NOW PART OF E-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE request sample, configure part High Current and Voltage Breaker Qualified Supplementary Protector The E-Series hydraulic-magnetic circuit breaker is designed for higher current and voltage applications and qualified, as per agency approval, for branch circuit protection or as a supplementary protector. E-Series breakers are available as a one to six pole configuration and are rated up to 125 amps and 600VAC or 125VDC, with a max IC of 10,000 amps. 1-6 1-100 600 125 Poles Amps VAC Max VDC Max Typical Applications Industrial Automation High Voltage/Current Applications Renewable Energy Generators Military www.carlingtech.com 860.793.9281 sales carlingtech.comE-Series Circuit Breaker General Specifications Tech Specs Mechanical Electrical Endurance 10,000 ON-OFF operations 6 Maximum Voltage 600VAC 50/60 Hz, 125VDC (See per minute with rated current & Table A) voltage. Current Ratings Standard current coils: 0.100, Trip Free All E-Series circuit breakers will 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, trip on overload, even when 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, Handle is forcibly held in the ON 70.0 & 100 Amp. position. Auxiliary Switch Rating SPDT 10.1A 250VAC, 1.0A 65VDC Trip Indication The operating Handle moves 0.5A 80VDC, 0.1A 125VAC (with positively to the OFF position gold contacts). when an overload causes the Insulation Resistance Minimum of 100 Megohms at 500 breaker to trip. VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one Physical minute between all electrically isolated terminals. E-Series Circuit Number of Poles 1-6 Breakers comply with the 8mm spacing and 3750V 50/60 Hz Mounting A 3 minimum spacing must dielectric requirements from be provided between the hazardous voltage to operator circuit breaker arc venting area accessible surfaces, between on back connected E-Series adjacent poles and from main circuit breakers and grounded circuits to auxiliary circuits per obstructions. E-Series circuit Publications EN 60950 and VDE breakers must be mounted on a 0805. vertical surface. Resistance, Impedance Values from Line to Load Terminal Connectors, Box Type Front connected E-Series circuit - based on Series Trip Circuit breakers are supplied with box Breaker type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Internal Circuit Series and Switch Only, (with or CURRENT TOLERANCE Configuration Configuration without auxiliary (AMPS) (%) switch). Shunt with current coils. 0.10 - 5.0 15 Weight Approximately 252 grams/pole 5.1 - 20.0 25 (Approximately 9 ounces/pole) 20.1 - 50.0 35 Standard Colors Housing-Black Actuator - See Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition I. Vibration Withstands 0.060 excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at Pulse Tolerance Curves rated current per Method 204C, 60 Hz 1/2 Cycle Inrush Pulse Tolerance Test Condition A. I r 50 Hz 1/2 Cycle Time Delay Curves Inrush Pulse Tolerance 62, 64 & 66 I r Moisture Resistance Method 106D, i.e., ten 24-hour cycles Time Delay Curves (100 Amps Max.) 25x 22x 42, 44 & 46 + 25C to +65C, 80-98% RH. (50 Amps Max.) Time Delay Curves 22, 24 & 26 (100 Amps Max.) Time Delay Curves 10x 12x 22, 24, 26 (70 Amps Max) Salt Spray Method 101, Condition A (90-95% t RH 5% NaCl Solution, 96 hrs). t 10.0 20.0 5.0 8.33 16.67 4.165 Time in Thermal Shock Method 107D, Condition A (Five Time in Milliseconds Milliseconds cycles -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C 2. *Manufacturer reserves the right to change product specification without prior notice. Multiple of Rated Current Multiple of Rated Current