V15 TRG30R V SERIES 30W SWITCHING ADAPTER Features * Universal Input Range 90~264VAC * Interchangeable AC Plugs * Meets EN61204-3 Class B and CISPR/FCC Class B * Continuous Short Circuit Protection * Over Voltage Protection * Meet CoC Tier 2 & DoE Level VI (Output Cable Length1800mm) * No Load Power Consumption<75mW Ordering information TRG30RXXXV - XX E XX - XX -BK Model No. DC Plug Type DC Cable Length and Type Color of Overmold Case BE: Blue 01: 720mm 02: 1220mm GY: Gray RD: Red 03: 1800mm 11: 720mm with Ferrite Core PE: Purple OE: Orange 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core * 18AWG / UL1185 * 16AWG / UL1185 for Vo: 5V, 9V VOLTAGE LINE LOAD OUTPUT OUTPUT RIPPLE & NOISE % EFF. (Typ.) MODEL ACCURACY REGULATION REGULATION VOLTAGE CURRENT NOTE 1 NOTE 5 NOTE 2 NOTE 3 NOTE 4 1% TRG30R050V 5V 4.0A 50mVp-p 2% 6% 83.69% 90mVp-p 1% TRG30R090V 9V 3.0A 2% 3% 87.30% 100mVp-p TRG30R120V 12V 2.5A 2% 1% 2% 87.70% 100mVp-p TRG30R150V 15V 2.0A 2% 1% 2% 87.70% 100mVp-p TRG30R180V 18V 1.67A 2% 1% 2% 87.70% 100mVp-p TRG30R240V 24V 1.25A 2% 1% 2% 87.70% Specifications are subject to change without notice. 1 V15 Specifications TRG30R-V Series Derating Curve INPUT SPECIFICATIONS: 100% Voltage ....................................................... 90~264Vac 80% Frequency ...... 47 to 63Hz 60% Input Current ........................................................ 0.8A max. 20LFM(Natural Convection) Inrush Current Cold start 25. 100A max. 240Vac 40% Leakage Current . 0.25mA max. 20% OUTPUT SPECIFICATIONS: 0% Hold-up Time 10ms typ. 115Vac -20 -10 0 10 20 30 40 50 60 70 80 Short Circuit Protection . Hiccup Mode (Auto Recovery) o Ambient Temperature( C) Over Voltage Protection .................. Latch GENERAL SPECIFICATIONS: NOTE: Isolation Input to output ( 4,242VDC) 1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple & Noise measuring 20MHz BW. Operating Temperature ................................. -20 ~ 60(see Drating Curve) Storage Temperature .................. -20~85 2. Voltage setpoint at 60% full load. Humidity ................... 93% RH max. Non condensing 3. Line regulation is measured from 100Vac to 240Vac with full load. Cooling .. Natural Convection 4. Load regulation is measured from 60% to full load and from 60% to Switching Frequency .. 70KHz Typical 20% load (60% +/- 40% load). 5. Average Efficiency measured at 25%,50%,75%,100% load and input. MTBF . MIL-HDBK-217F, GB, 25 /115VAC 200Khrs min. Altitude 5000m voltage is 115Vac / 230Vac. Dimensions .. 4.243x2.267x1.319 inches (107.77x57.60x33.50mm) Weight . 300g(0.66 Pounds) SAFETY AND EMC: Emission and Immunity .... EN61204-3, EN61000-3-2,EN61000-3-3 FCC CFR Title 47 Part 15 Subpart B Safety .... Class II, IEC60950-1, UL60950-1, EN60950-1 Mechanical Specification All Dimensions are in inches(mm) Tolerance:Inches:X.XXX0.02 Millimeters:X.XX0.5 2.267 57.60 DC Plug type: V+ ) V- DC Plug :Right Angle(5.52.1) L12mm 18AWG1800mm + - 70.866 1800.00 1.969 50.00 1.494 37.95 0.492 12.50 0.002 0.05 0.720 18.30 0.002 0.05 0.874 22.20 0.005 0.13 0.157 4.00 0.248 6.30 Typical at 25C, nominal line and 75% load, unless otherwise Specified 2 1.535 39.00 4.243 107.77 0.689 17.50 0.019 0.50 0.630 16.00 1.319 33.50 1.283 32.60 0.685 17.40 0.027 0.70 1.102 28.00 Rated Load(%) 0.748 19.00 0.019 0.50 0.988 25.10 0.669 16.99 0.011 0.30 0.342 8.70 0.019 0.50 1.240 31.48 1.139 28.93