Additional Resources: Product Page 3D Model date 04/28/2021 page 1 of 5 SERIES: VGD-35 DESCRIPTION: AC-DC POWER SUPPLY FEATURES universal input voltage range (85~264 Vac) provides dual outputs independently isolated short circuit, over current and over voltage protections safety certified: IEC/EN/UL 62368 designed to meet: IEC/EN/UL 60335 class B EMI performance, meets CISPR32 / EN 55032 RoHS output output output ripple efficiency MODEL 1 2 voltage current power and noise min max max max typ (Vdc) (A) (A) (W) (mVp-p) (%) 5 0.4 4 80 VGD-35-D512 32 81 12 0.1 1 150 5 0.22 2.2 80 VGD-35-D524 35 83 24 0.1 1 150 Note: 1. Maximum total combined power. 2. Ripple & noise are measured at 20 MHz BW with 47 F aluminum electrolytic capacitor and 0.1 F ceramic capacitor on the output. PART NUMBER KEY VGD-35 - DXXX Base Number Output Voltage cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGD-35 DESCRIPTION: AC-DC POWER SUPPLY date 04/28/2021 page 2 of 5 INPUT parameter conditions/description min typ max units 85 264 Vac voltage 120 373 Vdc frequency 47 63 Hz 115 Vac 0.75 A input current 230 Vac 0.5 A 115 Vac, full load, cold start 30 A inrush current 230 Vac, full load, cold start 50 A OUTPUT parameter conditions/description min typ max units Vo1, at full load 0.5 % line regulation Vo2, at full load 1.5 % Vo1, 10% ~ 100% (balanced load) 0.5 % load regulation Vo2, 10% ~ 100% (balanced load) 5.0 % temperature coefficient 0.03 %/C 115 Vac, full load 5 ms hold-up time 230 Vac, full load 30 ms 1 adjustability adjustable with built-in trim pot 4.75 5.50 Vdc Vo1, full load range 2.0 % output voltage accuracy Vo2, full load range 8.0 % Note: 1. Adjustment of 5 V output only. PROTECTIONS parameter conditions/description min typ max units over voltage protection output clamped 5.75 6.75 V overload protection hiccup mode, automatically recovers 110 220 % short circuit protection hiccup, continuous, self-recovery ( ) SAFETY & COMPLIANCE CONTINUED parameter conditions/description min typ max units output to output 500 Vdc input to output 3,000 Vac isolation voltage input to ground 2,000 Vac output to ground 500 Vac isolation resistance input to output at 500 Vdc at 25C 100 M IEC/EN/UL62368 safety approvals (designed to meet IEC/EN/UL60335) safety class Class I conducted emissions CISPR32/ EN55032 Class B radiated emissions CISPR32/ EN55032 Class B ESD IEC/EN61000-4-2, Contact 6KV / Air 8KV, perf. Criteria A radiated immunity IEC/EN61000-4-3, 10V/m, perf. Criteria A EFT/burst IEC/EN61000-4-4, 2KV, perf. Criteria A surge IEC/EN 61000-4-5, Line to Line 2KV / Line to Ground4KV, perf. Criteria A conducted immunity IEC/EN61000-4-6, 10 Vrms, perf. Criteria A cui.com