AC-DC Power Supplies DIN Rail Type Power Safety EMI OCP OVP World wide Inrush Remote Factor Approvals current ON/OFF Correction limiting KH-series Feature CE marking For DIN (35mm) rail products Low Voltage Directive Wide operating ambient temperature range RoHS Directive I/O terminal has 2 types, Euro Style and Barrier Blocks Style Built in overcurrent protection, overvoltage protection circuits EMI -KHEA30F/60F/90F, KHNA30F/60F/90F Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, Low power consumption at no load VCCI-B Complies with SEMI F-47 (Derating is required) EMS Compliance : EN61204-3, EN61000-6-2 -KHEA120F/240F/480F, KHNA120F/240F/480F Built in remote ON/OFF EN61000-4-2 Built in signal output for confirming output voltage EN61000-4-3 Complies with SEMI F-47 EN61000-4-4 EN61000-4-5 EN61000-4-6 Safety agency approvals EN61000-4-8 UL60950-1, UL508, C-UL (CSA60950-1), EN60950-1, EN61000-4-11 ANSI/ISA12.12.01, ATEX Complies with DEN-AN 5-year warranty (refer to Instruction Manual) June 29, 2020 KH-1Ordering information AC-DC Power Supplies DIN Rail Type KHO A 30 F -OO -O KHEA/KHNA30F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R KHE Euro style I/O terminals NAC-04-472-D KHN Barrier blocks style I/O terminals 2 Single output 3 Output wattage 4 Universal input UL508 5 Output voltage 6 Option High voltage pulse noise type : NAP series C : with Coating Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL KHEA/KHNA30F-5 KHEA/KHNA30F-12 KHEA/KHNA30F-24 MAX OUTPUT WATTAGE W 25 27.6 31.2 DC OUTPUT 5V 5A 12V 2.3A 24V 1.3A SPECIFICATIONS MODEL KHEA/KHNA30F-5 KHEA/KHNA30F-12 KHEA/KHNA30F-24 *11 VOLTAGE V AC85 - 264 1f (Refer to Derating) or DC88 - 370 ACIN 115V 0.45typ 0.50typ 0.55typ CURRENT A ACIN 230V 0.30typ 0.30typ 0.35typ FREQUENCY Hz 50 / 60 (45 - 440) or DC INPUT ACIN 115V 84.0typ 87.0typ 88.5typ EFFICIENCY % ACIN 230V 85.5typ 88.5typ 89.5typ ACIN 115V 18typ (Io=100% (at cold start Ta=25C) INRUSH CURRENT A *1 ACIN 230V 35typ (Io=100% (at cold start Ta=25C) LEAKAGE CURRENT mA 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) VOLTAGE V 5 12 24 CURRENT A 5.0 2.3 1.3 PEAK CURRENT A - - - *2 LINE REGULATION mV 20max 48max 96max LOAD REGULATION mV *2 80max 100max 150max 0 to +70C 150max 150max 150max RIPPLE mVp-p *3 -20 - 0C 300max 300max 300max *4 *4 *4 Io=0 - 30% 300max 300max 300max 0 to +70C 180max 180max 180max OUTPUT *3 RIPPLE NOISE mVp-p -20 - 0C 360max 360max 360max *4 *4 *4 Io=0 - 30% 360max 360max 360max 0 to +70C 50max 120max 240max TEMPERATURE REGULATION mV -20 to +70C 60max 150max 290max DRIFT mV *5 20max 48max 96max START-UP TIME ms 200typ (ACIN 115V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 4.50 to 5.50 10.80 to 13.20 22.50 to 28.50 OUTPUT VOLTAGE SETTING V 5.00 to 5.15 12.00 to 12.48 24.00 to 24.96 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically *10 PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION V 6.30 to 7.60 13.80 to 16.80 30.00 to 36.00 OTHERS DC OK LAMP LED (Green) INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min At Room Temperature ISOLATION INPUT-PE AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min At Room Temperature OUTPUT-PE AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min At Room Temperature OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing), Type tested for -40C start-up (Refer to Derating) STORAGE TEMP.,HUMID.AND ALTITUDE -30 to +85C, 20 - 90%RH (Non condensing) ENVIRONMENT 2 *8 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis (Packing state) * AC input UL60950-1, C-UL (CSA60950-1), EN60950-1, UL508 (NEC Class2 per UL1310), ANSI/ISA12.12.01, ATEX, Complies with DEN-AN AGENCY APPROVALS SAFETY AND DC input UL60950-1, C-UL (CSA60950-1), EN60950-1 NOISE CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B REGULATIONS *6 *9 HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) Not built-in to active lter) *7 CASE SIZE 22.5X75X90mm (WXHXD) 0.89X2.95X3.54 inches OTHERS WEIGHT 165g max COOLING METHOD Convection *1 The value is primary surge. The current of input surge to a built-in EMI/EMC Filter(0.2ms or less)is *6 Please contact us about another class. excluded. *7 Case size contains neither the umbo. *2 Please contact us about dynamic load and input response. *8 Only as standard mounting orientation (A). Refer to the Assembling and Installation Method. *3 This is the value that measured on measuring board with capacitor of 22mF and 0.1mF at 150mm from If install other than standard mounting orientation (A), please x the power supply for withstand the output terminal. vibration and impact. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *9 When two or more units are operating it may not comply with the IEC61000-3-2. Please refer to the instruction manual 1.7. *10 If the over current protection circuit operates continuously, the output voltage shut down. Refer to Ripple and ripple noise spec is change at Io=0 to 30% by burst operation. the instruction manual 1.3. *4 In case of operating under 0C ambient temperature, the value is two times of specication at 0 to *11 Under low DC input voltage below DC110V, the temperature derating -1C/V or the output power 30% load factor. derating -1%/V are required. *5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the * To meet the specications. Do not operate over-loaded condition. input voltage held constant at the rated input/output. * A sound may occur from power supply at light or peak loading. June 29, 2020 KH-2