Product Information

GCA32A110VAC50/60HZ

GCA32A110VAC50/60HZ electronic component of Carlo Gavazzi

Datasheet
Industrial Relays COIL CC32-40A 110VAC 50/60HZ

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

2: USD 26.1214 ea
Line Total: USD 52.24

0 - Global Stock
MOQ: 2  Multiples: 2
Pack Size: 2
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 23 May to Wed. 29 May

MOQ : 2
Multiples : 2

Stock Image

GCA32A110VAC50/60HZ
Carlo Gavazzi

2 : USD 26.1214
5 : USD 23.3846
10 : USD 22.4039

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 1

A82-20500 electronic component of Carlo Gavazzi A82-20500

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 3

AD2000 electronic component of Carlo Gavazzi AD2000

Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1

AQ1038 electronic component of Carlo Gavazzi AQ1038

Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1

AD1040 electronic component of Carlo Gavazzi AD1040

Power Analysers WM4-96 BASE REV.0
Stock : 1

AO1032 electronic component of Carlo Gavazzi AO1032

Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1

5100532 electronic component of Carlo Gavazzi 5100532

Panel Meters and Controllers Panel Meter Modular
Stock : 1

ACR1252U electronic component of Carlo Gavazzi ACR1252U

USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0

AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC

LATCH UNIT 100-25A
Stock : 1

APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01

Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1

Image Description
AZ2510P2-1A-24D electronic component of Zettler AZ2510P2-1A-24D

Electromechanical Relay SPST-N
Stock : 1

RPM12B7 electronic component of Schneider RPM12B7

Industrial Relays PLUG-IN RELAY 250V 1 5A RPM
Stock : 1

2966919 electronic component of Phoenix Contact 2966919

Industrial Relays PLC-RSC- 12DC/21AU RELAY PN 651-2961163
Stock : 1

RSB2A080RD electronic component of Schneider RSB2A080RD

Industrial Relays PLUG-IN RELAY 250VAC 8A RSB
Stock : 0

RXM2AB3F7 electronic component of Schneider RXM2AB3F7

Industrial Relays Plug-in Relay 250V 10A RXM+LED NO MAN
Stock : 1

2902955 electronic component of Phoenix Contact 2902955

Industrial Relays PLC-RSC-24DC/21 ATEX
Stock : 1

2966223 electronic component of Phoenix Contact 2966223

Industrial Relays PLC-RSC-24DC/1/SEN
Stock : 1

R4N-2014-23-5012-WT electronic component of Relpol R4N-2014-23-5012-WT

Relay: electromagnetic; 4PDT; Ucoil:12VAC; 6A/250VAC; 6A/24VDC
Stock : 0

RM84-2012-25-5230 electronic component of Altech RM84-2012-25-5230

Industrial Relays Miniature relay, DPDT
Stock : 1

RM84-2012-25-5110 electronic component of Altech RM84-2012-25-5110

Industrial Relays relay 110VAC coil 50/60HZ
Stock : 0

Programming Unit Du line Type GAP 1605 Fieldbus Installationbus Portable programming unit Individual coding of every input or output Group coding of an entire module Reading of codes Editing of channel codes On/off-line coding of Dupline modules type G .... LED display 4 x 8 LEDs 5-key tactile keyboard Battery powered Easy-to-handle plug-type connection Switch for turning power on/off Product Description Ordering Key GAP 1605 Programming unit for Dupline and 8 successive channels or Type: modules G..(..) .... Provides individually for each I/O. Dupline Programmer means of reading and pro- Unused inputs/outputs can be Type no. gramming of channel codes. defined as non-coded. Coding of I/O s as either 2, 4 Supply Specifications Type Selection Supply Ordering no. Power supply 9 V Alkaline 400 mAH Internal battery GAP 1605 Battery type IEC 6F22 Rated operational power Stand-by < 25 A Operating < 22 mA Battery lifetime Typ. 1 year Product Specifications General Specifications Output Environment Connection 6/6 modular socket Degree of protection IP 40 Pollution degree 3 (IEC 60664) Display 4 x 8 dots Operating temperature 0 to +50C (+32 to +122F) Type LED Storage temperature -20 to +60C (-4 to +140F) Size 1.8 mm Humidity (non-condensing) 20 to 80% RH Keyboard Tactile keys No. of keys 5 Mechanical resistance Shock 15 G (11 ms) Cable GAP 1605 to Dupline system Vibration 2 G (6 to 55 Hz) Connectors 2 x 6/6 modular plugs Length 75 cm Material ABS, grey Weight 225 g Specifications are subject to change without notice (04.03.2009) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupGAP 1605 Du line Fieldbus Installationbus Mode of Operation The GAP 1605 is a portable Group - Key Prog - Key It is possible to change all programming unit used for When the displayed I/O- eight Inputs/Outputs, even reading or programming Used to select the Group coding corresponds to the though some Dupline mod- channel code(s) in the series address within the range A desired channel configura- ules are built for only 1, 2 or of Dupline products. to P. The Group LED will tion, the codes will be 4 Inputs/Outputs. shift one position right for downloaded to the Dupline each key activation. module when pressing the Prog key. The external switch turns To exit single channel pro- the power on/off. gramming, just keep the When the battery is installed Channel - Key In/Out key pressed for 2 and the power is on, the After programming is exe- seconds. GAP 1605 is ready for use. Used to select the chan- cuted, a verification takes Connect the cable between nel(s) within the group. The place. If this verification the programming unit and a Channel LED will shift right fails, all activated LEDs in Dupline module type G.. one, two or four positions, the display will flash two Output status setting depending on the number of times, and the programming inputs/outputs. If consecu- unit will switch off. On receivers it is possible to tive channels are selected, configure the status of the 5 keys provide the means of then pressing the Channel outputs during Dupline fail- operating the GAP 1605: key will have no effect. ure. Normally, any output of two keys are used for read- If such behaviour occurs re- a receiver will go off during ing and programming, two peatedly on the same mod- Dupline failure. In some cas- keys for changing Groups ule, the module may be es the inverted function is and Channels and one key Read / On - Key faulty. If several modules fail desirable (e.g. light applica- for selecting the desired to download, the GAP 1605 tions - turn on light if the Input/Output. Used to turn on the GAP may be faulty. Dupline is down). 1605 and to read the chan- nel codes of the connected module. When the reading is The current coding is dis- completed, the display will Individual In/Out channel To change output status, the played by 4 x 8 LEDs. The show the channel code of programming GAP 1605 must be put into top row of LEDs displays the the module: either 1, 2, 4 or configuration mode. This is selected input or output. 8 inputs/outputs. The GAP 1605 features an done as follows: The two middle rows display additional mode of single- Remove any connected the current channel group, channel editing. Pressing Dupline system. while the bottom row dis- In/Out for more than 2 Keep both In/Out and plays the current channel 2, 4 or 8 In/Out LED s being seconds will change the Group pressed, while code. ON indicates that consecu- operating mode to single- pressing Read/On . tive channel codes are allo- point programming. The cated to the I/O s, e.g. input In/Out key is now used 1 coded to P1, input 2 to P2 to select one of the eight In/Out - Key ... input 8 to P8. possible inputs/output, thus The first In/Out LED now making individual channel turns on. Connect the Dupline This key is used to scroll coding possible. The In/Out- system, and press Read/ through the I/O s of a mod- LEDs assign the display On . If output status is set, ule. If a new module is con- If only one In/Out LED is channel code to the corre- then channel LED 1 will illu- nected or if consecutive ON, then the I/O s are cod- sponding physical input/out- minate. Pressing Channel channel codes are allocated ed individually, e.g. input 1 put of the module. will toggle the output status to the I/O s, pressing the to C5, input 2 to D4 etc. The On/Off. In/Out key has no effect code for each I/O is indicat- Press Prog to store. since all Dupline modules ed by a group LED and a If Read/On is pressed are preprogrammed to their channel LED. In singlemode the Chan- when no Dupline system is physical number of inputs/ nel key also has the ability connected, the LEDs will outputs. This key is also to disable an In/Out-position. flash to indicated a false used to switch between Channel must simply be condition. Only a successful consecutive and individual If the GAP 1605 is not con- pressed past channel 8, reading will reset this condi- coding of the I/O s. To nected to a Dupline system, whereby both the Channel tion. change the mode, keep it will turn off within two se- LED and the Group LED will In/Out pressed for more conds. turn off. To reenable, just than 2 seconds. press Channel again. 2 Specifications are subject to change without notice (04.03.2009) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group

Tariff Desc

8536.49.00 TC17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC8909066 RELAYS having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mmx30mmx27mm

8536.49.00 TC9613322 RELAYS low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24mm
(b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8AAC

8536.49 TC8906734 RELAYS having ALL of the following:
(a) one, two or three contacts
(b) maximum continuous contact current rating of NOT less than 15A
(c) maximum contact voltage rating of NOT less than 380V
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC1122469 RELAYS having an operating voltage NOT exceeding 250volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC8534635 RELAYS cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5A (AC or DC);
(b) switching voltage NOT exceeding 250V (AC or DC);
(c) body dimensions NOT exceeding 31mm x36mm x19mm

8536.49 TC8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8538.90.90 08 .. For programmable controllers Other Free
Carlo Gavazzi Computing Solutions

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted