Product Information

CPTASOFT-KIT

CPTASOFT-KIT electronic component of Carlo Gavazzi

Datasheet
PROGRAMMING SOFTWARE FOR CPT ADVNCD + PROGRAMMING CABLE

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 399.8238 ea
Line Total: USD 399.82

1 - Global Stock
Ships to you between
Thu. 09 May to Wed. 15 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - WHS 1


Ships to you between Thu. 09 May to Wed. 15 May

MOQ : 1
Multiples : 1

Stock Image

CPTASOFT-KIT
Carlo Gavazzi

1 : USD 274.9556
3 : USD 263.4581
5 : USD 256.3575
10 : USD 246.435
25 : USD 240.2662

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 2

A82-20500 electronic component of Carlo Gavazzi A82-20500

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 3

AD2000 electronic component of Carlo Gavazzi AD2000

Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1

AQ1038 electronic component of Carlo Gavazzi AQ1038

Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1

AD1040 electronic component of Carlo Gavazzi AD1040

Power Analysers WM4-96 BASE REV.0
Stock : 1

AO1032 electronic component of Carlo Gavazzi AO1032

Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1

5100532 electronic component of Carlo Gavazzi 5100532

Panel Meters and Controllers Panel Meter Modular
Stock : 1

ACR1252U electronic component of Carlo Gavazzi ACR1252U

USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0

AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC

LATCH UNIT 100-25A
Stock : 1

APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01

Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1

Image Description
CYG2030 electronic component of IXYS CYG2030

Interface Modules Cybergate DAA Module
Stock : 1

MPCI-IBD192 electronic component of Ibase MPCI-IBD192

Interface Modules mPCIe,2*GLAN card,IBLD170 RJ45 w/Cable kit,2*Screws (RoHS)
Stock : 1

VAB-600-D electronic component of VIA VAB-600-D

Expansion board; LVDS x2,pin header; Works with: VAB-600
Stock : 1

MOTG-AC2 electronic component of 4D Systems MOTG-AC2

Interface Modules 2-slot MOTG for Gen4 Diablo
Stock : 1

WIZ145SR electronic component of Wiznet WIZ145SR

Interface Modules PIN HDR TYPE SERIAL-ENET MOD
Stock : 131

RS485-RS232 electronic component of Littelfuse RS485-RS232

Interface Modules RS-485:RS-232CONV.W/ CABLE&
Stock : 1

88980114 electronic component of Crouzet 88980114

Interface Modules Memory Interface for Controllers, Compatible With em4 And Millenium EVO Families
Stock : 1

PCE-3B06-00A1E electronic component of Advantech PCE-3B06-00A1E

Interface Modules 6-Slot PICMG1.3 BP,1 CPU Card, 1 PCIe x16, 4 PCIe x1,RoHS for IPC-6806S/IPC-3026
Stock : 0

PCA-6106P3-0D2E electronic component of Advantech PCA-6106P3-0D2E

Interface Modules 6-Slot Backplane (2 ISA, 2 PCI, 1 PICMG/PCI, 1 PICMG) Rev C. for IPC-6606, IPC-6006 and IPC-6806
Stock : 5

B-XC-232 electronic component of Advantech B-XC-232

Interface Modules B-XC-232-5
Stock : 1

CERTUS Configurable Safety Module Reduces the number of components (less footprint and wiring) Faster electrical cabinet construction Flexible, intuitive and quick logical configuration software Easy to set up tamper-proof safety systems Simplifies machine maintenance through the Configuration Memory Card, which can be used to transfer the configuration program to a new CERTUS in just a few simple steps Ideal for machine designers Certified to the highest safety levels: SIL +, SILCL 3, PLe, Cat.4 Up to 128 inputs and 16 OSSD pairs Up to 14 expansion units in addition to the CMM Master, excluding relay modules Compact design: single module dimensions (W x H x D) 108 x 22.5 x 114.5 Product Description Ordering Key C MM Model CERTUS is the new Thanks to the new CERTUS Carlo Gavazzi modular modular structure, it Type configurable safety system. is possible to adapt This new safety device its I/O configuration is capable of monitoring and functionality to the several safety photocells, demands of many different emergency stops, applications making safety mats, magnetic CERTUS a highly versatile or mechanical switches, and flexible safety system. twohand controls etc. Type Selection Diagnostic and data CMM Programmable master unit communication family Expansion units for C 8I2O I/O expansion unit C 8I - C 16I Input expansion unit C PDP, C DNET, C CAN, Diagnostics and Data C EIP, C ECAT, C PFNET, Communication C 12I - C 8TO I/O expansion unit C OMMS C 2OSSD - C 4OSSD Output expansion unit Speed monitoring family Expansion units to monitor C 2R - C 4R Guided contact relay output C PSS, C ES1T, C ES2T, speed (PLe): zero, max and expansion unit. CBT Bus transfer expansion units C ES1H, C ES2H, C ES1S, range, plus motion direction, C ES2S rotation/translation General Data Over voltage category II Max. number of inputs 128 Max. number of outputs 16 Digital Inputs PNP active high, according to EN 61131-2 Max. number of expansion units 14 Digital otputs PNP active high Max. number of expansion 400mA 24VDC units of the same type 4 Response time Rated voltage 24VDC 20% Supply from class II (LVLE) Master 10,6 to 12,6ms + TInput filter 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/03/2015CERTUS Configurable Safety Module General Data CMM + 1 Expansion unit 11,8 to 26,5 + TInput filter Max. length of connections 100m CMM + 2 Expansion units 12,8 to 28,7 + TInput filter Operating temperature -10 to 55C CMM + 3 Expansion units 13,9 to 30,8 + TInput filter Max. sorrounding CMM + 4 Expansion units 15 to 33 + TInput filter air temperature 55C CMM + 5 Expansion units 16 to 35 + TInput filter Storage temperature +20 to 85C CMM + 6 Expansion units 17 to 37,3 + TInput filter Relative humidity 10% to 95% CMM + 7 Expansion units 18,2 to 39,5 + TInput filter Description Electronic housing max 24 CMM + 8 Expansion units 19,3 to 41,7 + TInput filter pole, with locking latch CMM + 9 Expansion units 20,4 to 43,8 + TInput filter mounting. CMM + 10 Expansion units 21,5 to 46 + TInput filter Enclosure material Polyamide CMM + 11 Expansion units 22,5 to 48,1 + TInput filter Enclosure protection class IP20 CMM + 12 Expansion units 23,6 to 50,3 + TInput filter Terminal blocks protection class IP2X CMM + 13 Expansion units 24,7 to 52,5 + TInput filter Fastening Quick coupling to DIN rail CMM + 14 Expansion units 25,8 to 56,4 + TInput filter according to EN60715 Connection cable C.G. proprietary 5-pole bus Dimensions (H x W x D) 108 x 22.5 x 114.5 2 Connection cable cross section 0,5 to 2,5 mm / AWG 12 to 30 (solid/stranded) Main Unit and Expansion Units Features CMM stand alone main unit: - 4 safety relays - 4 NO + 2 NC connectable to 2 independent - 8 safety inputs, 2 OSSD pairs - 400mA output current - OSSD pairs. with separate EDM and Start/Restart, 4 test outputs - 2/4 safety relays with 6A 250VAC guided contacts. and 2 programmable status outputs - 1/2 NC contacts for External Device Monitoring (EDM). - Configurable via PC through USB interface - CMC (CERTUS Configuration Memory Card) slot for C DDC Data and Diagnostic Communication expansion program storage (optional feature) units for connection to the most common industrial Fieldbus system: C 8I 2O expansion unit: C PDP - Profibus DP - 8 safety inputs, 2 OSSD pairs - 400mA output current - with C DNET - DeviceNet separate EDM and Start/Restart, 4 test outputs and 2 C CAN - CANopen programmable status outputs (same as CMM but no CPU). C EIP - Ether net IP C ECAT - EtherCAT C 8I and C 16I expansion units: C PFNET - PROFINET - 8 and 16 safety inputs, 4 test outputs. C OMMS - Universal Serial Bus C 12I 8TO expansion unit: CBT Bus transfer expansion unit, up to 50m length per - 2 safety inpus, 8 test otputs - can control up to 4-wire connection. Maximum of 6 connections per system safety mats. Speed Monitoring expansion units to monitor (PLe): C 2OSSD and C 4OSSD expansion units: Zero speed - 2 and 4 OSSD pairs - 400mA output current - with separate Max speed EDM and Start/Restart, 2/4 programmable status outputs. Speed range C EIP - Ether net IP Motion direction rotation / translation. C 2R and C 4R relay expansion units: - 2 safety relays - 2 NO + 1 NC connectable to 1 OSSD pair. Characteristic of the Output Circuit Excitation voltage 17...31 VDC Maximum switchable Minimum switchable voltage 10VDC voltage (AC) 400VAC Minimum switchable curent 20 mA Maximum switchable current 6A Maximum switchable Response time 12ms 6 voltage (DC) 250VDC Mechanical life of contacts > 20 x 10 2 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 18/03/2015

Tariff Desc

8517.62.00 51 No Modems, of a type using digital to analogue modulation and analogue to digital demodulation, being goods of a kind having operational transmission speeds of 300 bits/second or greater
Carlo Gavazzi Computing Solutions

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted