Precision Triaxial Inclinometer and Accelerometer with SPI Data Sheet ADIS16210 FEATURES GENERAL DESCRIPTION Triaxial, digital inclinometer system The ADIS16210 iSensor is a digital inclinometer system that 180 measurement range, roll and pitch axes provides precise measurements for both pitch and roll angles 90 gravity axis over a full orientation range of 180. It combines a MEMS tri- 0.1 relative accuracy axial acceleration sensor with signal processing, addressable user Triaxial, digital accelerometer, high accuracy registers for data collection/programming, and a SPI-compatible 1.7 g measurement range serial interface. In addition, the production process includes unit 0.05 axis-to-axis alignment specific calibration for optimal accuracy performance. It also Digital internal temperature measurements offers digital temperature sensor and power supply measurements Digital internal power supply measurements together with configuration controls for in-system calibration, Programmable user calibration options sample rate, filtering, alarms, I/O configuration, and power Single command, frame alignment management. Manual accelerometer bias correction The MEMS sensor elements are bound to an aluminum core for Programmable operation and control tight platform coupling and excellent mechanical stability. An Sample rate/filtering internal clock drives the data sampling system, which eliminates Alarm conditions and indicator output the need for an external clock source. The SPI and data buffer Input/output: data ready, alarm, general-purpose structure provide convenient access to accurate sensor data and Power management functions configuration controls. SPI-compatible serial interface The ADIS16210 is available in a 15 mm 24 mm 15 mm Serial number and device ID module that provides mounting tabs with M2-sized mounting Single-supply operation: 3.0 V to 3.6 V holes and a flexible, edge terminated connector interface. It has Calibrated temperature range: 40C to +85C an extended operating temperature range of 40C to +125C. 15 mm 24 mm 15 mm package with flexible connector APPLICATIONS Platform control, stabilization, and alignment Tilt sensing, inclinometers, and leveling Motion/position measurement Monitor/alarm devices (security, medical, safety) Navigation FUNCTIONAL BLOCK DIAGRAM DIO1 DIO2 RST VDD ADIS16210 POWER SELF TEST I/O ALARMS GND MANAGEMENT TRIAXIAL MEMS SENSOR CS CONTROL CONTROLLER REGISTERS SCLK SPI TEMPERATURE PORT SENSOR DIN CORRECTION OUTPUT DIGITAL INCLINE AND REGISTERS FILTER CALIBRATION ALIGNMENT DOUT SUPPLY Figure 1. Rev. C Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. rights of third parties that may result from its use. Specifications subject to change without notice. No Tel: 781.329.4700 20112016 Analog Devices, Inc. All rights reserved. license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. Technical Support www.analog.com 09593-001ADIS16210* PRODUCT PAGE QUICK LINKS Last Content Update: 09/22/2017 COMPARABLE PARTS DESIGN RESOURCES View a parametric search of comparable parts. ADIS16210 Material Declaration PCN-PDN Information EVALUATION KITS Quality And Reliability ADIS16210 Daughter Board Symbols and Footprints ADIS16ACL1 Breakout Board DISCUSSIONS EVAL-ADIS Evaluation System EVAL-ADIS2 Evaluation System View all ADIS16210 EngineerZone Discussions. DOCUMENTATION SAMPLE AND BUY Data Sheet Visit the product page to see pricing options. ADIS16210: Precision Triaxial Inclinometer and Accelerometer with SPI Data Sheet TECHNICAL SUPPORT Submit a technical question or find your regional support number. DOCUMENT FEEDBACK Submit feedback for this data sheet. This page is dynamically generated by Analog Devices, Inc., and inserted into this data sheet. A dynamic change to the content on this page will not trigger a change to either the revision number or the content of the product data sheet. This dynamic page may be frequently modified.