TZN/TZ SeriesTZN/TZ Series Dual PID Control Temperature Controller Features Dual PID auto tuning function: High-speed response of PID control to reach to the desired value fast, low-speed of response of PID control to minimize the overshoot even though response is a little bit slow. High display accuracy: 0.3% (by F.S. value of each input) 2-step auto tuning control function Multi-input function (13 kinds of multi-input selection function): Temperature sensor, voltage and current selection function. Various sub output function: Includes in LBA, SBA, 7 kinds of alarm output and 4 kinds of alarm option function, PV transmission output (DC4-20mA), RS485 communication output Display the decimal point for analog input Please read Safety Considerations in the instruction manual before using. Comprehensive Device Management Program (DAQMaster) DAQMaster is comprehensive device management program for convenient management of parameters and multiple device data monitoring. Visit our website (www.autonics.com) to download user manual and comprehensive device management program. < Computer specification for using software > < DAQMaster screen > Item Minimum requirements System IBM PC compatible computer with Intel Pentium or above Operating system Microsoft Windows 98/NT/XP/Vista/7/8/10 Memory 256MB or more Hard disk More than 1GB of free hard disk space VGA 1024768 or higher resolution display Others RS-232 serial port (9-pin), USB port Ordering Information TZ 4 M 1 4 R R Relay output Control output S SSR drive output C Current output(DC4-20mA) Power supply 4 100-240VAC 50/60Hz TZ4SP/TZN4S 1 Event 1 output 1 Event 1 output TZ4ST 2 Event 1 + Event 2 output R Event 1 + PV transmission output(DC4-20mA) Option output 1 Event 1 output 2 Event 1 + Event 2 output Others R Event 1 + PV transmission output(DC4-20mA) A Event 1 + Event 2 + PV transmission output(DC4-20mA) T Event 1 + RS485 communication output B Event 1 + Event 2 + RS485 communication output TZN4 S DIN W48H48mm (terminal block type) 1 TZ4 SP DIN W48H48mm (plug type) Size ST DIN W48H48mm (terminal block type) M DIN W72H72mm TZ4/TZN4 W DIN W96H48mm H DIN W48H96mm L DIN W96H96mm Digit 4 9999 (4-digit) Item TZ Temperature Controller TZN Temperature Controller The unit cannot be configured with any random combination from the above ordering information. Please refer to Specifications for possible configurations. 1: 11-pin sockets (PG-11, PS-11(N)) are sold separately. J-140Dual PID Control Specifications TZ4SP TZ4M TZ4W TZ4H TZ4L SENSORS Series TZ4ST TZN4S TZN4M TZN4W TZN4H TZN4L Power supply 100-240VAC 50/60Hz Allowable voltage range 90 to 110% of rated power voltage CONTROLLERS Power consumption Max. 5VA (100-240VAC 50/60Hz) Max. 6VA (100-240VAC 50/60Hz) Display method 7-segment LED (PV: red, SV: green) MOTION DEVICES TZ4SP: TZ4M: TZ4H: 4.87.8mm 9.814.2mm 3.87.6mm PV 9.814.2mm TZN4S: TZN4M: TZN4H: SOFTWARE 7.811.0mm 8.013.0mm 7.811.0mm 4.87.8mm 8.010.0mm TZ4SP: TZ4M: TZ4H: 4.87.8mm 8.010.0mm 3.87.6mm SV 8.010.0mm TZN4S: TZN4M: TZN4H: 5.88.0mm 5.09.0mm 5.88.0mm RTD DPt100, JPt100, 3-wire (allowed resistance: max. 5 per line) Input TC K(CA), J(IC), R(PR), E(CR), T(CC), S(PR), N(NN), W(TT) (allowed resistance: max. 100 per line) type Analog 1-5VDC , 0-10VDC , DC4-20mA (J) Display accuracy F.S. 0.3% or 3 , greater value Temperature Controllers Relay 250VAC 3A, 30VDC 3A, 1c Control SSR Max. 12VDC 3V 30mA (K) output SSRs Current DC4-20mA (load resistance max. 600) EVENT1 250VAC 1A 1a (L) EVENT2 - 250VAC 1A 1a Option Power Controllers output PV transmission- DC4-20mA (load resistance max. 600) Communication- RS485 communication (M) Control method ON/OFF, P, PI, PD, PIDF, PIDS control Counters Alarm output hysteresis 1 to 100 (0.1 to 100.0) variable Proportional band (P) 0.0 to 100.0% (N) Timers Integral time (I) 0 to 3,600 sec Derivative time (D) 0 to 3,600 sec (O) Control period (T) 1 to 120 sec Digital Panel Meters Sampling period 0.5 sec LBA setting 1 to 999 sec (P) Ramp setting Ramp Up, Ramp Down: 1 to 99 min each Indicators Dielectric strength 2,000VAC 50/60Hz for 1 min (between input and power terminals) Mechanical 0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours (Q) Vibration Converters Electrical 0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min Mechanical: min. 10,000,000 operations, Control output (R) Electrical: min. 100,000 operations (250VAC 3A resistance load) Relay Digital Display Units life cycle Mechanical: min. 20,000,000 operations, Option output Electrical: min. 500,000 operations (250VAC 1A resistance load) (S) Insulation resistance Over 100M (at 500VDC megger) Sensor Controllers Noise immunity Square shaped noise by noise simulator (pulse width 1) 2kV R-phase, S-phase (T) Memory retention Approx. 10 years (non-volatile semiconductor memory type) Switching Mode Power Ambient temp. -10 to 50, storage: -20 to 60 Environ- Supplies ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Approval (U) Recorders TZ4SP: TZ4M: TZ4W: TZ4H: TZ4L: approx. 205g approx. 360g approx. 365g approx. 365g approx. 474g (V) (approx. 144g) Approx. 218g (approx. 228g) (approx. 246g) (approx. 246g) (approx. 304g) 1 Weight HMIs TZN4S: (approx. 162g) TZN4M: TZN4W: TZN4H: TZN4L: approx. 226g approx.355g approx. 351g approx. 351g approx. 474g (approx. 164g) (approx. 246g) (approx. 232g) (approx. 232g) (approx. 303g) (W) Panel PC 1: The weight includes packaging. The weight in parenthesis is for unit only. Environment resistance is rated at no freezing or condensation. (X) Field Network Devices J-141 Character size (WH)