Motor Controllers Industrial, 2-Phase Motor Reversing Type RR2A Motor reversing for 3-phase induction motors up to 5.5 kW Rated operational voltage: Up to 480 VACrms Built-in interlock function DC or AC control voltage Built-in voltage transient protection LED indication for direction Isolation: Optocoupler (input-output) 4000 VACrms Direct copper bonding technology Product Des cript ion Ordering Key RR 2 A 40 D 150 This family of 2-Phase Motor at ions (tran sients) by built-in Motor reversing Reversing Controller is de - varistors. Fur therm ore, op ti- Number of phases signed to control the directon mum re lia bil i ty is achieved by Switching mode of 3-phase motors rated up to sol deri ng the output thyristor Rated operational voltage 5.5 kW. The built-in in ter lock- chips dir ec t ly on to the Control input type ing circuitry pre vents the relay ceramic substrate (Di rect Motor power rating from switchi ng both di rec- Copper Bondi ng). tions simultaneously and pro- duce a short-circuit between The housing is designed to the 2 phases of the output. A incorporate a temperature dual col our LED ind i cates di- lim it switch. It is recommend- rec tionforw ar when green ed to install an appropriate and di rec tionre vers when semi c on duct or fuse in series red. The output is pro tect ed with the relay. from exc ess ive volta ge fluc tu - Type Selection Switching mode Rated ope ra t ion al Control voltage Motor rating voltage, Ue A: Zero Switching 40: 400 VACrms D: 10 - 40 VDC 150: 1.5 kW, 2 HP 48: 480 VACrms LA: 90 - 140 VAC 220: 2.2 kW, 3 HP HA: 180 - 265 VAC 400: 4.0 kW, 5 HP 550: 5.5 kW, 7.5 HP Selection Guide Rated op er a- Control Motor rating tiona l voltage voltage 1.5 kW 2.2 kW 4.0 kW 5.5 kW 10 to 40 VDC RR2A40D150 RR2A40D400 400 VACrms 90 to 140 VAC RR2A40LA150 RR2A40LA400 180 to 265 VAC RR2A40HA150 RR2A40HA400 480 VACrms 10 to 40 VDC RR2A48D220 RR2A48D550 90 to 140 VAC RR2A48LA220 RR2A48LA550 180 to 265 VAC RR2A48HA220 RR2A48HA550 General Spec if i ca tions RR2 A 40... RR2 A 48 . 220 RR2 A 48 . 550 Operational voltage range 40 to 440 VACrms 40 to 530 VACrms 40 to 530 VACrms Blocking voltage 1200 V 1200 V 1600 V p p p Operational frequency range 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz Power factor 0.5 400 VACrms 0.5 480 VACrms 0.5 480 VACrms LED on indication Yes (Green for Forward, Red for Reverse) Specifications are subject to change without notice (12.10.2017) 1RR2A Input Spec if i ca tions RR2A..D... RR2A..LA... RR2A..HA... Control voltage range 10 - 40 VDC 90 - 140 VAC 180 - 265 VAC Pick-up voltage 8.5 VDC 70 VAC 170 VAC Input current range 10 - 20 mADC 7 - 12.5 mAAC 6 - 9.5 mAAC Drop-out voltage 3.5 VDC 20 VAC 50 VAC Response time input to output 10 ms 70 ms 100 ms Time delay F R, R F Typical 80 ms 200 ms* 200 ms* Minimum 50 ms 30 ms 30 ms Maximum 90 ms 300 ms 300 ms * 300 ms for surrounding temperatures + 60C (140 F) Output Speci f ic at ions RR2A40.150 RR2A48.220 RR2A40.400 RR2A48.550 IEC and CCC rated operational current Ie (AC-53a) Ta = 40C 5 A 5 A 11 A 11 A IEC rated operational current Ie (AC-51) Ta = 40C 25 A** 25 A** 40 A** 40 A** Assigned motor rating 40C/ UL rating 40C 1.5kW / 2HP 2.2kW / 3HP 4.0kW / 5HP 5.5kW / 7.5HP Overload cycle according to EN/IEC 60947-4-2 40C 5A: AC53a: 6-6: 100-60 5A: AC53a: 6-6: 100-60 11A: AC53a: 8-3: 100-40** 11A: AC53a: 8-3: 100-40** Number of starts/hr 40C 60 60 40 40 Unlimited starts/hr 40C 4A: AC53a: 6-6: 100 4A: AC53a: 6-6: 100 5A: AC53a: 6-3: 100 5A: AC53a: 6-3: 100 - unlimited** - unlimited** - unlimited** - unlimited** 3.5A: AC53a: 5-6: 100 3.5A: AC53a: 5-6: 100 4A: AC53a: 5-3: 100 4A: AC53a: 5-3: 100 - unlimited* - unlimited* - unlimited* - unlimited* 1.5A: AC53a: 4-6: 100 1.5A: AC53a: 4-6: 100 2A: AC53a: 5-3: 100 2A: AC53a: 5-3: 100 - unlimited - unlimited - unlimited - unlimited Minimum operational current Ta = 25C V out = 40Vrms 150 mArms 150 mArms 250 mArms 250 mArms Off-state leakage current 1 mArms 1 mArms 1 mArms 1 mArms Non-rep. surge current t=10ms 300A 350A 350A 350A p p p p 2 2 2 2 2 I t for fusing t= 10ms 525 A s 525 A s 1800 A s 1800 A s On-state voltage drop 1.6 Vrms 1.6 Vrms 1.6 Vrms 1.6 Vrms Critical dv/dt off-state 500 V/us 500 V/us 1000 V/us 1000 V/us * This overload cycle is applicable when device is mounted on heatsink type RHS300 ** Applicable only when device is mounted on heatsink type RHS301 Environmental Specifications Operating temperature -20C to +80C Degree of Protection IP10 (EN/IEC 60529) (-4F to +176F) Installation category III Storage temperature -40C to +100C Installation Altitude 1000m (-40F to +212F) Vibration Relative humidity <95% non-condensing 40C Sinusodial (IEC 60068-2-6) 13 to 25Hz: 2.0mm peak Pollution Degree 3 2 25 to 150Hz: 20m/s 2 Specifications are subject to change without notice (12.10.2017)