CERTUS Configurable Safety Module Reduces the number of components (less footprint and wiring) Faster electrical cabinet construction Flexible, intuitive and quick logical configuration software Easy to set up tamper-proof safety systems Simplifies machine maintenance through the Configuration Memory Card, which can be used to transfer the configuration program to a new CERTUS in just a few simple steps Ideal for machine designers Certified to the highest safety levels: SIL +, SILCL 3, PLe, Cat.4 Up to 128 inputs and 16 OSSD pairs Up to 14 expansion units in addition to the CMM Master, excluding relay modules Compact design: single module dimensions (W x H x D) 108 x 22.5 x 114.5 Product Description Ordering Key C MM Model CERTUS is the new Thanks to the new CERTUS Carlo Gavazzi modular modular structure, it Type configurable safety system. is possible to adapt This new safety device its I/O configuration is capable of monitoring and functionality to the several safety photocells, demands of many different emergency stops, applications making safety mats, magnetic CERTUS a highly versatile or mechanical switches, and flexible safety system. twohand controls etc. Type Selection Diagnostic and data CMM Programmable master unit communication family Expansion units for C 8I2O I/O expansion unit C 8I - C 16I Input expansion unit C PDP, C DNET, C CAN, Diagnostics and Data C EIP, C ECAT, C PFNET, Communication C 12I - C 8TO I/O expansion unit C OMMS C 2OSSD - C 4OSSD Output expansion unit Speed monitoring family Expansion units to monitor C 2R - C 4R Guided contact relay output C PSS, C ES1T, C ES2T, speed (PLe): zero, max and expansion unit. CBT Bus transfer expansion units C ES1H, C ES2H, C ES1S, range, plus motion direction, C ES2S rotation/translation General Data Over voltage category II Max. number of inputs 128 Max. number of outputs 16 Digital Inputs PNP active high, according to EN 61131-2 Max. number of expansion units 14 Digital otputs PNP active high Max. number of expansion 400mA 24VDC units of the same type 4 Response time Rated voltage 24VDC 20% Supply from class II (LVLE) Master 10,6 to 12,6ms + TInput filter 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/03/2015CERTUS Configurable Safety Module General Data CMM + 1 Expansion unit 11,8 to 26,5 + TInput filter Max. length of connections 100m CMM + 2 Expansion units 12,8 to 28,7 + TInput filter Operating temperature -10 to 55C CMM + 3 Expansion units 13,9 to 30,8 + TInput filter Max. sorrounding CMM + 4 Expansion units 15 to 33 + TInput filter air temperature 55C CMM + 5 Expansion units 16 to 35 + TInput filter Storage temperature +20 to 85C CMM + 6 Expansion units 17 to 37,3 + TInput filter Relative humidity 10% to 95% CMM + 7 Expansion units 18,2 to 39,5 + TInput filter Description Electronic housing max 24 CMM + 8 Expansion units 19,3 to 41,7 + TInput filter pole, with locking latch CMM + 9 Expansion units 20,4 to 43,8 + TInput filter mounting. CMM + 10 Expansion units 21,5 to 46 + TInput filter Enclosure material Polyamide CMM + 11 Expansion units 22,5 to 48,1 + TInput filter Enclosure protection class IP20 CMM + 12 Expansion units 23,6 to 50,3 + TInput filter Terminal blocks protection class IP2X CMM + 13 Expansion units 24,7 to 52,5 + TInput filter Fastening Quick coupling to DIN rail CMM + 14 Expansion units 25,8 to 56,4 + TInput filter according to EN60715 Connection cable C.G. proprietary 5-pole bus Dimensions (H x W x D) 108 x 22.5 x 114.5 2 Connection cable cross section 0,5 to 2,5 mm / AWG 12 to 30 (solid/stranded) Main Unit and Expansion Units Features CMM stand alone main unit: - 4 safety relays - 4 NO + 2 NC connectable to 2 independent - 8 safety inputs, 2 OSSD pairs - 400mA output current - OSSD pairs. with separate EDM and Start/Restart, 4 test outputs - 2/4 safety relays with 6A 250VAC guided contacts. and 2 programmable status outputs - 1/2 NC contacts for External Device Monitoring (EDM). - Configurable via PC through USB interface - CMC (CERTUS Configuration Memory Card) slot for C DDC Data and Diagnostic Communication expansion program storage (optional feature) units for connection to the most common industrial Fieldbus system: C 8I 2O expansion unit: C PDP - Profibus DP - 8 safety inputs, 2 OSSD pairs - 400mA output current - with C DNET - DeviceNet separate EDM and Start/Restart, 4 test outputs and 2 C CAN - CANopen programmable status outputs (same as CMM but no CPU). C EIP - Ether net IP C ECAT - EtherCAT C 8I and C 16I expansion units: C PFNET - PROFINET - 8 and 16 safety inputs, 4 test outputs. C OMMS - Universal Serial Bus C 12I 8TO expansion unit: CBT Bus transfer expansion unit, up to 50m length per - 2 safety inpus, 8 test otputs - can control up to 4-wire connection. Maximum of 6 connections per system safety mats. Speed Monitoring expansion units to monitor (PLe): C 2OSSD and C 4OSSD expansion units: Zero speed - 2 and 4 OSSD pairs - 400mA output current - with separate Max speed EDM and Start/Restart, 2/4 programmable status outputs. Speed range C EIP - Ether net IP Motion direction rotation / translation. C 2R and C 4R relay expansion units: - 2 safety relays - 2 NO + 1 NC connectable to 1 OSSD pair. Characteristic of the Output Circuit Excitation voltage 17...31 VDC Maximum switchable Minimum switchable voltage 10VDC voltage (AC) 400VAC Minimum switchable curent 20 mA Maximum switchable current 6A Maximum switchable Response time 12ms 6 voltage (DC) 250VDC Mechanical life of contacts > 20 x 10 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/03/2015