NOW PART OF C-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part Compact Circuit Breaker with High Amperage and Voltage Capabilities Compact yet robust, the C-Series hydraulic-magnetic circuit breaker is designed for high amperage and voltage applications. C-Series breakers are available as a one to six pole configuration and are rated up to 100 amps, 480VAC/80VDC or 240VAC/125VDC for UL 489 configurations. Parallel pole options offer ratings from 100-250 amps. The C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. 1-6 250 480 125 Poles Amps Max VAC Max VDC Max Typical Applications Marine Renewable Energy Military Datacom/Telecom Generators & Welders www.carlingtech.com 860.793.9281 sales carlingtech.comTech Spec Mechanical Electrical Endurance 10,000 ON-OFF operations 6 Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz per minute with rated current & (see Table A.) UL489: AC,240 VAC. voltage. (See Table D),50/60 Hz, 125 VDC Trip Free All circuit breakers will trip on Current Ratings Standard current coils: 0.100, overload, even when actuator is 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, forcibly held in the ON position. 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 Trip Indication The operating actuator moves amps. Other ratings available, positively to the OFF position see ordering scheme. when an overload causes the breaker to trip. With mid-trip, Standard Voltage Coils DC - 6V, 12V AC - 120V other ratings handle moves to the mid position available, see ordering scheme. on electrical trip of the circuit Auxiliary Switch Rating SPDT 10.1 amps-250VAC, DC breaker. With mid trip handle with Aux.Switch 1.0A, 65 VDC. 0.5A, alarm switch, handle moves to 80VDC,1/4 HP, 125VAC,VDE & TUV1.0 the mid position and the alarm 125 VAC. switch actuates when the circuit breaker is electrically tripped. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Physical Dielectric Strength UL, CSA: 1960 V 50/60 Hz for oneminute between all Number of Poles 1-6 poles 50A 1-4 poles electrically isolated terminals. 51-70A 1-2 poles 71-100A. UL489 C-Series Circuit Breakers comply Handle: 1 pole 100A, 2 pole 50A with the 8mm spacing and 3750V Rocker: 1 pole 100A 50/60 Hz dielectric requirements Internal Circuit Config. Series (with or without auxiliary from hazardous voltage to switch, mid trip & mid trip with operator accessible surfaces, alarm switch) Shunt & Relay with between adjacent poles and current or voltage trip coils, Dual from main circuits to auxiliary Coil, Switch Only (with or without circuits per Publications EN 60950 aux. switch). UL489: Series (with or and VDE 0805. without auxiliary switch, mid-trip Resistance, Impedance Values from Line to Load Terminal & midtrip with alarm switch). -based on Series Trip Circuit Weight Approx.112 grams/pole ( 3.95 oz). Breaker. Standard Colors Housing: Black RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) 1000 Environmental CURRENT TOLERANCE (AMPS) (%) Designed and tested in accordance with requirements of 100 specification MIL-PRF-55629 & MIL-STD-202 as follows: 0.10 - 5.0 15 5.1 - 20.0 25 Shock Withstands 100Gs,6mssawtooth 10 while carrying rated current 20.1 - 50.0 35 pernMethod 213, Test Condition I. O Instantaneous and ultrashort curves H 1 M tested 90% of rated current. S 0.1 Vibration Withstands 0.060 excursion from 60 Hz 1/2 Cycle Inrush Pulse Tolerance 10-55 Hz & 10 Gs 55-500 Hz, I r Time Delay Curves rated current per Method 204C, 42, 44 & 46 0.01 (50 Amps Max.) Test Cond. A. Instantaneous & 25x Time Delay Curves ultrashort curves tested 90% of 22, 24 (100 Amps Max.) 12x 26 (70 Amps Max.) rated current. 0.001 0.01 0.1 1 10 100 t Moisture Resistance Method 106D, i.e., ten 24-hour AMPERE RATING 8.33 16.67 4.165 cycles +25C to +65C, CURRENT TOLERANCE 80-98% RH.. Pulse Tolerance Curves (AMPS) (%) 60 Hz 1/2 Cycle 0.100 - 5.0 15% Inrush Pulse Tolerance 5.1 - 20.0 25% I 50 Hz 1/2 Cycle r Salt Spray Method 101, Condition A (90-95% Time Delay Curves20.1 - 100 35% Inrush Pulse Tolerance I r 42, 44 & 46 Time Delay Curves RH 5% NaCl Solution, 96 hrs). (50 Amps Max.) 25x FIGURE 1 22x 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 (100 Amps Max.) Time Delay Curves Thermal Shock RH 5% NaCl Solution, 96 hrs). 12x 26 (70 Amps Max.) 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) Thermal Shock Method 107D, t t Condition A (five cycles -55C 8.33 16.67 4.165 10.0 20.0 5.0 to +25C to +85C to +25C). Time in Milliseconds Operating Temperature -40 C to +85 C 50 Hz 1/2 Cycle Inrush Pulse Tolerance I r Time Delay Curves 22x 42, 44 & 46 2. *Manufacturer reserves the right to change product specification without prior notice.(50 Amps Max.) Time Delay Curves 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) t 10.0 20.0 5.0 Time in Milliseconds Multiple of Multiple of Rated Current Rated Current Multiple of Multiple of Rated Current Rated Current