MPU200/MDU200 Series Data Sheet Features RoHS lead free solder and lead solder exempted products are available Power Factor Correction (PFC) meets EN61000-3-2 Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad model outputs V1 and V2 Remote sense on quad model outputs V1 and V2 Current share and N+1 redundancy (standard on all models) Overtemperature, overload, and overvoltage protection Available with SAE mountings MDU200 models have 48 VDC input Description The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200 watts of continuous output power is provided with single or multiple output units suited for distributed power or central power applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry. Power-One s dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch. The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 VDC input. AC Input, Single-Output Model Selection 200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1) OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 2) CURRENT (NOTE 2) REGULATION REGULATION %p-p (NOTE 3) ACCURACY MPU200-1012G 12V 11.6V to 16V 17.0A 19.0A 0.1% 1% 1% 11.97V to 12.03V MPU200-1024G 24V 22.8V to 29.2V 8.35A 9.4A 0.1% 1% 1% 23.95V to 24.05V MPU200-1048G 48V 45V to 56V 4.2A 4.7A 0.1% 1% 1% 47.9V to 48.1V AC Input, Multiple-Output Model Selection 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 2) REGULATION REGULATION %Pk-Pk (NOTE 3) ACCURACY +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V +3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V MPU200-4530 12V 10.8V to 13.2V 8A (Note 5) 0.4% 10% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 4A (Note 5) 0.4% 10% 1% 11.60V to 12.40V NOTES: 1) This product is not rated for convection applications. 2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be applied from the input side of the power supply blowing towards the output. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Total current for V1 and V2 is not to exceed 35A. 5) Total power on V3 and V4 is not to exceed 100W. Model numbers highlighted in yellow or shaded are not recommended for new designs. Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER Metric Mounting Add M as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts. Consult factory for availability. Isolation Diode Offered on single-output models. Add D to the part number suffix if an isolation diode is needed. Consult factory for availability. RoHS lead solder exemption No RoHS suffix character required. RoHS compliant for all 6 substances Add G as the last character of the part number. MCD10010 Rev. 1.1, 27-Jan-10 Page 1 of 6 www.power-one.comMPU200/MDU200 Series Data Sheet DC Input, Single Output Model Selection 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 2) CURRENT (NOTE 2) REGULATION REGULATION %Pk-Pk (NOTE 3) ACCURACY MDU200-1012G 12V 11.6V to 16V 17.0A 19.0A 0.1% 1% 1% 11.97V to 12.03V MDU200-1024G 24V 22.8V to 29.2V 8.35A 9.4A 0.1% 1% 1% 23.95V to 24.05V (NOTE 4) MDU200-1048G 48V 45V to 56V 4.2A 4.7A 0.1% 1% 1% 47.9V to 48.1V Isolation Diode Option - Offered on single-output models. Add D at the end of the part number if an isolation diode is needed. Model numbers highlighted in yellow or shaded are not recommended for new designs. MPU200 Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 200 watts 15 ms Input Current 85 VAC at full rated load. 4.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. 100 120 Switching frequency of secondary transformer. 65 90 kHz Switching frequency of Power Factor Correction circuit. 60 MDU200 Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC Hold-up Time At 200 watts, over DC input range. 15 ms Input Current 36 VDC at full rated load. 8.35 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Consult factory. Operating Frequency Switching frequency of main output transformer. 100 kHz Switching frequency of secondary transformer. 70 NOTES:1) This product is not rated for convection applications. 2) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended that the airflow be applied from the input side of the power supply blowing towards the output. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Derating is required on output voltages above 27VDC. Consult factory. MCD10010 Rev. 1.1, 27-Jan-10 Page 2 of 6 www.power-one.com