X-On Electronics has gained recognition as a prominent supplier of SYLOG-USB-2 data logging & acquisition across the USA, India, Europe, Australia, and various other global locations. SYLOG-USB-2 data logging & acquisition are a product manufactured by Display Visions. We provide cost-effective solutions for data logging & acquisition, ensuring timely deliveries around the world.

SYLOG-USB-2

SYLOG-USB-2 electronic component of Display Visions
Images are for reference only
See Product Specifications
Part No. SYLOG-USB-2
Manufacturer: Display Visions
Category: Data Logging & Acquisition
Description: Data Logging & Acquisition USB Data Logger Temp and Humidity
Datasheet: SYLOG-USB-2 Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 128.7058 ea
Line Total: USD 128.71

Availability - 0
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Wed. 05 Jun to Fri. 07 Jun

MOQ : 1
Multiples : 1
1 : USD 117.4696
10 : USD 112.7479
100 : USD 108.998
100000 : USD 108.9855

     
Manufacturer
Product Category
Product
Type
Display Type
Connection Method
Interface Type
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Part-Description
Stock Image EA 0FP129-6SW
LCD Graphic Display Modules & Accessories Mounting bezel BLK 128x64 Anodized
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA EPA60-A
Electronic Paper Displays - ePaper 6 in. e-Paper gray scale
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA EVALEDIPTFT57
EA eDIPTFT57 LCD Display Display Evaluation Board
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA KIT160-6LWTP
LCD Graphic Display Modules & Accessories Blue/White Contrast RS-232 Snap-In Kit
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA SER164-NLW
Display: LCD; alphanumeric; STN Negative; 16x4; blue; LED; 4.75mm
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA SER202-NLW
Display: LCD; alphanumeric; STN Negative; 20x2; blue; LED; 116x37mm
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA SYLOG-USB-3
USB DATA LOGGER FOR VOLT
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA LED66X40-A
LED Backlighting Amber LED Backlight for EA DOGM204-A
Stock : 46
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA LED55X31-W
LED Backlighting White LED Backlight For DOG-M Series
Stock : 1523
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image EA SER204 NLED 5VDC
Display: LCD; alphanumeric; 20x4; 42.1x98x29mm; LED; PIN: 16; 5VDC
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image ND-6018
Datalogging & Acquisition 8CH THERMOCOUPLE INPUT MODULE
Stock : 6
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image DLP-232PC
Datalogging & Acquisition MINI USB MICROCONTR- OLLER MODULE
Stock : 144
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image USB-4704-AE
Datalogging & Acquisition 48kS/s, 14-bit, Multi-function USB Module
Stock : 63
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image PCI-1760U-BE
Datalogging & Acquisition 8-ch Relay & 8-ch IDI Universal PCI Card
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image HT20-2100M0
Logger; Mounting: for wall mounting; IP20; 0÷40°C; 150x100x28mm
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image HT20IOT-20MQM0
Logger; Mounting: for wall mounting; IP20; 0÷40°C; 150x100x28mm
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SM61IOT-1200M0
Industrial module: data logger; 85÷253VAC; 90÷300VDC; IN:2
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image KEW7197
Test acces: adapter; Works with: KEW5020
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image KEW8309
Conform to: EN61010 600VCAT III; Test acces: voltage sensor
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image SpotBotBLE
Data Logging & Acquisition Single Unit SpotBotBLE
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
We proudly offer the SYLOG-USB-2 Data Logging & Acquisition at competitive prices in the United States, Australia, India, Europe and more. By maintaining strong relationships with manufacturers and optimizing our operations, we provide significant savings to our customers. Customer satisfaction is at the heart of our business. Our knowledgeable and friendly customer service team is always ready to assist you with any inquiries or issues. From product selection to after-sales support, we are dedicated to providing our customers with a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why we are the top choice for the SYLOG-USB-2 Data Logging & Acquisition.

EL-USB-2 Temperature, Humidity and Dew Point Data Logger -35 to +80C (-31 to +176F) and 0 to 100%RH measurement range Stores over 16,000 readings for both temperature and humidity EasyLog software available as a free download Logging rates between 10 seconds and 12 hours Immediate and delayed logging start User-programmable alarm thresholds for both temperature and humidity Status indication via red/green LEDs Environmental protection to IP67 This standalone data logger measures and stores over 16,000 temperature and humidity readings from -35 to +80C (-31 to +176F) and 0 to 100%RH range at a resolution of 0.5C (1F) and 0.5%RH. The user can easily set up the logger and view downloaded data by plugging the data logger into a PCs USB port and using the free EasyLog software. Data, including calculated dew point, can then be graphed, printed and exported to other applications for detailed analysis. The data logger is supplied with a lithium metal baertt y, giving up to three years logging life. The logger is protected against ingress from water and dust to IP67 standard when the cap is fitted. SPECIFICATIONS ACCESSORIES Temperature Measurement range -35C to 80C (-31F to 176F) BAT 3V6 1/2AA Replacement baertt y Internal resolution 0.5C (1F) EL-DataPad Handheld data logger Accuracy (overall error)* 0.55C (1.04F) typical (5 to 60C) programmer & collector Long term stability <0.02C (0.04F) / year Relative Humidity Measurement range 0 to 100%RH INCLUDED IN THE BOX Internal resolution 0.5%RH Accuracy (overall error)* 2.25%RH typical (20 to 80%RH) BAT 3V6 1/2AA Baertt y Long term stability <0.25%RH / year EL-USB WALL BRACKET Mounting Bracket Dew Point Accuracy (overall error)* 1.7C typical (-35 to 80C, 40 to 100%RH) Logging rate User selectable between 10 seconds & 12 hours Operating temperature range -35 to +80C (-31 to +176F) Baertt y life 3 years (at 25C and 1 minute logging rate) Readings 16,382 temperature, 16,382 relative humidity Dimensions 108 x 25 x 22mm (4.25 x 0.98 x 0.86) * The overall error takes in to account the sensor accuracy (as shown on page 3) and the resolution of the data logger CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment www.lascarelectronics.com which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information, please see www.lascarelectronics.com. Issue 14 08/2016 N.R Page 1 of 4EL-USB-2 Temperature, Humidity and Dew Point Data Logger EL-WIN-USB Lascars EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 & 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: Logger name Measurement parameter (C or F) Logging rate (user selectable between 10 seconds and 12 hours) High and low alarms Immediate and delayed logging start Download the latest version of the software free of charge from www.easylogusb.com LED STATUS INDICATION The EL-USB-2 features two green/red LEDs, one to represent temperature measurement and the other to represent humidity measurement. Each is clearly marked on the logger. To save power, the status indication alternates between the two channels every 10 seconds. First you will see the status of the temperature channel and 10 seconds later you will see the status of the RH channel and so on. 10 seconds later RH% C (F) RH% C (F) In normal operation the green LED will flash, but will change to red if an alarm condition has been triggered. Using EL-WIN-USB it is possible to set the alarm to remain active even if the reading has returned to normal, in which case the alarm LED will continue to flash red. This Hold feature in the software ensures the user is notified that at some point an alarm level has been exceeded, without needing to download the data. Green double flash The data logger is not currently logging, but is primed to start at a later date and time (delayed start) Green single flash The data logger is currently logging. No alarm on the channel Red single flash The data logger is currently logging. Low alarm on the channel Red double flash The data logger is currently logging. High alarm on the channel Green triple flash The data logger is full and has stopped logging. No alarm on the channel Red triple flash The data logger is full and has stopped logging. Alarm (high, low or both) on the channel No LEDs flash The data logger is stopped, the baertt y is empty or there is no baertt y Dual Red flash (every 60 seconds) The data logger baertt y is running low as its voltage has dropped below 2.9V www.lascarelectronics.com Issue 14 08/2016 N.R Page 2 of 4

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free
DISPLAY VISIONS
Electronic Assembly
Electronic Assembly GmbH

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted