D-SD-Series eries
CIRCUIT BREAKER
Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical
Din Rail, allowing rapid and simple mounting and removal of the breaker. It features recessed, wire-ready,
touch-proof, shock-resistant terminals, suitable for automatic screwdriver assembly, as well as Dead Front
construction characteristics.
Available with a Visi-Rocker two-color actuator, which can be specified to indicate either the ON or the
TRIPPED/OFF mode, or solid color rocker or handle type actuators. All actuator types fit in the same industry
standard panel cutouts.
Product Highlights: Typical Applications:
0.02 - 50 Amps Industrial Controls
480 VAC or 65 VDC Renewable Energy
1-4 poles (Handle)
1-3 poles (Rocker)
Choice of Time Delays
DIN rail mounting
Precise temperature independent operation
Wiping contacts mechanical linkage with two-step
Finger safe terminals
Common trip linkage between poles
ensures that an overload in one pole will trip all
adjacent poles
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com www.carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231| D-Series Circuit Breaker - General Specifications
2
Mechanical
Electrical
Maximum Voltage AC, 480 wye/277 VAC Endurance 10,000 ON-OFF operations @ 6
(See Table A), 50/60 Hz, 65VDC per minute; with rated Current
Standard Current Coils 0.100, 0.250, 0.500, 0.750, 1.00, and Voltage.
2.50, 5.00, 7.50, 10.0, 15.0, 20.0, Trip Free All D-Series Circuit Breakers will
25.0, 30.0, 35.0, 40.0 & 50.0. trip on overload, even when
Other ratings available - actuator is forcibly held in the ON
consult factory. position.
Standard Voltage Coils DC - 6V, 12V; AC - 120V, other Trip Indication The operating actuator moves
ratings available, see ordering positively to the OFF position
scheme. when an overload causes the
Insulation Resistance Minimum of 100 Megohms at 500 breaker to trip.
VDC.
Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one
Physical
minute between all electrically
Number of Poles Rocker Type: 1-3; Handle Type:
isolated terminals. D-Series circuit
1-4
breakers comply with the 8mm
Internal Circuit Config. Switch Only and Series Trip with
spacing and 3750V 50/60 Hz
current or voltage trip coils.
dielectric requirements from
Weight Approximately 128 grams/pole
hazardous voltage to operator
(Approximately 4.57 ounces/pole)
accessible surfaces and between
Standard Colors Housing - Black; Actuator - See
adjacent poles per Publications
Ordering Scheme.
EN 60950 and VDE 0805.
Mounting Mounts on a standard 35mm
Resistance, Impedance Values from Line to Load Terminal
Symmetrical DIN Rail (35 x 7.5 or
- based on Series Trip Circuit
35 x 15mm per DIN EN5002).
Breaker
RESISTANCE PER POLE VALUES Environmental
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
CURRENT TOLERANCE
(AMPS) (%)
Shock Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
0.10 - 5.0 15
Method 213, Test Condition I.
5.1 - 20.0 25
Instantaneous and ultra-short
20.1 - 50.0 35
curves tested @ 90% of rated
current.
Vibration Withstands 0.060 excursion from
10-55 Hz, and 10 Gs 55-500 Hz,
at rated current per Method 204C,
Test Condition A. Instantaneous
and ultra-short curves tested at
90% of rated current.
Moisture Resistance Method 106D, i.e., ten 24-hour
Pulse Tolerance Curves cycles @ + 25C to +65C, 80-
98% RH.
Salt Spray Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock Method 107D, Condition A (Five
cycles @ -55C to +25C to +85C
to +25C).
Operating Temperature -40 C to +85 C
*Manufacturer reserves the right to change product specification without prior notice.