Open Frame 3.00 X4.00 Universal Input AC/DC Converter (1) Dual Output 5V/12V 20W Model UPS20-5002 Voltage Current Regulation (4) Ripple & OUTPUT Noise Rated Tolerance Min Rated Peak (3) Load Line Main +5 V DC +/-2.00% 0.2A 1.6A 2.0A 50mV 2.00% 0.50% +12 V DC +/-5.00% 0.2A 1.0A 2.0A 120mV 5.00% 1.00% INPUT Min Nom Max 90VAC 260VAC Voltage AC Universal AC Frequency 47Hz 63Hz Inrush Current At Min 115 VAC Max 230 VAC 20A 40A Switching Frequency 40K Hz. Hold-up Time Measured at 115VAC and rated Load 20mS Fusing 2A, Slow-blow 115/230 VAC Non-User Serviceable GENERAL SPECIFICATIONS Efficiency 68% Min. Full Load 120 VAC Overvoltage Protection +5V exceeds 5.8V Causes shutdown, automatic recovery Overload Protection All outputs protected against short circuit conditions, automatic recovery. Environmental o Temperature coefficient 0.02%/ C, All outputs o o Operational 0 to 50 C at rated output power. Derates linearly to 50% power at 70 C. Temperature Range o o Storage -55 C to 85 C Safety, Regulatory & EMI UL60950 Agency Approvals CSA C22.2 N0.60950 TUV EN60950 High Pot 3600 VAC input to output for 1 sec. EMI Meets F.C.C part 15 class B conductedand CISPR 22 conducted Autec Power Systems Tel: (805)522-0888 www.autec.com 685 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Model UPS20-5002 PIN ASSIGNMENTS UPS20-5002 WIDTH LENGTH HEIGHT CN1 CN2 CONNECTOR inch 3.00 4.00 1.09 AC INPUT DC OUTPUT OUTLINE mm 76.2 101.6 27.7 PIN 1 LINE +5 V PIN 2 N/C +5 V inch 2.56 3.54 N/A MOUNTING PIN 3 NEUTRAL COM mm 65.0 89.9 N/A PIN 4 COM PIN 5 +12 V SHIPPING SPECIFICATIONS PIN 6 +12 V MODEL UNITS PER CARTON CARTON WEIGHT MOLEX (or equiv) 09-65-2038 09-65-2068 UPS20-5002 64.0 13.5 Kgs 29.8 Lbs Mating Connector 09-50-1031 09-50-1061 NOTES: 1. The power supply may be capable of more than the specified continuous and/or peak ratings, depending on the application. Consult factory Sales Engineer for feasibility. 2. Minimum load specified assures output voltage stability for all specified line voltage conditions. Full compliance to the total regulation specification may require additional loading (not to exceed 25% of rated output current). Operation at no load will not damage the power supply. 3. Each output can provide its full rated output current, provided total wattage does not exceed nominal (continuous) rating. 4. Total regulation includes the combined effects of: a) initial set point of main output of 1% max b) line regulation for any input voltage change between 90 & 264 VAC c) load regulation for a MIN. 100% of rated continuous load change: assumes that the total continuous power rating of the supply is not exceeded. See Note3 . Performance during peak loading conditions is not included in the figure. 5.Specifications are subject to change without notice. AUTEC cannot be held liable for errors or omissions or the consequences thereof. 6.Units that meet CISPR also comply with FCC level B. Autec Power Systems Tel: (805)522-0888 www.autec.com 685 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 UPS20-5002