E-SE-Series eries CIRCUIT BREAKER The E-Series hydraulic-magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Product Highlights: Typical Applications: UL listed and CSA certified High Voltage/High Current Applications Certified for circuit branch protection Renewable Energy Recognized as a supplementary protector and as a manual motor controller Military Optional power selector device Industrial Controls Generators Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales carlingtech.com www.carlingtech.com Application Support: team2 carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 2 E-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Endurance 10,000 ON-OFF operations 6 Table A) per minute with rated Current and Current Ratings Standard current coils: 0.100, Voltage. 0.250, 0.500, 1.00, 2.50, 5.00, Trip Free All E-Series Circuit Breakers will 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, trip on overload, even when 50.0, 60.0, 70.0 & 100 Amp. Handle is forcibly held in the ON Auxiliary Switch Rating SPDT 10.1A 250VAC, 1.0A position. 65VDC 0.5A 80VDC, 0.1A 125VAC Trip Indication The operating Handle moves (with gold contacts). positively to the OFF position Insulation Resistance Minimum of 100 Megohms at 500 when an overload causes the VDC. breaker to trip. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one Physical minute between all electrically isolated terminals. E-Series Circuit Number of Poles 1 - 6 Breakers comply with the 8mm Mounting A 3 minimum spacing must be spacing and 3750V 50/60 Hz provided between the circuit dielectric requirements from breaker arc venting area on back hazardous voltage to operator connected E-Series circuit accessible surfaces, between breakers and grounded adjacent poles and from main obstructions. E-Series circuit circuits to auxiliary circuits per breakers must be mounted on a Publications EN 60950 and VDE vertical surface. 0805. Connectors, Box Type Front connected E-Series circuit Resistance, Impedance Values from Line to Load Terminal breakers are supplied with box - based on Series Trip Circuit type pressure connectors that Breaker. accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Internal Circuit Series and Switch Only, (with or CURRENT TOLERANCE Configuration without auxiliary switch). Shunt (AMPS) (%) with current coils. 0.10 - 5.0 15 Weight Approximately 252 grams/pole 5.1 - 20.0 25 (Approximately 9 ounces/pole) Standard Colors Housing-Black Actuator - See 20.1 - 50.0 35 Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Pulse Tolerance Curves Method 213, Test Condition I. Vibration Withstands 0.060 excursion from Time Delay Curves 10-55 Hz, and 10 Gs 55-500 Hz, at 62, 64 & 66 (100 Amps Max.) rated current per Method 204C, Time Delay Curves Test Condition A. 22, 24 & 26 (100 Amps Max.) Moisture Resistance Method 106D, i.e., ten 24-hour cycles + 25C to +65C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C *Manufacturer reserves the right to change product specification without prior notice. Email: sales carlingtech.com Application Support: team2 carlingtech.com Phone: (860) 7939281 Fax: (860) 7939231 www.carlingtech.com