Auto And Manual Ranging, Automatic Power - Off, Hold Function, Peak Hold Function For Ac Measurements, Display Zeroing Function In Dca Measurements, Low Battery Indicator
|
|
(0 , 75 % + 2 digits)
|
0 , 1 To 400/600 V
|
(1 , 2 % + 5 digits)
|
40hz To 450hz
|
0 , 1 To 400/600 A
|
(2 % + 5 digits)
|
0 , 1 To 400/600 A
|
(2 % + 5 digits)
|
40hz To 450hz
|
1 To 4000 Ohms
|
± (1 % + 5 digits)
|
1 To 4k/20 KHz
|
(0 , 5 % + 5 digits)
|
5 A /1 V for 4 KHz , 5 A /5 V for 20 KHz
|
Lcd 3,75 Digit (3999)
|
1 b A ttery 9 V 6f22
|
En61010 600V Cat Iii
|
Battery, Soft Cover, Test Leads
|
|
Acoustic Signal For R<40Ω
|
|
|
Frequency, Ac Voltage, Dc Voltage, Ac Current, Dc Current, Resistance
|
Ac/Dc Digital Clamp Meter
|
|
|
|