Small Size Good dvdt EN60252-1 rated FEATURES AC Application Motor Run AC/DC Motor Controls APPLICATIONS Switching Power Supplies -40C to +100C without approvals Operating Temperature Range -25C to +85C with approvals +10% at 1 kHz, 25C Capacitance Tolerance +5% optional Code A04 A03 A02 A01 A05 WVDC 370 500 600 800 1200 Peak, AC voltage (50/60 Hz) SVDC 470 625 750 1050 1500 VAC 160/200 250/320 320/400/430 400/432/500 500/600 Dissipation Factor (MAX) C<2.2uF 2.2<C<15uF 15<C<22uF C>22uF Tan .06% .1% .12% .15% at 1 kHz and 25C Insulation Resistance 10000 M, C<1uF 25C (<70% RH)for 1 minute 3000 MxuF, C>1uF at 100VDC applied Self Inductance <1 nano-Henry per mm of lead spacing Terminal to Terminal Terminal to Case 160% of VAC for 60 Seconds and 25C Dielectric Strength 3kVAC (50/60 Hz) applied or 200% VAC applied for 60 Seconds and for 60 Seconds and 25C 25C for EN 60252-1 approval 56 days with no voltage applied at +40C and 93%(+2%) relative humidity Capacitance Change <+2% of initially measured value Damp Heat Dissipation Factor <.001 at 1 kHz for C>0.1uF Insulation Resistance >50% of minimum specified value WVDC Class A Class B Class C Class D Hours 30000 10000 3000 1000 Reliability test 6000 2000 600 200 9 500/10 component hours Failure quota metallized film Construction Coating Flame Retardant Plastic box with epoxy end fill(UL94V0) Lead terminations Lead free tinned copper leads Sep-20 Voltage WVDC/ SVDC VAC Agency standard Description Certification code Approval UL 810 Construction only (E192977) CSA 22.2 190-M-1985 A04 350/ 425 160 30000 hrs. Continuous Service Class A 200 3000 hrs. Continuous Service Class C UL 810 Construction only (E192977) CSA 22.2 190-M-1985 A03 500/ 625 30000 hrs. Continuous Service Class A 275 10000 hrs. Continuous Service Class B 320 3000 hrs. Continuous Service Class C UL 810 Construction only (E192977) CSA 22.2 190-M-1985 A02 600/ 750 320 EN60252-1 30000 hrs. Continuous Service Class A 400 EN60252-1 10000 hrs. Continuous Service Class B 430 EN60252-1 1000 hrs. Continuous Service Class D UL 810 Construction only (E192977) CSA 22.2 190-M-1985 A01 800/ 1050 400 EN60252-1 30000 hrs. Continuous Service Class A 430 EN60252-1 10000 hrs. Continuous Service Class B 500 EN60252-1 3000 hrs. Continuous Service Class C UL 810 Construction only (E192977) CSA 22.2 190-M-1985 A05 1200/ 1500 500 10000 hrs. Continuous Service Class B 600 3000 hrs. Continuous Service Class C Terminal Style Selection Lead Spacing S5 5mm+/-1mm Solid tinned copper wire L 26.5 32 39.5 42.5 L30 30mm+/-5mm Solid tinned copper wire S 22.5 27.5 35 37.5 CXX Customer specified Insulated Solid tinned copper wire d 0.8 0.8 0.8 1.0 (50-200mm Lead length) MXX Customer specified Insulated Stranded tinned copper wire (50-200mm Lead length) Style S5 Style L30 Style CXX, MXX Sep-20