CHEMTRONICS Technical Data Sheet TDS SIP100P IPA Presaturated Wipes PRODUCT DESCRIPTION TYPICAL PRODUCT DATA AND IPA Presaturated Wipes remove solder paste, PHYSICAL PROPERTIES inks and other contaminants. These highly Boiling Point 174 F Initial effective cleaning wipes are ideal for all Evaporation Rate (butyl acetate=1) <1 general cleaning applications. IPA Presaturated Wipes are well suited for touch- Flash Point (TCC) 68 F up cleaning of automatic printer stencils and Specific Gravity 0.88 cleaning of semi-automatic printer stencils Vapor Pressure 68 F 198 mm Hg during and at the end of production runs. Mild Alcohol Odor IPA Presaturated Wipes contain ultra-pure Solubility in Water Soluble Electronics Grade IPA. The wipes are available in a C-fold wipe contained in a Kauri-Butanol (KB) Number 56 convenient dispensing box or in a tub. VOC* Content: Plastic Safe CARB 70 % Lint free SCAQMD 616 g/L RoHS Compliant Federal 70 % Flammable RoHS Compliant Regular Cleaning Strength California - CARB Electronics Cleaner 75% Compliant Shelflife 2 years *Volatile Organic Compound (VOC) information is calculated on a weight basis using the VOC definition of California Air Resources TYPICAL APPLICATIONS Board (CARB) Consumer Product Regulations, South Coast Air Quality Management District (SCAQMD) Rule 102 and the Federal IPA Presaturated Wipes are engineered for definition published in 40 CFR 51.100(s). cleaning: Screens & Stencils COMPATIBILITY Fiber Optics & Connectors IPA Presaturated Wipes are generally Cables compatible with most materials. As with any Hard-line Coax Cable chemical product, component compatibility Metal & Fiber Optic Cable Splices must be determined on a non-critical area PC Boards prior to use. Control Systems AVAILABILITY USAGE INSTRUCTIONS SIP100P Presaturated Wipes (100/tub) For industrial use only. IPA100B C-Fold Wipes (100/box) Read MSDS carefully prior to use. ENVIRONMENTAL IMPACT DATA SIP100P tub directions: HCFC-141b None HFC None Remove top of container and peel foil seal HCFC-225 None nPB None from top of tub. Pull the first wipe from center of roll and feed it through the opening Hydrochlorofluorocarbons (HCFCs) are regulated in the lid. Replace lid and pull first wipe from under the Montreal Protocol as Class II ozone depleting substances. HCFC-141b is no longer the tub and separate at perforation. Keep produced in the US under this legislation. HCFC-225 container closed to prevent wipes from is planned for production phase-out in 2015. drying out. Hydrofluorocarbons (HFCs) are not currently regulated. IPA100B box directions: EPA has listed n-propyl bromide (nPB) as an Open box and remove wipes from pouch acceptable alternative to ozone depleting substances in metal, precision, and electronics cleaning under found inside box. Pull wipes as needed from Section 612 of the Clean Air Act. the box and close box between uses to prevent wipes from drying out. NOTE: This information is believed to be accurate. It is Cleaning directions: intended for professional end users having the skills General cleaning: Wipe surfaces thoroughly to evaluate and use the data properly. CHEMTRONICS does not guarantee the accuracy of to remove contaminants. When removing the data and assumes no liability in connection with heavy soils, use a clean wipe for final wipe damages incurred while using it. down. Chemtronics is a registered trademark of Chemtronics. All Stencil cleaning: Wipe away residual solder rights reserved. paste until surface is thoroughly cleaned. Repeat with a clean wipe to remove any trace CHEMTRONICS contaminants. 8125 COBB CENTER DRIVE KENNESAW, GA 30152 1-770-424-4888 REV. G (08/13) TECHNICAL & APPLICATION ASSISTANCE DISTRIBUTED BY: Chemtronics provides a technical hotline to answer your technical and application related questions. The toll free number is: 1-800- TECH-401.