Product Information

EM24-DIN.AV9.3X.IS.P

EM24-DIN.AV9.3X.IS.P electronic component of Carlo Gavazzi

Datasheet
METER, EM24, 3 INPUT, MODBUS, 64A DIRECT

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 432.5605 ea
Line Total: USD 432.56

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Tue. 23 Apr to Mon. 29 Apr

MOQ : 1
Multiples : 1

Stock Image

EM24-DIN.AV9.3X.IS.P
Carlo Gavazzi

1 : USD 432.5605
5 : USD 422.3167

     
Manufacturer
Product Category
No Of Digits / Alpha
Meter Function
Meter Range
Digit Height
Panel Cutout Height
Panel Cutout Width
Supply Voltage Min
Supply Voltage Max
Operating Temperature Min
Operating Temperature Max
Svhc
Operating Temperature Range
Power Consumption
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 2

A82-20500 electronic component of Carlo Gavazzi A82-20500

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 3

AD2000 electronic component of Carlo Gavazzi AD2000

Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1

AQ1038 electronic component of Carlo Gavazzi AQ1038

Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1

AD1040 electronic component of Carlo Gavazzi AD1040

Power Analysers WM4-96 BASE REV.0
Stock : 1

AO1032 electronic component of Carlo Gavazzi AO1032

Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1

5100532 electronic component of Carlo Gavazzi 5100532

Panel Meters and Controllers Panel Meter Modular
Stock : 1

ACR1252U electronic component of Carlo Gavazzi ACR1252U

USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 11

AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC

LATCH UNIT 100-25A
Stock : 1

APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01

Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

Energy Management Energy Analyzer Type EM24 DIN Class 1 (kWh) according to EN62053-21 Class B (kWh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy 0.5 RDG (current/voltage) Energy analyzer Instantaneous variables readout: 4 DGT Energies/gas/water readout: 7+1 DGT System variables: VLL, VLN, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, Phase-sequence. Single phase variables: VLL, VLN, A, VA, W, var, PF Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs single phase measurements Gas, cold water, hot water, kWh remote heating measurements Hour counter (6+2 DGT) TRMS measurements of distorted sine waves (voltages/cur- rents) Self power supply (AV0-AV2-AV9 inputs) Auxiliary power supply (AV5-AV6 inputs) Application adaptable display and programming procedure 3 digital inputs for tariff selection, DMD synch or gas/ (Easyprog function) water (hot-cold) and remote heating metering (on request) Easy connections management 2 digital outputs for pulses or for alarms or as a mix of them Certified according to MID Directive (option PF only): (on request) see how to order below Dimensions: 4-DIN modules Other version available (not certified, option X and P): Protection degree (front): IP50 see how to order on the next page RS485 serial output (on request) (MODBUS-RTU), iFIX SCADA compatibility Dupline communication capability (DP option) Product Description Three-phase energy analyzer for DIN-rail mounting with IP50 Moreover the meter can be pro- alarm outputs. In alternative the with built-in configuration joy- (front) protection degree. Direct vided with digital outputs that RS485 communication port and stick and LCD data displaying connection up to 65A and by can be either for pulse propor- 3 digital inputs or Dupline port particularly indicated for active means of external current and tional to the active and reactive and 3 digital inputs are avail- and reactive energy metering potential transformers. energy being measured or for able as an option. and for cost allocation. Housing How to order EM24 DIN AV5 3 X O2 PF Certified according to MID Directive, Model Annex + Annex or Annex B + MID Range code Annex F for legal metrology relevant to System active electrical energy meters (see Annex MI-003 of Power supply MID). Can be used for fiscal (legal) metrology. Inputs/Outputs Option Type Selection for MID version Range codes System Inputs/Outputs Power supply AV5: 400V AC - 5(10)A LL XX: none X: Self power supply 3: 3-phase, 4-wire (CT connection) O2: dual open collector (See Power supply balanced load AV2: V : 113V to 230V LN LN type (dual pulse or one specifications) V : 230V to 400V LL LL pulse + one alarm or D: 115/230VAC (50Hz) I: 10(65)A dual alarm) AV9: 400V AC - 10(65)A LL IS: 3 digital inputs for tariff (direct connection) selection or Gas/Water/ remote heating meter- ing plus RS485 port Options NOTE: please check the DP: Dupline port plus 3 dig- ital inputs for Gas/ availability of the needed PF: Certified according to MID Directive, Annex + Annex water/ remote heating code on the verification path or Annex B + Annex F for legal metrology relevant metering tables below before order . to active electrical energy meters (see Annex MI-003 of MID). Can be used for fiscal (legal) metrology. AV5 3 D XX AV9 3XPXXF O2 O2 PF IS IS AV2 3 DP X Specifications are subject to change without notice EM24 DIN DS 051110 1 Range System Power supply Input/Output Option Range System Power supply Input/Output OptionEM24 DIN How to order EM24 DIN AV5 3 X O2 X STANDARD Model Range code System Not certified according to MID directive. Cannot be Power supply used for fiscal (legal) metering. Inputs/Outputs Option Type Selection for standard version Range codes System Inputs/Outputs Power supply AV5: 400V AC - 1/5 (10)A LL 1: 1-phase, 2-wire XX: none X: Self power supply (CT connection) 3-phase, 3-wire, O2: dual open collector (See Power supply V : 160 V to 480V LN LN 3-phase, 4-wire type (dual pulse or one specifications) V : 277 V to 830V LL LL balanced load (*) pulse + one alarm or L: 18 to 60VAC/DC (48 to AV6: 208V AC - 1/5(10)A LL 3: balanced and dual alarm) 62Hz) (*) (VT/PT and CT unbalanced load: R2: dual relay type (func- D: 115/230 VAC (48 to connections) 3-phase, 4-wire tions as per O2) (*) 62Hz) V : 40V to 144V LN LN 3-phase, 3-wire XS: RS485 port (*) V : 70V to 250V LL LL 2-phase, 3-wire IS: 3 digital inputs for tariff AV0: 208V AC -10(65)A LL 1-phase, 2-wire selection or Gas/ (direct connection) (*) water/ remote heating Options V : 96V to 144V LN LN metering plus RS485 V : 166V to 250V LL LL port (*) on request. X: none AV2: 400V AC 10(65)A LL DP: Dupline port plus 3 dig- P: Bearing EC. Type (direct connection) (*) ital inputs for Gas / NOTE: please check the examination (annex B V : 113V to 265V LN LN water / remote heating of MID) relevant to V : 196V to 460V availability of the needed LL LL metering active electrical energy AV9: 400V AC - 10(65)A LL code on the verification path meters (see Annex MI- (direct connection tables below before order. 003). V : 184V to 276V LN LN V : 318V to 480V LL LL AV5 3 XX D P AV9 3 XX X P IS IS DP L XS X XS R2 XX R2 DP D L 1 XX XX 1 AV0 IS IS 3 DP DP XS XS R2 R2 AV6 1 XX D X AV2 3XX XP 3 XS L O2 IS IS DP DP R2 XS XX 1 XX O2 XS IS DP 2 Specifications are subject to change without notice EM24 DIN DS 051110 Range System Input/Output Power supply Option Range System Input/Output Power supply Option

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted