Ultrasonic Diffuse, Analogue and Digital Output Types UA30CAD......TI Cylindrical M30 PBT housing Sensing distance: 250-3500 mm Power supply: 12 (15) to 30 VDC Outputs: 0-10 VDC or 4-20 mA and one switching output NPN or PNP. Linearity error 0.5% Repeatability 0.2% Beam angle. 6 Protection: Short-circuit, reverse polarity and overvoltage Protection degree IP 67, Nema 4X 2 m cable or M12 plug Product Description Ordering Key UA30CAD35NGM1TI A family of diffuse ultrasonic The sensor is the ideal choice Ultrasonic sensor sensors with sensing range for distance measurement, Housing style from 250-3500 mm with a level measurement, diameter Housing size resolution as low as 2.0 mm. measurement or loop control. Housing material The sensor contains both an Due to use of microproces- Housing length analogue and a digital output. sor control the digital filtering Detection principle The output is either 0-10V or makes the sensor immune to Sensing distance 4-20 mA and the digital output most electromagnetic inter- Output type NPN or PNP, NO or NC which ferences. Output configuration forms a windows detection. Connection Teach-in Type Selection Housing Connec- Rated operating Analog Digital output Ordering no. diameter tion dist. (S) Output NPN/PNP n M30 Plug M12 250-3500 mm 4-20 mA NPN UA 30 CAD 35 NG M1 TI M30 Cable 250-3500 mm 4-20 mA NPN UA 30 CAD 35 NG TI M30 Plug M12 250-3500 mm 0-10 V NPN UA 30 CAD 35 NK M1 TI M30 Cable 250-3500 mm 0-10 V NPN UA 30 CAD 35 NK TI M30 Plug M12 250-3500 mm 4-20 mA PNP UA 30 CAD 35 PG M1 TI M30 Cable 250-3500 mm 4-20 mA PNP UA 30 CAD 35 PG TI M30 Plug M12 250-3500 mm 0-10 V PNP UA 30 CAD 35 PK M1 TI M30 Cable 250-3500 mm 0-10 V PNP UA 30 CAD 35 PK TI Specifications Rated operating distance (S ) Reference target: 1 mm Rated operational voltage (U ) n B metal rolled finish, size NG or PG versions 12 to 30 VDC 200 x 200 mm. NK or PK versions 15 to 30 VDC 250 - 3500 mm (ripple included) Blind zone 250 mm Ripple (U) 5% rpp Repeatability 0.2% No-load supply current (I ) 50 mA U max o B Linearity error 0.5% Output current continuous digital output (I ) Beam angle 6 e Max. load capacity 100 nF 100 mA Sensitivity Output current short-time Push-button P1 (longest setpoint) digital output (I) P2 (shortest setpoint) Max. load capacity 100 nF 100 mA Resolution 2 mm Minimum operational current Temperature drift 0.1%/C -20 to +70 C digital output (I ) 0.5 mA m Temperature compensation Yes OFF-state current digital Hysteresis (H) Min. 0.5% output (I ) 10 A r Specifications are subject to change without notice (12.05.2014) 1UA30CAD.. Specifications (cont.) Voltage drop digital output (U ) 2.2 VDC 100 mA Environment d Installation category lll (IEC 60664/60664A Protection 60947-1) Digital output Short-circuit, overvoltage Pollution degree 3 (IEC 60664/60664A pulses and reverse polarity 60947-1) Supply Overvoltage pulses and Degree of protection IP67 (IEC 60529 60947-1) reverse polarity Nema 4X Analogue output Overvoltage pulses Ambient temperature Analog output Operating -20 to +70C (-4 to +158F) NG.. or PG.. types 4 to 20 mA Storage -35 to +70C (-31 to +158F) NK.. or PK.. types 0 to 10 VDC Vibration 10 to 55 Hz, 1.0 mm/6G. Load (IEC/EN 60068-2-6) 4 to 20 mA max. 500 0 to 10 VDC min. 3 k Shock 30 g / 11 mS, 3 directions (IEC/EN 60068-2-27) Carrier frequency 112 kHz Rated insulation voltage < 500 VAC (rms) Operating frequency digital output (f) 2 Hz Housing Material body PBT Response time OFF-ON Material front Epoxy-glass resin digital output (t ) 250 mS ON Material back, plug Grilamid Response time ON-OFF Material back, cable Grilamid digital output (t ) 250 mS OFF Material push-button TPE Response time analog output 500 mS Sealing around push-button TPE Material sealing front TPE Power ON delay 500 mS Connection Output function, open Cable PVC, grey, 2 m, collector 2 4 x 0.34 mm , = 4.7 mm By sensor type NPN or PNP Plug M12, 4-pin (CON. 14-series) Output switching function One open collector transis- Tightening torque 1.5 Nm tor and one analogue output to be configured as: Weight - Windows function with Cable version 160 g N.O or N.C. output. Plug version 90 g - Analogue output with CE-marking Yes positive or negative slope. Approvals cULus (UL508) Indication Output ON Yellow LED Echo received Green LED Wiring Diagram Detection Range X Target Y Sensor Distance (feet) BN1 BN1 WH2 WH2 0 1.6 3.3 4.9 6.6 8.2 9.8 11.5 400 15.7 BK4 BK4 PNP: U I 300 11.8 BU3 BU3 200 7.9 100 3.9 Voltage Current 0 0 BN1 BN1 -100 -3.9 I BK4 BK4 UU -200 -7.9 NPN: WH2 WH2 -300 -11.8 BU3 BU3 -400 -15.7 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Distance (m) 2 Specifications are subject to change without notice (12.05.2014) Parallel displacement (mm) Parallel displacement (inch)