, increase the risk from litigation, and/ or waste energy. Demand-controlled ventilation using CO Warranty 2 sensors prevents energy losses from over-ventilation while 24 months on mechanical defects Calibration - lifetime warranty (ABC Logic on.) maintaining indoor air quality. The most energy savings potential is in buildings where occupancy fluctuates during a 24-hour period. Numerous organizations now require and/ Certifications or recommend CO -based ventilation control in different CE EMC, RoHS, REACH and WEEE compliant 2 commercial HVAC applications. Some utility companies also offer rebates to building owners for installing CO sensors. 2 Signal Update Every 5 seconds Wall mount sensors are used to control a specific area such as a conference room, classroom, meeting hall, etc. The CO Warm-up Time 2 Telaire 5000 Ventostat series are easy to install and have a < 2 minutes (operational) clean, modern look that suits most indoor environments. 10 minutes (maximum accuracy) Operating Conditions 32F to 122F (0C to 50C) Wall Mount Specifications 0 to 95% RH, non-condensing Sensing Method Storage Conditions Non-dispersive infrared (NDIR) absorption -40F to 158F (-40C to 70C) Gold-plated optics Patented ABC Logic self calibration algorithm Flammability Classification UL94 5VA CO Measurement Range 2 0 to 2000 ppm (0 ppm = 0 V, 4 mA) Output CO Accuracy Analog (Temperature and CO ) 2 2 30 ppm or 3% of the reading shown, whichever is higher * 0 to 5 V, or 0 to 10 V switch selectable (100 output impedance) Or 4 to 20 mA (RL maximum 500 ) Active Temperature Accuracy /Range Voltage and current outputs are not available 0-50C (32-122F) simultaneously 1C from 15-30C (1.8F from 59 to 86F) Digital to analog error 2% Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, polarity protected Sensor Accuracy & Field Calibration *AHRAE regulation 62 states maximum indoor CO2 level of CO ABC Logic Self Calibration 2 1000 ppm T5100-LED sensors employ the patented ABC (Automatic Background Calibration) Logic self-calibration system. ABC Power Consumption Logic virtually eliminates the need for manual calibration Typical 0.7 W at nominal voltage of 24V AC RMS in applications where the indoor CO level drops to outside 2 levels during unoccupied periods (e.g. during evening hours). Temperature Dependence ABC Logic is a special software routine in the sensor that 0.2% FS per C (0.11% per F) remembers the background readings for 14 consecutive evenings, calculates if there is a sensor drift, and then corrects for it. Stability <2% of FS over life of sensor (15 years) With ABC Logic enabled, the sensor will typically reach its operational accuracy after 25 hours of continuous operation Pressure Dependence at a condition that is exposed to ambient reference levels. 0.135% of reading per mm Hg Sensors will maintain accuracy specifications with ABC Logic enabled, given that it is at least three times in 14 days