Product Information

LWRS440A

LWRS440A electronic component of Crouzet

Datasheet
Electromechanical Relay Plug-In Mount, 415VAC/440VAC, Phase Control Relay

Manufacturer: Crouzet
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

2: USD 62.4487 ea
Line Total: USD 124.9

11 - Global Stock
Ships to you between
Fri. 17 May to Thu. 23 May
MOQ: 2  Multiples: 1
Pack Size: 1
Availability Price Quantity
8 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1

Stock Image

LWRS440A
Crouzet

1 : USD 174.2869

11 - WHS 2


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 2
Multiples : 1

Stock Image

LWRS440A
Crouzet

2 : USD 62.4487
5 : USD 54.2587

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Brand
Tradename
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
24678182 electronic component of Crouzet 24678182

MANUAL ACTUATED VALVES
Stock : 0

79452123 electronic component of Crouzet 79452123

Crouzet RG LNG PLAST RLR LVR-COMP VLV
Stock : 0

26231941 electronic component of Crouzet 26231941

Motor Start Capacitors & Motor Run Capacitors Capacitor 0,10uf/10%/700VDC
Stock : 1

27358015 electronic component of Crouzet 27358015

Motor Drives SHIELDED CABLE CANOPEN SQ57 & SQ75 (FEMALE CONNECTOR M12 - 5 PINS - LENGTH : 3000 MM)
Stock : 0

26231711 electronic component of Crouzet 26231711

Motor Start Capacitors & Motor Run Capacitors Capacitor 8,2uf/10%/100VDC
Stock : 1

24678173 electronic component of Crouzet 24678173

Switch Access Push Button Switch Round Actuator
Stock : 1

26231801 electronic component of Crouzet 26231801

Motor Start Capacitors & Motor Run Capacitors Capacitor 0,33uf/10%/400VDC
Stock : 1

26231909 electronic component of Crouzet 26231909

Motor Start Capacitors & Motor Run Capacitors Capacitor 0,22uf/5%/630VDC
Stock : 1

79210372 electronic component of Crouzet 79210372

AC, DC & Servo Motors Limit switch accessory, for 83990Ex Series, RLR LVR FOR SP3969
Stock : 0

26532001 electronic component of Crouzet 26532001

Relay Sockets & Fixings SSR Accessory, Assembly Kit For Heatsink 26532764N
Stock : 1

Image Description
AZ2510P2-1A-24D electronic component of Zettler AZ2510P2-1A-24D

Electromechanical Relay SPST-N
Stock : 1

RPM12B7 electronic component of Schneider RPM12B7

Industrial Relays PLUG-IN RELAY 250V 1 5A RPM
Stock : 1

2966919 electronic component of Phoenix Contact 2966919

Industrial Relays PLC-RSC- 12DC/21AU RELAY PN 651-2961163
Stock : 1

RSB2A080RD electronic component of Schneider RSB2A080RD

Industrial Relays PLUG-IN RELAY 250VAC 8A RSB
Stock : 0

RXM2AB3F7 electronic component of Schneider RXM2AB3F7

Industrial Relays Plug-in Relay 250V 10A RXM+LED NO MAN
Stock : 1

2902955 electronic component of Phoenix Contact 2902955

Industrial Relays PLC-RSC-24DC/21 ATEX
Stock : 1

2966223 electronic component of Phoenix Contact 2966223

Industrial Relays PLC-RSC-24DC/1/SEN
Stock : 1

R4N-2014-23-5012-WT electronic component of Relpol R4N-2014-23-5012-WT

Relay: electromagnetic; 4PDT; Ucoil:12VAC; 6A/250VAC; 6A/24VDC
Stock : 0

RM84-2012-25-5230 electronic component of Altech RM84-2012-25-5230

Industrial Relays Miniature relay, DPDT
Stock : 1

RM84-2012-25-5110 electronic component of Altech RM84-2012-25-5110

Industrial Relays relay 110VAC coil 50/60HZ
Stock : 0

CONTROLS CONTROLS WRL SERIES PHASE CONTROL RELAY UL listed CSA recognized Monitors Phase Sequence Loss of Any Phase even if Induced Voltage reaches 95% of Nominal Voltage Under Voltage Detection Trip Delay Timer Built-in LED Relay Status Indicator 2 MODE OF OPERATION: The WRL Phase Control Relay monitors the sequence loss or reversal of three phase power supplies. The output relay is energized when the phase sequence is correct and the phase voltage is above the voltage threshold set by the front knob. The output relay will de-energize after 2 seconds (built-in timer) when the phase voltage drops under the voltage threshold or when phase sequence is lost. The WRL Series is available in three voltage ranges: 230 VAC, 380 VAC and 480 VAC. SPECIFICATIONS: WIRING DIAGRAM: Input Power . 3 x 230 (50/60 Hz) 3 x 380 (50/60 Hz) 3 x 480 (50/60 Hz) Maximum voltage 3 x 280 VAC 3 x 420 VAC 3 x 530 VAC Minimum voltage 3 x 160 VAC 3 x 260 VAC 3 x 340 VAC Threshold adjustment range . 160 to 230 VAC 260 to 380 VAC 340 to 480 VAC Max power consumption 2 VA Dial accuracy . 10% Temperature De-rating 0.04%/C Dead Band . 4% of 480 VAC Response Time 300 ms on Make 2 sec on Break Output SPDT Version (WRL) Series) . 10 Amp 250 VAC Max. power consumption 2000 VA Max. voltage 250 VAC 7 Electrical life 2 x 10 operations 6 Mechanical life 1 x 10 operations Operating temperature -10C to +60C Weight . 3.5 oz. (100g) ORDERING INFORMATION: D WRL 230A MOUNTING SERIES INPUT POWER INPUT POWER MOUNTING SERIES 230A = 3 x 230 VAC L = 11 pin plug-in WRL = SPDT Version 380A = 3 x 380 VAC P = 8 pin plug-in 480A = 3 x 480 VAC Products and specifications subject to change without notice. Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2/81CONTROLS CONTROLS WRA SERIES PHASE CONTROL RELAY UL listed CSA recognized (220 VAC Version Only) Monitors Phase Sequence Loss of Any Phase even if Induced Voltage reaches 95% of Nominal Voltage LED Relay Status Indicator SPDT 10 Amp Relay Output MODE OF OPERATION: WIRING DIAGRAM: R S T R T S R S T R S NR ST T R = L1 S = L2 T = L3 R D1 11 RS T The WRL Phase Control Relay monitors the sequence loss or reversal of three phase power supplies. The output relay is energized when the phase sequence is correct and is de-energize when the phase 12 14 sequence is wrong or one phase is lost. It monitors the symmetry of 3 voltages and a loss of phase even when the voltage is reinjected through a machine. The rate of asymmetry is controlled between 5% STOP and 15% by a top mounted potentiometer. d1 U V W SPECIFICATIONS: START Input Power Directly 3 x 220 60 Hz from controlled voltage 15% 3 x 380 60 Hz 3 x 440 60 Hz M Power consumption . 3 VA at 220 V Output . SPDT relay Contact material . AgCdO Maximum Loading . 10 AC resistive 8A DC inductive Maximum switching voltage 250 VAC 250 VDC Relay max. power rating . 220 VA 80 W DWRA 11 12 14 R S T 6 Mechanical life of relay 30 x 10 operations 5 Electrical life of relay 2 x 10 operations at 2200VA resistive load LWRA 1 4 3 5 6 7 Operating temperature +14F to +140F -10C to +60C Weight . 7 oz. (200g) PWRA 1 2 8 3 4 5 Note: The alarm threshold adjustment is 5% to 15% of asymmetry between the phases. The initial response time is .1 seconds at 5% asymmetry and 1 second at 15% after input power is applied. When a phase loss or failure occurs, the off delay response time is 100 ms. ORDERING INFORMATION: L WRA 380 A MOUNTING SERIES INPUT POWER INPUT POWER MOUNTING SERIES 220A = 3 x 220 VAC D = DIN-rail mounting WRA 380A = 3 x 380 VAC L = 11 pin plug-in 440A = 3 x 415/440 VAC P = 8 pin plug-in Products and specifications subject to change without notice. Order/Technical Support Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 2/82

Tariff Desc

8536.49.00 TC17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC8909066 RELAYS having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mmx30mmx27mm

8536.49.00 TC9613322 RELAYS low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24mm
(b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8AAC

8536.49 TC8906734 RELAYS having ALL of the following:
(a) one, two or three contacts
(b) maximum continuous contact current rating of NOT less than 15A
(c) maximum contact voltage rating of NOT less than 380V
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC1122469 RELAYS having an operating voltage NOT exceeding 250volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC8534635 RELAYS cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5A (AC or DC);
(b) switching voltage NOT exceeding 250V (AC or DC);
(c) body dimensions NOT exceeding 31mm x36mm x19mm

8536.49 TC8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8538.90.90 08 .. For programmable controllers Other Free
Crouzet Automation
Crouzet CO BEI Systems and Sensor Company
Crouzet Control
Crouzet Controls
CROUZET MOTOR TECHNOLOGIES
Crouzet Motors
CROUZET SSR
CROUZET SWITCH TECHNOLOGIES
Crouzet Switches
Crouzet USA

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted