S/SMR8621520/B/16/03/2021 Sightpac page 1 / 5F/GB Relais statique triphas de puissance Three phase power solid state relay SMR8621520 Output : 24-520VAC Zero cross solid State Relay especially designed to control and reverse the direction of three phase motors (2.2 kW max). Input : 12-30VDC Protection on input (interlocking, temporisation between each reverse) and output AC53: 3x5A (moteur / motor) (RC+VDR). Large control range: 12-30VDC with input current limiter. Green LED visualization on the input. Double Push-in spring power terminals. Designed in conformity with IEC/ EN60947-4-2. Built in IP20. Relais statique synchrone spcialement adapt pour dmarrer et inverser le sens de rotation de moteurs triphass (2,2kW max). Protection sur l entre (interverrouillage, temporisation entre chaque inversion) et sur la sortie (VDR+RC). Large plage de contrle: 12-30VDC avec un courant de commande rgul. LED de visualisation sur l entre de couleur verte. Connecteurs de puissance ressort typepush-i doubls. Construit en conformit aux normes IEC/EN60947-4-2. Protection contre le toucher IP20. Typical application / Application typique: Synoptic / Synoptique: L1 L2 L3 3/L2 5/L3 1/L1 Organe de protection/ 7/+ Control Protection equipment logic 8/+ 9/- 10/- 1/L1 3/L2 5/L3 Alimentation DC F R RC + VDR / DC supply 10/- 9/- 8/+ 7/+ protection 4/T2 6/T3 2/T1 F R + 4/T2 6/T3 2/T1 F : Forward R : Reverse Moteur / Motor Proud to serve you All technical caracteristics are subject to change without previous notice. Caractristiques sujettes modifications sans pravis. r e l a i s INSULATION INSULATION S/SMR8621520/B/16/03/2021 Sightpac page 2 / 5F/GB Control characteristics (at 25C) / Caractristiques de commande ( 25C) DC Symbol Min Nom Max Unit Parameter / Paramtre Uc 12 30 V Control voltage / Tension de commande Ic 15 25 mA Control current ( Uc ) / Courant de commande Uc off 6 V Release voltage / Tension de relachement Reverse voltage / Tension inverse -Uc 30 V Output characteristics (at 25C) / Caractristiques de sortie (25C) Parameter per leg / Paramtre par voie Conditions Symbol Min Typ. Max Unit Operating voltage range / Plage de tension d utilisation Ue 24 400 520 V rms Peak voltage / Tension crte Up 1200 V Zero cross level / Niveau de synchronisme Usync 10 V Latching voltage / Tension minimum amorage Ie nom Ua 10 V Nominal current / Courant nominal 40C (AC-53) Ie AC-53 5 A rms Non repetitive overload current / Courant de surcharge tp=20ms Itsm 240 252 A On state voltage drop / Chute directe l tat passant 25C Vt 0,85 V On state dynamic resistance / Rsistance dynamique rt 20 m Output power dissipation (max value) / Puissance dissipe Pd 0,9x0,85xIe + 0,02 x Ie W (max) Thermal resistance between junction to case (one leg) Rthj/c 1,7 K/W Rsistance thermique jonction/semelle (1 voie) Off state leakage current / Courant de fuite l tat bloqu Ue typ, 50Hz Ilk 1 mA Minimum load current / Courant minimum de charge Iemin 5 mA Turn on time / Temps de fermeture (cycles) ton max 0,5 Turn off time / Temps d ouverture (cycles) toff max 0,5 Time delay between each inversion (ms) / Temporisation 70 ms entre chaque inversion (ms) Operating frequency range / Frquence utilisation F mains f 0,1 50-60 400 Hz Off state dv/dt / dv/dt l tat bloqu dv/dt 500 V/s Maximum di/dt non repetitive / di/dt max non rptitif di/dt 50 A/s 2 2 I2t (<10ms) I t 380 A s Conducted immunity level / Immunit conduite IEC/EN61000-4-4 (bursts) 4kV criterion A Conducted immunity level / Immunit conduite IEC/EN61000-4-5 (surge) 4kV criterion A Fuse MERSEN type 25 aM Short circuit protection / Protection court-circuit ( 100kA) type 2 coordination Example Overload currents / Courants de surcharges: 1 - No repetitive Itsm is given without voltage reapplied . This curve is used to define the protection (fuses). 1 - Itsm non rptitif (1) sans tension rapplique est donn pour la dtermination des protections. 2 - Repetitive Itsm is given for inrush current with initial Tj = 70C. In normal operation, this curve musn t be exceeded. Caution, frequent over load currents will decrease the life expectancy of the SSR. 2 -Itsm rptitif (2) est donn pour des surcharges de courant (Tj initiale=70C). Attention : la rptition de ces surcharges de courant diminue la dure de vie du relais. Warning semiconductor relays don t provide any galvanic insulation between the load and the mains. Always use in conjunction with an adapted circuit breaker with insulation fea- ture or a similar device in order to ensure a reliable insulation in the event of wrong function and when the relay must be insulated from the mains (maintenance if not used for a long duration ...). It is important that the solid state relay is subject to correct installation, maintenance and use conforming to its intended regulations and standards, to the supplier s instructions and to accepted rules of art. Attention les relais semi-conducteurs ne procurent pas d isolation galvanique entre le rseau et la charge. Ils doivent tre utiliss associs un disjoncteur avec proprit de sectionnement ou similaire, afin d assurer un sectionnement fiable en amont de la ligne dans l hypothse d une dfaillance et pour tous les cas o le relais doit tre isol du rseau (maintenance non utilisation sur une longue dure...). Sous rserve d installation, d entretien et d utilisation conformes sa destination, la rglementation, aux normes en vigueur, aux instructions du constructeur et aux rgles de l art. 1 celduc www.celduc.com r e l a i s 5, Rue Ampre BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tl. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tl. +33 (0) 4 77 53 90 19