NLP65 Series Data Sheet Single, dual and triple output Total Power: 65 - 75 W Input Voltage: 85-264 VAC 120-370 VDC* of Outputs: Single, dual, triple SPECIAL FEATURES Universal Input 3 x 5 footprint Low profile fits 1U applications EN61000-3-2 compliance option (HCC) Overvoltage and short circuit protection 65 W with free air convection cooling EN55022, EN55011 conducted emissions level B EN61000-4-2,-3,-4, -5, -6 Electrical Specifications immunity compliant Input RoHS compliant Input voltage range: Universal input (see Note 2) 85-264 Vac LPX80 enclosure kit available NLP65-76xx version only 120-370 Vdc 2 year warranty Input frequency range: 47-63 Hz 17 A max. Input current: 120 Vac SAFETY (cold start) 230 Vac 32 A max VDE0805/EN60950-1 Safety ground leakage current: 120 Vac, 60 Hz 0.7 mA File No. 1040100-3336-0096 230 Vac, 50 Hz 1.4 mA License No. 114404 Input current: 120 Vac, with PFC 1.4 A UL 60950-1 230 Vac, with PFC 0.51 A rms cUL 60950-1 120 Vac, without PFC 1.40 A rms CCC 60950-1 230 Vac, without PFC 0.80 A rms CE LVD Directive Input fuse: UL/IEC127 5 A, 250 Vac In live and neutral Output *NLP65-76xx version only Total regulation: Main output 2.0% (line and load) Auxiliary outputs 5.0% Rise time: At turn-on 1.0 s, max Transient response: Main output 5.0% or 250 mV 25% step max. dev., 1ms max. at 0.1 A/s recovery to 1% Temperature coefcient: 0.02%/C Overvoltage protection: Main outputs 125%, 10% Short circuit protection: Cyclic operation Continuous Minimum output current: Single and multiple (See Note 6)NLP65 Series Data Sheet All specications are typical at nominal input, full load at 25 C unless otherwise stated. (11, 12) EMC Charateristics Conducted emissions: EN55022, FCC part 15 Level B ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-5, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-3, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2 General Specifications Hold-up time: 120 Vac, 60 Hz 16 ms 65 W 230 Vac, 50 Hz 78 ms 65 W Efciency: 120 Vac, 65 W 72% typical Isolation voltage: Input/output 3000 Vac Input/chassis 1500 Vac Switching frequency: Fixed 100 kHz, 5 kHz Approvals and standards: EN60950-1, IEC60950-1 (see Notes 9, 13) Weight: 283 g (10 oz) MTBF demonstrated: MIL-HDBK-217F 150,000 hours min Environmental Specifications Thermal performance: Operating (See derating curve) 0 C to +70 C (See notes 1, 3, 10) Non-operating -40 C to +85 C 50 C - 70 C ambient, convection cooled Derate to 50% load 0 C to 50 C, ambient, convection cooled 65 W 0 C to 50 C, ambient 20CFM forced air (See Note 10) 75 W Peak (0 C to 50 C, 60 s) See table Relative humidity: Non-condensing 5 to 95% RH Altitude: Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 5): 5-500 Hz 2.4 G rms peak Shock per MIL-STD-810E 516.4 Part IV