AC-DC Power Supplies DIN Rail Type Power Safety EMI OCP OVP World wide Inrush Factor Approvals current Correction limiting KL-series Feature EMI For DIN (35mm) rail products Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, Wide operating ambient temperature range VCCI-B I/O terminal has 2 types, Euro Style and Barrier Blocks Style Built in overcurrent protection, overvoltage protection circuits EMS Compliance : EN61204-3, EN61000-6-2 Complies with SEMI F-47 (refer to Instruction Manual 1.1) EN61000-4-2 EN61000-4-3 Safety agency approvals EN61000-4-4 UL60950-1, UL508, C-UL (CSA60950-1), EN60950-1 EN61000-4-5 Complies with DEN-AN EN61000-4-6 EN61000-4-8 EN61000-4-11 5-year warranty (refer to Instruction Manual) CE marking Low Voltage Directive RoHS Directive July 03, 2020 KL-1Ordering information AC-DC Power Supplies DIN Rail Type KLO A 120 F -OO -O KLEA/KLNA120F 1 2 3 4 5 6 1 Series name Example recommended EMI/EMC filter R KLE : Euro Style I/O Terminals NAC-04-472-D KLN : Barrier Blocks Style I/O Terminals 2 Single output 3 Output wattage 4 Universal input UL508 5 Output voltage 6 Option High voltage pulse noise type : NAP series C : with Coating Low leakage current type : NAM series N2 : Screw mounting * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL KLEA/KLNA120F-24 KLEA/KLNA120F-48 MAX OUTPUT WATTAGE W 120 120 DC OUTPUT 24V 5A 48V 2.5A SPECIFICATIONS MODEL KLEA/KLNA120F-24 KLEA/KLNA120F-48 VOLTAGE V AC85 - 264 1f (Refer to Derating) *9 ACIN 115V 1.2typ CURRENT A ACIN 230V 0.6typ FREQUENCY Hz 50 / 60 (45 - 66) ACIN 115V 86.5typ EFFICIENCY % INPUT ACIN 230V 88.0typ ACIN 115V 0.98typ POWER FACTOR ACIN 230V 0.90typ INRUSH CURRENT A ACIN 115V 20typ (Io=100%)(at cold start Ta=25C) *1 ACIN 230V 40typ (Io=100%)(at cold start Ta=25C) LEAKAGE CURRENT mA 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) VOLTAGE V 24 48 CURRENT A 5 2.5 *2 *8 *8 LINE REGULATION mV 96max (Io=30-100%) 192max (Io=30-100%) LOAD REGULATION mV *2 150max (Io=30-100%) *8 300max (Io=30-100%) *8 0 to +70C 150max 150max RIPPLE mVp-p *3 -20 - 0C 240max 240max Io=0 - 30% 500max 650max 0 to +70C 180max 180max *3 OUTPUT RIPPLE NOISE mVp-p -20 - 0C 300max 300max Io=0 - 30% 500max 650max 0 to +70C 240max 480max TEMPERATURE REGULATION mV -20 to +70C 290max 600max DRIFT mV *4 96max 192max START-UP TIME ms 500typ (ACIN 115V, Io=100%) HOLD-UP TIME ms 20typ (ACIN 115V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE V 21.60 to 26.40 43.20 to 52.80 OUTPUT VOLTAGE SETTING V 24.00 to 24.96 48.00 to 49.92 OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION V 27.60 to 33.60 54.00 to 67.20 OTHERS DC OK LAMP LED (Green) INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min At Room Temperature ISOLATION INPUT-PE AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min At Room Temperature OUTPUT-PE AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min At Room Temperature OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +70C, 20 - 90%RH (Non condensing), Type tested for -40C start-up (Refer to Derating) STORAGE TEMP.,HUMID.AND ALTITUDE -30 to +85C, 20 - 90%RH (Non condensing) ENVIRONMENT 2 *7 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60 minutes along Z axis (Non operating, mounted on DIN Rail) 2 IMPACT 196.1m/s (20G), 11ms, once each X, Y and Z axis (Packing state) AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, UL508, Complies with DEN-AN SAFETY AND CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B NOISE REGULATIONS *5 HARMONIC ATTENUATOR Complies with IEC61000-3-2 Class A) *6 CASE SIZE 38X124X117mm (WXHXD) 1.5X4.88X4.61 inches OTHERS WEIGHT 580g max COOLING METHOD Convection *1 The value is primar y surge. The current of input surge to a built-in EMI/EMC *4 Drift is the change in DC output for an eight hour period after a half-hour supply for withstand the vibration and impact. Filter(0.2ms or less)is excluded. warm-up at 25C, with the input voltage held constant at the rated input/ *8 Burst operation at 30% load or less. *2 Please contact us about dynamic load and input response. output. *9 Please contact us about DC input voltage. *3 This is the value that measured on measuring board with capacitor of 22mF *5 Please contact us about another class. * To meet the specications. Do not operate over-loaded condition. and 0.1mF at 150mm from output terminal. *6 Case size contains neither the umbo. * A sound may occur from power supply at light or peak loading. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to *7 Only as standard mounting orientation (A). Refer to Assembling and KEISOKU-GIKEN: RM103). Installation Method . Please refer to the instruction manual 1.5. If install other than standard mounting orientation (A), please x the power July 03, 2020 KL-2