Product Information

NSO13DB24DA

NSO13DB24DA electronic component of Carlo Gavazzi

Datasheet
I/O Modules SAFETY GATES MODULE 2NO IN 3 OUT

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 937.0656 ea
Line Total: USD 937.07

5 - Global Stock
Ships to you between
Tue. 07 May to Mon. 13 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
5 - WHS 1


Ships to you between Tue. 07 May to Mon. 13 May

MOQ : 1
Multiples : 1

Stock Image

NSO13DB24DA
Carlo Gavazzi

1 : USD 933.2662
3 : USD 893.0644
5 : USD 879.6638
10 : USD 866.4599

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 2

A82-20500 electronic component of Carlo Gavazzi A82-20500

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 3

AD2000 electronic component of Carlo Gavazzi AD2000

Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1

AQ1038 electronic component of Carlo Gavazzi AQ1038

Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1

AD1040 electronic component of Carlo Gavazzi AD1040

Power Analysers WM4-96 BASE REV.0
Stock : 1

AO1032 electronic component of Carlo Gavazzi AO1032

Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1

5100532 electronic component of Carlo Gavazzi 5100532

Panel Meters and Controllers Panel Meter Modular
Stock : 1

ACR1252U electronic component of Carlo Gavazzi ACR1252U

USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0

AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC

LATCH UNIT 100-25A
Stock : 1

APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01

Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1

Image Description
70G-OAC5-L electronic component of Grayhill 70G-OAC5-L

I/O Modules ASM,120VAC 3.5A AC OUTPUT MOD AC, 5Vdc logic, 120Vac load
Stock : 1

3-1393028-8 electronic component of TE Connectivity 3-1393028-8

I/O Modules AC input 5VDC 3A 24-280AC out Blk
Stock : 1

70G-ODC24 electronic component of Grayhill 70G-ODC24

I/O Modules 24 VDC Logic 3.5 A 3-60Vdc Fast
Stock : 11

Hot 70G-OAC24 electronic component of Grayhill 70G-OAC24

I/O Modules I/O Module G5 digital output 24Vdc
Stock : 1

OACM-5 electronic component of TE Connectivity OACM-5

AC Output Module Output Module 3A 24 ~ 280VAC Output 5VDC Supply
Stock : 1

G3R-IAZR1SN AC100-240 electronic component of Omron G3R-IAZR1SN AC100-240

AC Input Module Output Module 100mA 4 ~ 32VDC Output 100 ~ 240VAC Supply
Stock : 0

G3R-IDZR1SN DC5 electronic component of Omron G3R-IDZR1SN DC5

I/O Modules SOLID STATE RELAY
Stock : 16

G78-04 electronic component of Omron G78-04

I/O Modules Relay Block Short Bar
Stock : 6

6402 electronic component of Sensata 6402

Sensata Technologies
Stock : 1

SM-OAC5A electronic component of Sensata SM-OAC5A

I/O Modules 24-280 VAC Output
Stock : 11

Safety Modules Safety Gate and Safety Magnetic Sensor Types NSO02D, NSO13D Safety Category 4, Performance Level e, according to EN 13849-1 Safety Category 4 according to EN 954-1 Category 0 Emergency Stop (EN 60204-1) Input type: 2 NO 2 x 6 A NO safety outputs (NSO02D) 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NSO13D) Automatic / manual or monitored manual reset Single / double channel operations LED indication for outputs status and power supply ON Connection by fixed or detachable terminals For mounting on DIN-rail in accordance with DIN/EN 50 022 22.5 mm Euronorm housing Screw, fixed Screw, detachable Product De scrip tion Ordering Key N SO 0 2 D B24 S A Safety gate and safety Performance Level e, Housing magnetic sensor modules includes fixed screw and Function according to EN 60204-1, EN detachable screw as well as Auxiliary outputs 292-1/-2, EN 418 andautomatic/manual or Safety outputs EN1088. monitored manual restart Safety category This family of safety module versions. Power supply in Safety Category 4, Terminals Start/Reset type Type Selection Auxiliary Safety Terminals Start/Reset type Supply: 24 VAC/DC outputs outputs 2 NO Screw, fixed Automatic / Manual N SO 0 2 D B24 S A 2 NO Screw, fixed Monitored manual N SO 0 2 D B24 S C 2 NO Screw, detachable Automatic / Manual N SO 0 2 D B24 D A 2 NO Screw, detachable Monitored manual N SO 0 2 D B24 D C 1 NC 3 NO Screw, fixed Automatic / Manual N SO 1 3 D B24 S A 1 NC 3 NO Screw, fixed Monitored manual N SO 1 3 D B24 S C 1 NC 3 NO Screw, detachable Automatic / Manual N SO 1 3 D B24 D A 1 NC 3 NO Screw, detachable Monitored manual N SO 1 3 D B24 D C Time Specification Output Specification Delay ON energisation < 150 ms Safety outputs Category 4, Performance Level e (EN 13849-1) Delay ON de-energisation < 30 ms NSO02D 2 NO (13-14, 23-24) Recovery time 30 ms NSO13D 3 NO (13-14, 23-24, 33-34) Channel simultaneity Auxilary output during outputs closing Infinite NSO13D 1 NC (41-42) Input operating to START Rated insulation voltage 250 VAC (rms) operating delay Contact ratings (AgSnO ) 2 m Au NSO...C > 500 ms 2 Safety outputs Resistive loads AC1 6 A 230 VAC DC12 6 A 24 VDC Input Specifications Small inductive loadsAC15 3 A 230 VAC DC13 2.5 A 24 VDC Function 2 NO, voltage free Auxiliary output 6A, 24 VAC/DC Input current External contact fuse Terminals S11-S12 max 10 mA protection 5 A fast, 4 A slow Terminals S21-S22 max 10 mA 7 Mechanical life > 10 operations External contact resistance 5 Terminals S11-S12 max. 60 Electrical life > 10 operations Terminals S21-S22 max. 60 Dielectric strength Dielectric voltage 4 kVAC (rms) 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 27/09/12 NSO02D, NSO13D Supply Specification General Specifications Power supply Overvoltage cat III Indication for Rated operational volatge (IEC 60664) Power supply ON LED, green through terminal: Output relays ON LED, green (CH 1, CH2) A1, A2 24VAC - 15% / 10%, Environment (EN 60529) 50 to 60 Hz Degree of protection IP 20 24 VDC - 15% / +10% Pollution degree 2 Short circuit protection Internal PTC Operating temperature -25 to 65C, R.H. < 95% Storage temperature -30 to 65C, R.H. < 95% Dielectric voltage DC supply AC supply Supply to input none none Mimimum protection degree Supply to output 4 kV 4kV of the installation location IP 54 Input to output 4kV 4kV Housing dimensions 22.5 x 99 x 114 mm Rated operational voltage max 5 VA Weight Approx. 200 g Screw terminals Tightening torque Upper terminals Max. 0.5 Nm Lower terminals Max 0.8 Nm Approvals CULUS, TUV CE Marking Yes EMC Electromagnetic Compatibillity Immunity According to EN 61000-6-2 Emission According to EN 61000-6-3 Mode of Operation The safety modules NSO02D Automatic START Manual START Monitored manual START and NSO13D monitor both Provided that the terminals X1 Provided that both S1 and S2 The monitored manual START mechanical switches and and X2 (NSO02...A) or S33 switches are closed, the safety versions (NSO...C) work as safety magnetic sensors (2 NO and S34 (NSO13...A) are outputs close and the auxiliary described in the previous contact outputs), according to connected, the safety outputs output opens (NSO13...A) as paragraph (Manual START) 98/37/CE Machinery Directive. close and the auxiliary output soon as the NO START except for a minimum delay of If the unit is correctly supplied opens (NSO13...A) as soon as pushbutton is pushed 500 ms from the closed status and the input terminals are both S1 and S2 switches are connecting X1 and X2 of the input contacts to the closed (i.e. safety gate closed), closed. (NSO02...A) or S33 and S34 pushing of the START button. the module is enabled to close The relevant CH1 and CH2 (NSO13...A) If the input terminals get the safety outputs and the LED turn on. A new operating cycle is closed with the START switch external contactors can be Releasing even one input possible only after releasing already closed, the safety energized. contact (S1 and/or S2) forces both input contacts, closing outputs dont close and the When the input terminals are immediately the safety outputs them again and pushing the auxiliary doesnt open open (i.e. safety gate open) the to open and the auxiliary START button. (NSO13...C): it is necessary to module is not enabled to close output (NSO13...A) to close. release the START button and the safety outputs and the A new operating cycle is the input contacts before external contactors can not be possible only after releasing starting a new cycle, then energized. both input contacts and then operate the input contacts and operating them again. finally, after at least 500 ms, operate the START button. So if the NO START button gets welded, the outputs dont close anymore. Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 27/09/12 2

Tariff Desc

8542.3 - Electronic integrated circuits:
8542.31.00 -- Processors and controllers, whether or not combined with memories, converters, logic circuits, amplifiers, clock and timing circuits, or other circuits
Monolithic integrated circuits:
.Digital:
61 No ..Linear/analogue and peripheral integrated circuits, timers, voltage regulators, A/D and D/A converters, telecommunication and modem integrated circuits, other than board level products
62 No ..Other
63 No Hybrid integrated circuits
64 No Multichip integrated circuits
Carlo Gavazzi Computing Solutions

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted